background image

ECOFER UVC09/UVC12/UVC18/UVC24                                User manual                                                                                                                                                                                   

 

 

 

 
 

SAFETY INSTRUCTIONS 

Symbol Description 

 

Warning

: A symbol indicating operation which may cause personnel casualties or serious damages. 

Caution: 

A symbol indicating operation which may cause personnel casualties or property damages. 

 

Installation Instruction 

  Warning:    Never install by yourself. 

Split  type  air  conditioner  will  work  for  you  for  a  long  period  of  time  if  it  is  correctly  installed.  Improper  installation 
could cause problems such as leakage of water or refrigerant, electric shock or fire. 

Caution

Please confirm the following before installation

 

Power  specifications: 

Make  sure  that  the  capacity of  socket or  breaker  and  power  cable  is  sufficient,  the  voltage  is 

correct and the socket or breaker is grounded. There may be hazard of fire or electric shock otherwise.

 

Proper connection of wires and piping: 

Improper connection may decrease the efficiency or cause air conditioner stop 

running. Water or refrigerant leakage may be resulted as well. 

Installation environments: 

Do not install air conditioner at the place where there is flammable or corrosive air. 

 

Operating instruction: 

Please operate air conditioner in accordance to this manual. 

 

Operating Instruction 

WARNINGS 

Following the safety messages is very important. These messages can save you from being injured or killed. Warning 
symbols alert you to be careful and means danger. Always follow instructions to be safe and reduce chances of injury 
or death. Warning and danger signs will precede safety messages. 
 

 

This appliance contains a UV -C lamp.   

 

Unintended  use  of  the  appliance  or  damage  to  the  housing  may  result  in  the  escape  of  dangerous  UV-C 
radiation. UV -C radiation may, even in small doses, cause harm to the eyes and skin. 

 

Read the user’s and installation instructions before opening the appliance.

 

 

Appliances  that  are  obviously  damaged  must  not  be  operated.  Prior  to  cleaning,  installation  or  other 
maintenance, the appliance must be disconnected from the supply mains. 

 

After  installation  or  maintenance  and  cleaning  do  not  switch  on  the  air  conditioner  without  installing  the 
panels. The indoor unit of the air conditioner must be fully assembled. 

 

UV-C lamps are for internal use inside the air conditioner only. Do not remove UV-C lamps for operating them 
outside of the appliance. 

 

Содержание UVC09

Страница 1: ...R UVC12 ECOFER UVC18 ECOFER UVC24 Please read this user s manual carefully before operation and keep it for reference Ithomis Str 6 Chalandri GR 15231 Athens Greece el 30210 6715510 30211 7007269 3021...

Страница 2: ...Anti virus filter 7 DESCRIPTION OF COMPONENTS 8 View of unit 8 Display screen 8 Indicator light 9 Remote controller 10 Remote controller display 11 OPERATING METHOD 12 Emergency Run 12 How to Adjust A...

Страница 3: ...itioner at the place where there is flammable or corrosive air Operating instruction Please operate air conditioner in accordance to this manual Operating Instruction WARNINGS Following the safety mes...

Страница 4: ...and outlet of air conditioner It s normal 3 In heating operation strange smell may come from the unit It is Normal phenomenon 4 The performance parameters refer to name plate 5 The waterproof level of...

Страница 5: ...nd the drapes drawn on all the other window While cooking use an exhaust fan in the kitchen to remove the excess heat produced Only single phase a c power can be used please refer to nameplate for det...

Страница 6: ...d person in order to avoid a hazard Do not substitute fuse with lead wire or other materials Pull off power plug or switch off breaker if the air conditioner is not used for a long time Do not connect...

Страница 7: ...indicator will be on indoor and outdoor fan stop Heating overload protection When the temperature of indoor pipe is too high air conditioner enters heating overload protection And indoor fan speed sho...

Страница 8: ...dification operation louver blades can change the position automatically to prevent from dripping UVC TECHNOLOGY UVC working theory The UVC band has a short wavelength and high energy It destroys the...

Страница 9: ...upply air for 3 minutes to dry residual moisture Anti virus filter Lysozyme mainly breaks down the 1 4 glycosidic bond between N acetylmuramic acid and N acetylglucosamine in the cell wall so that the...

Страница 10: ...you selected Display screen RUN indicator This signal light is on when the unit is in RUNNING status When in Defrosting or Cooling airflow proof the indicator is flashing TIMER indicator This signal...

Страница 11: ...product is dispatched from factory 3 If there is any difference with the description mentioned above by your air conditioner please refer to next pages Indicator light PAUSE indicator This indicator...

Страница 12: ...air conditioner will adapt to HEAT COOL mode according to the D value between indoor temperature and set temperature 4 When AUTO mode is set Sleep function is not available 5 When DRY mode is set in...

Страница 13: ...mote controller and indoor unit Pressing two buttons simultaneously will result wrong operation Do not use wireless equipment such as mobile phone near indoor unit If interference occurs because of th...

Страница 14: ...d the Air conditioner will operate in AUTO mode Press Emergency Button again to switch off the unit How to Adjust Air Flow Horizontal direction If press the H SWEEP on the remote controller horizontal...

Страница 15: ...function b is optional and it is designed already before the product is dispatched from manufactory SERVICE AND MAINTENANCE Careful maintenance and overhaul in advance can prolong the air conditioner...

Страница 16: ...tergent Then dry it in the shadow 4 Insert air filter into the previous position and close the front panel Note 1 Air filter should be cleaned at least once every two weeks or heating or cooling capac...

Страница 17: ...hen it is cooling please use curtain or blind to obstruct direct sunlight Avoid Heat Sources When it is cooling using other heat sources may affect cooling effect Close Doors and Windows Incoming outd...

Страница 18: ...ople indoors 4 Check whether doors or windows are closed 5 Check whether fan speed or set temperature is improper Remote Controller is in Error The following trouble shooting is normal phenomenon Phen...

Страница 19: ...e gentle rustle sound when the unit starts or stops It is the normal sound of flowing refrigerant Walls carpet furniture or clothes indoors may disseminate peculiar smell In order to protect the unit...

Страница 20: ...ECOFER UVC09 UVC12 UVC18 UVC24 User manual 18...

Страница 21: ...ECOFER UVC09 UVC12 UVC18 UVC24 User manual 19 Ithomis Str 6 Chalandri GR 15231 Athens Greece el 30210 6715510 30211 7007269 30211 7007270 Fax 302106542877 Website www ecofer com gr...

Отзывы: