INSTALLATION INSTRUCTIONS

Operation and Maintenance

Ensure trouble-free CO2 supply.

The gear box is lubricated with grease. Do not fill with oil.

Maximum admissible pressure for the drip return is 60 bar.
Leave at least 12.6” (320 mm) of space in front of the valve casing or behind the Pump for service work.

Safety Rules

The operating instructions must be read and adhered to before performing any work on the pump or 

complete assembled unit. No responsibility will be carried by us for damage to materials or persons 

caused by improper handling of our pumps.

A safety valve is to be installed so that the admissible operating pressure cannot be exceeded by more than 

10%.

The pump has a protective device which prevents a sudden outflow of the medium due to mechanical com-

ponent failure. A greater degree of security is attained by fitting a safety shut-off valve on the suction side to 

avoid such outflow.

Pump operation without a safety valve as well as any excess in temperature or speed limits automatically 

voids the warranty.

When the pump is in operation, the shaft end must be covered by shaft guard (21) and the driven shaft side 

and coupling by a protective cover.

Fit shaft guard (21) using shaft guard holder (21A) and screws (17).

Pressure in the discharge line and in the pump must be at zero before any maintenance work to the pump 

and unit takes place. Close off the suction line.

Take necessary precautions to ensure that the driving motor cannot get switched on accidently (by discon-

necting the fuses, for example).

Make sure that the pump and all parts on the pressure side of the unit are vented and refilled, with pressure at 

zero, before starting the pump.

The absorption and pumping of air or CO2 in gas form as well as cavitation must be avoided.

Cavitation and/or compression of gases lead to uncontrollable pressure-kicks which can ruin the 

pump and pump unit parts and also be dangerous for the operator or anyone standing nearby.

CLP124 Lubrication Information/

Torque Specification/Tool List

Item #

Part #

Description

Torque

24C

CP04810

Connecting Rod Assembly

141 in.-lbs. (16 Nm)

29

CP04820

Plunger Kit

29.5 ft.-lbs. (40 Nm)

46L

CP04823

Valveset

47.2 ft.-lbs. (64 Nm)

49A

CP13430

Hexagon Nut with Rim

59 ft.-lbs. (80 Nm)

Содержание CLP124

Страница 1: ...3 Specifications page 4 Exploded View page 5 Parts List page 5 Repair Instructions page 6 Pump Mounting Selection Guide page 6 Dimensions page 7 Warranty Information back page Triplex Ceramic Plunger Pump Operating Instructions Repair and Service Manual Model CO2 Circulation pump ...

Страница 2: ...ally voids the warranty When the pump is in operation the shaft end must be covered by shaft guard 21 and the driven shaft side and coupling by a protective cover Fit shaft guard 21 using shaft guard holder 21A and screws 17 Pressure in the discharge line and in the pump must be at zero before any maintenance work to the pump and unit takes place Close off the suction line Take necessary precautio...

Страница 3: ...3 Exploded View CLP124 ...

Страница 4: ... PSI 300 BAR Maximum Power Consumption 40 BHP 30 kW Minimum Power Consumption 4 BHP 3 kW Maximum Speed 1000 RPM Plunger Diameter 0 94 24 mm Stroke 1 57 40 mm Inlet Port 2 x 1 1 2 BSP Discharge Port 2 x 1 BSP Crankshaft Mounting Either Side Shaft Rotation Top of Pulley Towards Fluid End Weight 183 lbs 83 kg Crankshaft Diameter 1 38 35mm ...

Страница 5: ...uard 1 21A CP05377 Shaft Guard Holder 1 22 CP04814 Crankshaft Assembly 1 ITEM PART DESCRIPTION QTY 23 CP13243 Fitting Key 1 24 CP04810 Connecting Rod Assembly 3 25 CP04815 Crosshead w Plunger 3 26 CP04816 Crosshead Sleeve 3 27 CP04817 Clip Ring 3 28 CP04818 Crosshead Pin 3 28A CP04819 Needle Bush 6 29 CP04820 Plunger Kit 1 31 CP07624 Radial Shaft Seal 3 43 CP04821 Valve Casing 1 43A CP04822 Restri...

Страница 6: ...o the front or push the drive end back Disassemble the plunger set 29 Screw off gear cover 4 and bearing cover 14 Remove conrod screws 24 and push the front conrod parts as far as possible into the crosshead guide Cut the roller bearing cages open and remove the roller parts Turn the crankshaft lightly and carefully hit it out to one side using a rubber hammer Important Do not bend conrod shanks C...

Страница 7: ...7 CLP124 DIMENSIONS MM INCHES ...

Страница 8: ...he product as a component part 5 Changes or modifications made by the customer or third party 6 The operation of pumps and or accessories exceeding the specifications set forth in the Operations Manuals provided by ECO2 Blast Liability under this warranty is on all non wear parts and limited to the replacement or repair of those products returned freight prepaid to ECO2 Blast which are deemed to b...

Отзывы: