53/61
ESI Outdoor Unit Installation Instruction
05.2018
Manufacturer reserves the right to change at any time for specifications or designs without notice and incurring obligations.
Display
EEPROM fault
1.Error definition:
Data cannot be correctly received from the EEPROM, a type of memory component,
remembers contents even though the power supply is turned off.
2.Possible causes:
Damaged main control board
Display
Low voltage alarm
1.Error definition:
Power supply voltage is less than175VAC.
2.Possible causes:
Abnormal power supply voltage.
Damaged main control board.
YES
Cycle power for the unit, can the system back to normal?
External interference (e.g.
electromagnetic)
Replace the main control board
NO
YES
The power supply voltage is less than 175VAC.
Contact agency supplying power
to verify that they are sending the
correct voltage.
Replace the main control board
NO