background image

4

ABOUT THE CONTROLS ON THE DEHUMIDIFIER

NOTE: When the tank is full or removed, the
controls cannot be set.

ON/OFF

Press to turn the dehumidifier on and off.

FILTER

Filter indicator reminds you to check and 
clean your filter.Remove the filter and clean it.
Press to turn off the Clean the Filter light. See
the Care and Cleaning section.

Humidity Set Control

The humidity level can be set within a range
of 80% to 35% RH (Relative Humidity) at
intervals of 5%.

In the LAUNDRY mode (CO)

For Laundry or continuous running, select the 
LAUNDRY mode (CO), the dehumidifier will

dehumidification settings if attached to a hose 
to drain or until the tank is full.
To set a lower desired humidity setting, press
press the - button and set to a lower percentage

To set a higher desired humidity setting,  press 
the + button and set to a higher percentage 
value (%).

Display

This is an active humidistat and can adjusted to 
your required levels (by using +/- button). 

FAN SPEED

Controls the fan speed.
Press to select High or Low fan
speed.
Set the fan control to High for maximum
moisture removal. When the humidity
has been reduced and quiet operation is
preferred, set the fan control to Low.

Select a choice of 2 hour or 4 hour timer.

TIMER

TANK  FULL Light

Glows when the tank is ready to be emptied,
or when the tank is removed or not replaced
in the proper position.

Alarm

If the tank is full or missing for more than three
minutes, an alarm will sound for about 10 seconds
to remind you to empty and replace the tank.

Auto Shut Off

The Water Level Control Switch shuts off the
dehumidifier when the tank is full, or when

the tank is removed or not replaced in the
correct position.

Auto Defrost

When frost builds up on the evaporator coils,
the compressor will cycle off and the fan will
continue to run until the frost disappears.

Auto Restart

In the case of a power outage or interruption,
the unit will automatically restart, in the settings
last used, after the power is restored.

Other Features

operate continuously at its maximum

value (%).

the humidity control to 45% or 50%. 
at least 24 hours for the dehumidifier to
achieve the humidity level. If you still have
damper air than desired, set the humidity
level to a lower setting or select Continuous
for maximum dehumidification.

After the unit has stopped (Other than tank full),it
will not restart for approx. 3 minutes. This is to 
protect the unit and is not a fault. Operation will 

Wait 3 minutes before resuming operation

automatically restart after 3 minutes.

When you first use the dehumidifier

TIP

4H

2H

2

1

5

6

High and Low fan
indicator lights

Tank full light indicates
tank needs to be emptied 
or it is not in the proper place

Laundry or Continuous
indicator light

Power On
indicator light

Clean the Filter
indicator light

4

3

4 hour or 2 hour

indicator lights

delay on/off

Содержание ECO DC12

Страница 1: ...reventative care on your part can save you a great deal of time and money over the life of your dehumidifier You ll find many answers to common problems in our troubleshooting section Review the chart of Troubleshooting Tips before calling your service engineers keeping your home safe and clean ECOAIR TECHNICAL SUPPORT UK TEL 0845 388 0007 EMAIL technical ecoair org ...

Страница 2: ...appliance should not be installed in the bathroom 5 The appliance should be installed in accordance with national wiring regulations and must be positioned so that the plug is accessible invalidate the warranty 7 Before the first operation check if the float in the tank is at the correct position If the position is not correct correct this by hand 6 If the power cord is damaged it must be replaced...

Страница 3: ......

Страница 4: ......

Страница 5: ...t replaced in the proper position Alarm If the tank is full or missing for more than three minutes an alarm will sound for about 10 seconds to remind you to empty and replace the tank Auto Shut Off The Water Level Control Switch shuts off the dehumidifier when the tank is full or when the tank is removed or not replaced in the correct position Auto Defrost When frost builds up on the evaporator co...

Страница 6: ...nt enclosed storage area such as a closet unless there is adequate circulation of air in and out of the area Do not use outdoors This dehumidifier is intended for indoor residential applications only This dehumidifier should not be used for commercial or industrial applications Place the dehumidifier on a smooth level floor strong enough to support the unit with a full tank of water Allow at least...

Страница 7: ...he hose if using the water tank to collect water When the hose is connected water will be drained out through it onto floor instead of into the tank Do not remove the tank while the unit is in operation or it has just stopped Otherwise it may cause some water to drip from the draining pan 14mm inner diameter hose 1 Remove the continuous drain cap 1by turning it anti clockwise then remove the rubbe...

Страница 8: ...NOTE The tank must be in place and securely seated for the dehumidifier to operate Air Filter The air filter should be checked and cleaned at least every 2 weeks of operation or when the FILTER light turns on Caution Do not operate the dehumidifier without a filter because dirt will gather and cause malfunction NOTE Do not use a dishwasher to clean the filter Clean the Filter indicator light will ...

Страница 9: ... room temperatures will reduce the moisture removal rate Models are designed to be operated at temperatures above 5 C Area to be dehumidified The capacity of your dehumidifier may not be adequate is too large Dehumidifier runs too much Doors and windows are open Close all doors and windows to the outside Dehumidifier has been recently This is normal Frost will usually disappear turned on or room t...

Страница 10: ... 9 220 240V 50Hz đ 5đ 35 220W 10 5kg Take off the power cord and plug and wrap them well when you do not use the unit for a long period take following steps to store the unit in good condition Model Rated Voltage Rated Frequency Power Consumption Moisture Removal at 30 80 Operating Temperature Weight Tank Capacity 3 5L ECO DC12 12L DAY LONG TERM STORAGE SPECIFICATIONS ...

Страница 11: ... with attempts to service or alter the unit will render this WARRANTY VOID The actual product may differ slightly from illustration For further information please contact 0845 388 0007 This product has been manufactured to comply with the EC Directives 2006 95 EC and 2004 108 EC SERVICE AND WARRANTY TWO 2 YEAR LIMITED WARRANTY Save This Warranty Information ments Copyright Reserved WEE EC2601UR ke...

Страница 12: ...66129914992 ...

Отзывы: