background image

 

 

 

 

 

 

 

 

 

   Chapter  II Page 1 

 

II.1 Storage precautions

 

 

PREVENTION OF CHEMICAL ATTACKS ON THE SYSTEM 

 

Do  not  use  for  storage  purposes,  or  expose  the  unit  to,  hydrogen  peroxide,  chloramine, 

chloramine-T,  N-chloroisocyanide,  chlorine  dioxide,  hypochlorite,  chlorine,  iodine, 

bromine,  bromide,  phenolic  disinfectants  or  any  other  chemical  element.  The  use  of 

unauthorized  chemical  elements,  or  the  abuse  of  authorized  ones,  will  invalidate  any 

warranty. 

 

TEMPERATURE:  Never  expose  the  membrane  during  its  storage  to  temperatures 

higher  than  50ºC  or  lower  than  0ºC.  Never  store  the  membrane  vessel  under  direct 

sunlight.    Freezing  temperatures  will  result  in  mechanical  damage  to  the  system  due  to 

the expansion of air on freezing. This will cause irreversible damage to the membrane. 

 

DRYING OUT:   Never allow the membrane to dry out. If the membrane dries out, up to 

30%  of  production  flow  will  be  lost.  It  would  cause  irreversible  damages  to  the 

membrane. The membrane must always be kept damp. 

 

BIOLOGICAL  DIRT:  Protect  the  membrane  from  biological  dirt.  Up  to  40%  of 

production  flow  will  be  lost  if  the  membrane  gets  dirty  with  biological  slime.  Some 

production, but not all, can be recovered by following a thorough cleaning. 

 

CHEMICAL  DIRT:  Protect  the  membrane  from  chemical  attacks  or  dirt.  Be  careful 

when using the system in ports that may be polluted with chemical products, oil or fuel.  

Chemical attacks are not covered by the warranty. 

 

STORAGE: The inside of the membrane, which is dark and damp, is an excellent place 

for  microorganisms  to  reproduce.  When  the  membrane  is  used,  tested  or  operated 

intermittently, it is exposed to microorganisms. Up to 50% of production flow can be lost 

if the membrane is not stored correctly. 

 

 

Содержание Water-pro Compact S-90 12V

Страница 1: ...OMPACT S 60 90 12 24V DC Version 150720 Referencia 45200012 Eco Sistems Watermakers S L Oficina C Horta n 22 Almac n C Gran V a Puig i Cadafalch n 233 08203 Sabadell Barcelona Spain Tel 34 93 710 89 5...

Страница 2: ...FEEDING ASSY S 60 12 24 V DC LOW PRESSURE FILTER SET FILTER WRENCH HOSE 1 2 BLUE HOSE CLEAR BRAID O20 TUBE 8X6 BLUE 8 HOSE CLAMP 12 22 2 HOSE CLAMP 16 27 CONNECTOR O8TUBE X 1 4 BSP PLASTIC 2 ADAPTER 1...

Страница 3: ...FEEDING ASSY S 90 12 24 V DC LOW PRESSURE FILTER SET FILTER WRENCH HOSE 1 2 BLUE HOSE CLEAR BRAID O20 TUBE 8X6 BLUE 8 HOSE CLAMP 12 22 2 HOSE CLAMP 16 27 CONNECTOR O8TUBE X 1 4 BSP PLASTIC 2 ADAPTER 1...

Страница 4: ...unit off I 8 Maintenance of the unit CHAPTER II Storage and Cleaning II 1 Storage precautions II 2 Shutting down for short periods of time II 3 Shutting down for long periods of time CHAPTER III Parts...

Страница 5: ...CHAPTER I INTALLATION OPERATION AND MAINTENANCE...

Страница 6: ...S 60 90 12 24 V DC 1 2 3 4 9 8 5 10 11 12 13 15 16 17 22 19 21 12 24 V DC O20 O20 O15 O15 O15 O8 18 14 7 6 23 ST OP LAVA DO FRESH FLUSH eco sistems STOP PRODUCCION PRODUCTION LAVADO FRESH FLUSH 20 O20...

Страница 7: ...ure pump with energy saving system 9 High Pressure Gauge 10 R O Membranes and vessels 11 OPTIONAL Three ways valve for the produced water 12 Produced Water Flow meter 13 Anti Cl carbon filter 14 Produ...

Страница 8: ...R Gas for water intake 18 Wash System Options Three way valve 22 for winter storage and valve 11 for a direct take of the produced fresh water WARNING It is very important to place the feeding assembl...

Страница 9: ...ow E in the high pressure pump 8 Outlet elbow S in the high pressure pump 8 and the brine outlet 15 The referred elbows marked as E and S are located in the back lower part of the high pressure pump 8...

Страница 10: ...SH and it is equipped with a blue LED light It starts the timed Fresh Water Flush cycle For a proper operation the system doesn t allow the change from the Production function to the Flush function wi...

Страница 11: ...OWER POWER PUMP PUMP ALARMS BACK SIDE ELECTROVALVE 12 24V DC ACCORDING THE POWER SUPPLY PRESSURE SWICH N C REGULATED 18 BAR CONNECTOR red RJ 45 ETHERNET S 60 C 25A 24 V DC 50A 12 V DC S 90 C 40A 24 V...

Страница 12: ...wires from the breaker with the corresponding power box terminals marked as power supply 20 as indicated in scheme of Chapter I Page 6 Connect the motor pump terminals 4 with the ones marked as Pump...

Страница 13: ...n while pressing the Stop button in the control panel Both green and red LEDS will flash a few times Each green flash is equivalent to 400 working hours and each red flash is equivalent to 25 working...

Страница 14: ...er box will cut the power supplied to the motor pump and the power box To restore the original system conditions proceed by turning off and on the unit If the maximum pressure is exceeded the red led...

Страница 15: ...utes some air bubbles will be observed in the panel control flow meter 12 Those bubbles come from the interior of the membrane and other system elements causing some irregularities in the first high p...

Страница 16: ...on the temperature and salinity of the water I 7 Turning the unit off Before turning off the unit the system must be cleaned to prevent a compaction of the membranes due to the biological fouling in...

Страница 17: ...the system is switched off I 8 Maintenance of the unit Regularly check the status of the Sea Strainer 3 and clean the mesh when needed Replace the 5 micron filter with a new cartridge at the beginnin...

Страница 18: ...CHAPTER II STORAGE AND CLEANING...

Страница 19: ...VERY IMPORTANT REMEMBER THAT FOR A LONGER LIFE OF YOUR MEMBRANE YOU MUST CLEAN THE SYSTEM WITH FRESH WATER AFTER EVERY USE...

Страница 20: ...membrane DRYING OUT Never allow the membrane to dry out If the membrane dries out up to 30 of production flow will be lost It would cause irreversible damages to the membrane The membrane must always...

Страница 21: ...me or prolonged shutdown means when the unit will not be used for three months or more In this case the unit must first be rinsed with chlorine free fresh water and after that stored with a chemical p...

Страница 22: ...e entire circuit will contain this protecting solution Do not forget to keep closed the seacock valve 1 as a security measure 5 When the unit is ready to be turned on once again the sea cock valve 1 m...

Страница 23: ...CHAPTER III PARTS LISTING AND EXPLODED VIEW OF THE ST 15 CERAMIC ECO SISTEMS PUMP...

Страница 24: ...25 mm 1 44008180 18 Ring shank 1 44008190 19 Shaft stopper 25mm 1 44008200 20 Distributor cylinder 2 44008210 21 Distributor cap 2 44008220 22 Distributor necking cap 2 44008240 24 Cylinder cap 2 440...

Страница 25: ...911240 52 O ring 12x2 4 43911340 53 O ring 13x2 1 43911540 54 O ring 15x2 2 43912235 55 O ring 21 95x1 78 6 43912350 56 O ring 23x2 5 2 43914050 57 O ring 40x2 5 2 43914550 58 O ring 45x2 5 4 43915750...

Страница 26: ...4 6 7 8 9 12 13 17 18 47 19 20 21 22 24 25 26 27 15 30 31 35 36 2 5 39 46 40 41 44 42 43 45 50 51 52 50 53 54 59 56 58 61 60 57 61 58 62 30 31 65 66 66 67 67 68 69 ECO SISTEMS PUMP ST 15 36 38 48 55 1...

Страница 27: ...CHAPTER IV FILTERS AND MEMBRANE REPLACEMENT...

Страница 28: ...mantle the high pressure connectors taking care not to loosen the fittings of the end caps 3 located on the vessels 1 Disconnect the fresh water outlet tube Separate the membranes set from the frame b...

Страница 29: ...rackets Reassemble the membranes set to the frame fixing it with its screws Reconnect the high pressure hoses making sure the fitting nuts are well tight Connect the fresh water outlet NOTE De locatio...

Страница 30: ...A INLET ENTRADA INLET ENTRADA INLET ENTRADA INLET SALIDA OUTLET ENTRADA INLET SALIDA OUTLET SALIDA OUTLET SALIDA OUTLET SALIDA OUTLET FLOW ENTRADA INLET SALIDA OUTLET SEAL 2 1 3 4 6 5 Chapter IV Page...

Отзывы: