Содержание Comfort 17

Страница 1: ...R COMFORT ECOFER FINE Please read this user s manual carefully to ensure proper use maintenance and installation Ithomis Str 6 Chalandri GR 15231 Athens Greece Τel 30210 6715510 30211 7007269 30211 7007270 Fax 302106542877 Website www ecofer com gr ...

Страница 2: ...nction of control panel 5 Humidity Level Timer 2 digit display 5 Push Button Functions 6 Draining the collected water 7 Emptying the Drainage Tank 7 Continuous Water Drainage 8 Maintenance 9 Cleaning the Dehumidifier 9 Storing the Dehumidifier 10 Clearance 10 Troubleshooting 11 Recycling 12 Guarantee 12 ...

Страница 3: ...imilarly qualified persons in order to avoid a hazard 12 This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance...

Страница 4: ...ings When defrosting and cleaning the appliance do not use any tools other than those recommended by the manufacturing company The appliance must be placed in an area without any continuously sources of ignition for example open flames gas or electrical appliances in operation Do not puncture and do not burn This appliance contains Y g see rating label back of unit of R290 refrigerant gas R290 is ...

Страница 5: ...um level of comfort Lightweight compact design for easy transport the light and ergonomic design of the dehumidifier allows it to be moved to any room Adjustable humidity the humidity is adjusted to the desired level Start Stop timer Program of the unit s automatic start and shutdown Silent operation Low noise level that makes it suitable for every room High energy efficiency extremely low power c...

Страница 6: ...User manual 4 Name of parts 1 Front shell 2 Outlet 3 Handle 4 Control Panel 5 Filter box 6 Back shell 7 Tank 8 Wheels 9 Supply cord ...

Страница 7: ...git display 1 when the unit is plugged in it will indicate the room humidity level 2 when you set the humidity it will indicate the humidity that you have selected 3 when you program the time for the unit to turn on and off it will show the hours 4 When the environment humidity is lower than 35 it will show LO 5 When the environment humidity is higher than 95 it will show HI ...

Страница 8: ... will stop When environment humidity is equel to or higher than the selected humidity by 3 compressor will restart once 3 minute compressor protection time over When setting the humidity to CO the compressor will run continuously 4 press button can be timer setting Press the button to program the time when the unit turns on and turns off If you want to cancel the timer programming press the button...

Страница 9: ... the user that the water needs to be emptied from the drainage tank Emptying the Drainage Tank 1 Lightly press on the sides of the tank with both hands and pull the tank out gently 2 Discard the collected water NOTE 1 Do not remove the float from the water tank The water full sensor will no longer be able to detect the water level correctly without the float and water may leak from the water tank ...

Страница 10: ...ank firmly into place with both hands If the tank is not positioned properly the TANK FULL sensor will be activated and the dehumidifier will not operate Continuous Water Drainage The unit features a continuous drainage port Using a plastic pipe with an inner diameter of 10mm inserts into drain hole on intermediate plate reach out from side of water tank install it in place and arrange the drain p...

Страница 11: ... firstly and remove the air filter 2 Clean the air filter Run a vacuum cleaner lightly over the surface of the air filter to remove dirt If the air filter is exceptionally dirty wash it with warm water and a mild cleanser and dry thoroughly 3 Attach the air filter Insert the filter into the grill smoothly and place the inlet grill into right place ...

Страница 12: ...store it note the following steps 1 Empty any water left in the drainage tank 2 Fold up the power supply cord and put it in the water tank 3 Clean the air filter 4 Discard in a cool and dry place Clearance Maintain the minimum clearance around the dehumidifier when the unit is operating as shown in the left drawing ...

Страница 13: ...instructed under Cleaning the dehumidifier Is the intake duct or discharge duct obstructed Remove the obstruction from the discharge duct or intake duct No air is discharged Is the air filter clogged Clean the air filter as instructed under Cleaning the dehumidifier Operation is noisy Is the unit tilted or unsteady Move the unit to a stable sturdy location Is the air filter clogged Clean the air f...

Страница 14: ...ropriate connection or installation The warranty is invalidated if alterations or repairs are made by unauthorized people The warranty is also invalidated in the following cases If a product for domestic use is used in an industrial environment If the product is not working any more due to another device in your home If the product s serial number has been removed If the product has been opened fo...

Страница 15: ...User manual 13 Ithomis Str 6 Chalandri GR 15231 Athens Greece Τel 30210 6715510 30211 7007269 30211 7007270 Fax 302106542877 Website www ecofer com gr ...