EKO INSTRUMENTS CO., LTD. 4-20mA Signal Converter MC-11 Instruction Manual V1 

Pg. 2 

2.  Important User Information 

 
Thank you for using EKO Products 
 

Make sure to read this instruction manual thoroughly and to understand the contents before starting to operate the 

instrument. Keep this manual at safe and handy place for whenever it is needed. 

For any questions, please contact us at one of the EKO offices given below:

 

 
 

2-1. Contact Information 

 

EKO INSTRUMENTS 

CO., LTD.

 

Asia, Oceania Region 

 

 

www.eko.co.jp 
[email protected] 

EKO INSTRUMENTS Co., Ltd. 
1-21-8 Hatagaya, Shibuya-ku 
Tokyo, 151-0072 Japan 

 

Tel:  +81 (3) 3469-6713 
Fax:  +81 (3) 3469-6719 

Europe, Middle East, Africa Region

 

www.eko-eu.com 
[email protected] 

EKO INSTRUMENTS Europe B.V.

 

Lulofsstraat 55, Unit 32, 
2521 AL, Den Haag, The Netherlands

 

 

Tel:  +31 (0)70 3050117 
Fax:  +31 (0)70 3840607 

North & South America Region

 

www.eko-usa.com 
[email protected] 

EKO INSTRUMENTS USA Inc. 
95 South Market Street, Suite 300 
San Jose, CA 95113 USA 

 

Tel:  +1 408-977-7751 
Fax:  +1 408-977-7741 

 

 

2-2. Warranty and Liability 

For warranty terms and conditions, contact EKO or your distributor for further details. 

EKO guarantees that the product delivered to customer has been verified, checked and tested to ensure that 

the product meets the appropriate specifications. The product warranty is valid only if the product has been 

installed and used according to the directives provided in this instruction manual. 

 

In case of any manufacturing defect, the product will be repaired or replaced under warranty. However, the 

warranty does not apply if: 

 

Ø

 

Any  modification  or  repair  was  done  by  any  person  or  organization  other  than  EKO  service 

personnel. 

Ø

 

The damage or defect is caused by not respecting the instructions of use as given on the product 

brochure or the instruction manual. 

Содержание MC-11

Страница 1: ...4 20mA Converter A Box Version Number 1 INSTRUCTION MANUAL Tel 11 3976 4003 3999 7737 vendas romiotto com br www romiotto com br...

Страница 2: ...mation 5 3 1 WARNING CAUTION 5 3 2 HIGH VOLTAGE WARNING 5 4 Introduction 6 4 1 Main Functions 6 4 2 Package Contents 7 5 Getting Started 8 5 1 Parts Name 8 5 2 Setup 9 5 3 Measurement 11 6 USB Control...

Страница 3: ...050117 Fax 31 0 70 3840607 North South America Region www eko usa com info eko usa com EKO INSTRUMENTS USA Inc 95 South Market Street Suite 300 San Jose CA 95113 USA Tel 1 408 977 7751 Fax 1 408 977 7...

Страница 4: ...lection points Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from ina...

Страница 5: ...formity with the following harmonized standards of other normative documents Harmonized standards EN 61326 1 2006 Class A Emission EN 61326 1 2006 Immunity Test was done in this condition which are si...

Страница 6: ...ON Attention to user pay attention to the instructions given on the instruction manual with this sign HIGH VOLTAGE WARNING High voltage is used pay special attention to instructions given on this inst...

Страница 7: ...verter With the optional USB controller and EKO Sense software Multiple languages the converter settings can be freely changed This tool will be needed in case the sensor sensitivity might need to be...

Страница 8: ...ge is noticed please contact EKO immediately Table 4 1 Package Contents S Optional Items Qty Remarks USB Controller 1 unit Connecting cable 1 pc 1m with clamps Software 1pc On USB memory stick Quick S...

Страница 9: ...minal Numbers Parts Name Terminal Numbers 1 Pyranometer Signal Input Terminal 1 2 Pyranometer Signal Input Terminal 2 3 Temperature sensor NTC 10k 3 4 Temperature sensor NTC 10k 4 5 4 20mA Output Powe...

Страница 10: ...ranometers the Red terminal is connected to the terminal 2 and the Blue terminal to the terminal 1 of the converter input The cable shield must be connected to the aluminium housing by using the coppe...

Страница 11: ...ruction Manual V1 Pg 10 Wiring with fuse protection Even tough the output terminals are protected against surge a fuse can be applied in addition Figure 5 3 Wiring Voltage output 0 2 1V Example for a...

Страница 12: ...sensitivity values 4 20 mA 0 1600 W m 2 Measure the voltage across the precision shunt resistor which is connected in series with the 4 20mA output cable To convert the V output signal into the measu...

Страница 13: ...troller is a digital PC communication interface and provides power to the 4 20mA converter 6 2 Installation Install the Windows software executable file provided on the EKO USB memory stick After inst...

Страница 14: ...ext paragraph It gives a number of standard functions to open save settings or make a report of the setting applied Change settings 1 Select Sensor type 2 Set sensitivity Sensor calibration written on...

Страница 15: ...ated with the solar sensor sensitivity The converter output is less than 4mA Check whether the and wirings are connected in reverse polarity NOTE During nighttime conditions a negative voltage can be...

Страница 16: ...Humidity Range 95RH no condensation Response Time 1sec 99 Output Non Linearity 0 1 0 100mV Zero Offset 5 V Output offset value when 0mV at input 500 Power Supply Voltage Conversion Error 0 05 When su...

Страница 17: ...ENTS CO LTD 4 20mA Signal Converter MC 11 Instruction Manual V1 Pg 16 8 3 Dimensions Unit mm Figure 8 1 Dimensions Figure 8 2 Box Dimensions Tel 11 3976 4003 3999 7737 vendas romiotto com br www romio...

Страница 18: ...EKO INSTRUMENTS CO LTD 4 20mA Signal Converter MC 11 Instruction Manual V1 Pg 17 Japan www eko co jp Europe www eko eu com USA www eko usa com...

Отзывы: