8
WARNING
Fixture must use two fixing devices, and make sure the fixing device have locked! And only
fully clockwise rotate 90 ° can lock the hang fixture! Do remember plus a safety rope, and
do not connect the safety rope to plastic handle. It should be connect to the hole on the base!
4.3 FIXTURE CONNECT
Attention! One product only can accept one input one output.
B200 DMX cable include 3 contact pins:
Pin 1, FOR GROUND; Pin 2 connected to the negative polarity signal; The pin
3connected to the positive polarity signal.
DMX512 cable must use the professional shielded twisted pair cable; standard
loudspeaker cable is not reliable to control the long-range data. 24AWG cable is
suitable for more than 300 meters long-distance signal transmission and must add\
DMX 512 signal amplifier.
Do not use two outputs to separate the connection, if separate a continuous connection
to branch, DMX512 splitter is necessary.
Attention! Do not overload the connection. One continuous connection can only
connect up to 32 devices.
If use the DMX512 splitter. At first connect DMX512 Splitter input terminal to
controller .And then connected from the splitter output terminal to next device.
Do as above guide to connect other device, and finally coupled with terminal insertion
5. ALTERNATING CURRENT POWER SUPPLY
5.1 VOLTAGE, POWER, FUSE SPECIFICATION
Input Voltage
Total Power
Frequency
110~240V
230W
50/60HZ
Fuse voltage
Electronic current
Specification
250V
6A
5
×
20
5.2 POWER PROTECT
The equipment must be operated by professionals; Make sure that the voltage of
power supply must be comply with the voltage identified on the lamp, and must have
an overload or leakage electrical protection.
ATTENTION!
Factory has equipped the standard 3 pin plug socket. Connect the power supply as