ECOFER UVC09/UVC12/UVC18/UVC24                                User manual                                                                                                                                                                                   

 

 

 

 
 

Electrical safety

 

Grounding:

 This room air conditioner must be grounded. Grounding reduces the risk of electric shock by providing an 

escape wire for the electric current. If the power cord has a grounding plug with a grounding wire, plug it 
into an outlet that is properly installed and grounded. If the power cord has not a grounding plug with a 
grounding wire, the grounding wire must connect the breaker that is properly installed and grounded. 

 

Warning

: Improper use of the grounding plug or breaker can result in a risk of electric shock. Call a qualified electrician 

if you don’t understand the grounding instruct

ions or if you are not sure if the air conditioner is properly grounded. If 

the wall outlet or breaker is not grounded, please contact an electrician to have it replaced with a properly grounded 
outlet or breaker. 

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. 

Adapter plug: We strongly advise against using an adapter plug or breaker. 
 

Operating conditions 
 

1. Temperature: T1 instance: -7

~43

 (16

~43

 in cooling-only type) 

    T3 instance: -7

~52

(16

~52

 in cooling-only type) 

If  the  unit  runs  beyond  the  temperature  for  a  long  time,  it  may  cause  cooling  capacity  to  decrease  or  protector  to 
work. 
2. Relative humidity: <80% 
If the unit runs beyond the humidity range, condensate may be formed near blade and outlet of 

air conditioner. It’ s 

normal. 
3. In heating operation, strange smell may come from the unit. It is Normal phenomenon. 
4. The performance parameters refer to name plate. 
5. The waterproof level of indoor unit is IPX0. Do not use it in the laundry or bathroom. 

6. The outdoor unit can’ t be installed i

n a closed area. 

7. Fuse:50T T3.15AL250V or F3.15AL250V, rated current:3.15A. 
 

Tips

 

 

Install the unit on the north side, as normally that is the shaded side. This will enhance the operation of your 
unit. 

 

Use correct electric voltage and proper ampere for the unit to run effectively. 

 

Only let a certified electrician do any modifications to your electrical outlet or breaker. 

 

Use a dedicated line for the operation of your air conditioner to avoid the possibility of an electrical surge. 

 

If  the  supply  cord  is  damaged,  it  must  be  replaced  by  the  manufacturer  or  its  service  agent  or  a  similarly 
qualified person in order to avoid a hazard. 

 

The  dimensions  of  the  space  necessary  for  correct  installation  of  the  appliance  including  the  minimum 
permissible distances to adjacent structures. 

 

The appliance shall be installed in accordance with national wiring regulations. 

 

Disconnect the power supply before cleaning and maintenance. 

 

If the appliance is not connected by plug

an all-pole disconnection device which has at least 3mm separation 

distance in all pole and a residual current device (RCD) with the rating of above 10mA shall be incorporated in 
the fixed wiring according to the national rule. 

 

If the appliance is connected by plug

it must be positioned so that the plug is accessible. 

Содержание UVC09

Страница 1: ...R UVC12 ECOFER UVC18 ECOFER UVC24 Please read this user s manual carefully before operation and keep it for reference Ithomis Str 6 Chalandri GR 15231 Athens Greece el 30210 6715510 30211 7007269 3021...

Страница 2: ...Anti virus filter 7 DESCRIPTION OF COMPONENTS 8 View of unit 8 Display screen 8 Indicator light 9 Remote controller 10 Remote controller display 11 OPERATING METHOD 12 Emergency Run 12 How to Adjust A...

Страница 3: ...itioner at the place where there is flammable or corrosive air Operating instruction Please operate air conditioner in accordance to this manual Operating Instruction WARNINGS Following the safety mes...

Страница 4: ...and outlet of air conditioner It s normal 3 In heating operation strange smell may come from the unit It is Normal phenomenon 4 The performance parameters refer to name plate 5 The waterproof level of...

Страница 5: ...nd the drapes drawn on all the other window While cooking use an exhaust fan in the kitchen to remove the excess heat produced Only single phase a c power can be used please refer to nameplate for det...

Страница 6: ...d person in order to avoid a hazard Do not substitute fuse with lead wire or other materials Pull off power plug or switch off breaker if the air conditioner is not used for a long time Do not connect...

Страница 7: ...indicator will be on indoor and outdoor fan stop Heating overload protection When the temperature of indoor pipe is too high air conditioner enters heating overload protection And indoor fan speed sho...

Страница 8: ...dification operation louver blades can change the position automatically to prevent from dripping UVC TECHNOLOGY UVC working theory The UVC band has a short wavelength and high energy It destroys the...

Страница 9: ...upply air for 3 minutes to dry residual moisture Anti virus filter Lysozyme mainly breaks down the 1 4 glycosidic bond between N acetylmuramic acid and N acetylglucosamine in the cell wall so that the...

Страница 10: ...you selected Display screen RUN indicator This signal light is on when the unit is in RUNNING status When in Defrosting or Cooling airflow proof the indicator is flashing TIMER indicator This signal...

Страница 11: ...product is dispatched from factory 3 If there is any difference with the description mentioned above by your air conditioner please refer to next pages Indicator light PAUSE indicator This indicator...

Страница 12: ...air conditioner will adapt to HEAT COOL mode according to the D value between indoor temperature and set temperature 4 When AUTO mode is set Sleep function is not available 5 When DRY mode is set in...

Страница 13: ...mote controller and indoor unit Pressing two buttons simultaneously will result wrong operation Do not use wireless equipment such as mobile phone near indoor unit If interference occurs because of th...

Страница 14: ...d the Air conditioner will operate in AUTO mode Press Emergency Button again to switch off the unit How to Adjust Air Flow Horizontal direction If press the H SWEEP on the remote controller horizontal...

Страница 15: ...function b is optional and it is designed already before the product is dispatched from manufactory SERVICE AND MAINTENANCE Careful maintenance and overhaul in advance can prolong the air conditioner...

Страница 16: ...tergent Then dry it in the shadow 4 Insert air filter into the previous position and close the front panel Note 1 Air filter should be cleaned at least once every two weeks or heating or cooling capac...

Страница 17: ...hen it is cooling please use curtain or blind to obstruct direct sunlight Avoid Heat Sources When it is cooling using other heat sources may affect cooling effect Close Doors and Windows Incoming outd...

Страница 18: ...ople indoors 4 Check whether doors or windows are closed 5 Check whether fan speed or set temperature is improper Remote Controller is in Error The following trouble shooting is normal phenomenon Phen...

Страница 19: ...e gentle rustle sound when the unit starts or stops It is the normal sound of flowing refrigerant Walls carpet furniture or clothes indoors may disseminate peculiar smell In order to protect the unit...

Страница 20: ...ECOFER UVC09 UVC12 UVC18 UVC24 User manual 18...

Страница 21: ...ECOFER UVC09 UVC12 UVC18 UVC24 User manual 19 Ithomis Str 6 Chalandri GR 15231 Athens Greece el 30210 6715510 30211 7007269 30211 7007270 Fax 302106542877 Website www ecofer com gr...

Отзывы: