background image

Connection diagram

MIN/MAX adjustment

Min. light output adjustment:

Max. light output adjustment:

Switch the light on using the  dimmer shaft. Then turn the dimmer to the 
left as far as possible (minimum light output). Are the bulbs blinking? Then 
turn the MIN pot meter slowly to the right with a screwdriver for stable light. 
Has the light become stable already? Then turn the MIN slowly to the left for 
an even better dimmability, to just before the point where the bulbs start 
blinking. This is the best dimmability for these LED bulbs.

Switch the light on using the dimmer shaft. Then turn the dimmer to the 

right as far as possible (maximum light output). Are the bulbs blinking?  Then 

turn the MAX pot meter slowly to the left with a screwdriver for stable light 

in the maximum light position. Has the light become stable already?   Then 

turn the MAX to the right for the maximum light output of these LED bulbs.

Use the MIN/MAX meter to set the minimum and maximum light output and

light stability.

Caution:

-  The installation of the dimmer on a 230 V supply must be done by a qualified  

  professional, taking the national regulations into account.  Make sure that the  

  electricity is switched off during all activities.

-  Do not connect mixed loads to the dimmer. E.g. a mix of LED lamps with  

  halogen, incandescent or energy-saving lamps.

LED dimmer phase control (R,L) and  

phase cut-off (R,C)

ECO-DIM.03

(Switch wire, often black)

(Phase wire, often brown)

Multi-way switching: