Installation and user manual
- 16 -
before the water pump for long life circle.
➢
The user should start the water pump, and check for any leakage of water; Power on and press
the ON/OFF button of the heat pump, and set desired temperature in the
thermostat.
➢
In order to protect the heat pump, the heat pump is equipped with start delay
function. When starting the heat pump, the fan will start to run in 3 minutes, in another
30 seconds, the compressor will start to run.
➢
After pool heat pump starts up, check for any abnormal noise from the heat pump.
➢
Check the temperature setting
5.4. Maintenance and winterizing
5.4.1 Maintenance
The maintenance should be carried out once per year by qualified professional technician.
➢
Cut off power supply of the
heat pump before cleaning,
examination and repairing .
Do not touch the electronic
components until the LED
indication lights on PCB turn off.
➢
Please clean the evaporator with household detergents or clean water, NEVER use gasoline,
thinners or any similar fuel.
➢
Check bolts, cables and connections regularly.
5.4.2 Winterizing
In winter season when you don’t swim, please cut off power supply and drain water o
ut of the
heat pump. When using the heat pump under 2
℃
, make sure there is always water flow.
Important:
Unscrew the water union of inlet pipe to let the water
flow out.
When the water in machine freezes in winter season,
the titanium heat exchanger may be damaged.
Содержание FAIRLAND TurboSilence INVERX IXCR110T
Страница 2: ......
Страница 22: ...Installation and user manual 19 APPENDIX 1 HEATING PRIORITY WIRING DIAGRAM OPTIONAL...
Страница 23: ...Installation and user manual 20 APPENDIX 2 HEATING PRIORITY WIRING DIAGRAM OPTIONAL...
Страница 24: ...Installation and user manual 21 APPENDIX 3 HEATING PRIORITY WIRING DIAGRAM OPTIONAL...