Afterwards the normal transmission program is continued and the valve
operating mechanisms generate a signal tone as soon as they receive the
first correct signal.
• Press the ‘PROG’ button until ‘Sond’ appears in the LCD.
• Use the scroller to select the special ‘SynC’ function.
• To confirm your selection, briefly press the ‘PROG’ button.
• The LCD then displays the security code and the heating control counts
down from ‘120’ in steps of 1 second. After these 120 seconds the heating
control returns to the normal operating mode.
9.7. Test mode (‘tESt’)
You can use this function to check whether all the valve operating
mechanisms receive the radio signal correctly. The addressed valve
operating mechanisms acknowledge correct reception with an acoustic
signal. Use the scroller to select the valve operating mechanisms to be
tested.
If the large display shows a ‘0’, then all the receivers are tested, otherwise,
only the valve operating mechanism assigned to the displayed number is
tested. The timer in the left corner of the display counts down to the time at
which the next test cycle is to be started.
•
Press the ‘PROG’ button until ‘Sond’ appears in the LCD.
•
Use the scroller to select the special ‘tESt’ function.
•
To confirm your selection, briefly press the ‘PROG’ button.
•
Use the scroller to select the valve operating mechanism/s to be tested.
•
Press the ‘PROG’ button to quit the test function.
h) Displaying the valve position (‘StEL’)
When you select this menu item the heating control’s LCD indicates
how far the valve is opened
as a percentage (only for valve operating mechanism 1).
•
Press the ‘PROG’ button until ‘Sond’ appears in the LCD.
•
Use the scroller to select the special ‘StEL’ function.
•
To confirm your selection, briefly press the ‘PROG’ button.
28