4/
Inspect all rope and glass seals and replaced as necessary.
If the cooker has not been used for a prolonged period, in excess of 6 months, the chimney should
be swept prior to use to check for blockages and rubble and debris blocking the flue ways.
NOTE; All solid fuel appliances produce considerably more Carbon Monoxide in normal use than oil
or gas appliances. But the general ‘smell’ of the smoke or exhaust is much stronger (with perhaps
the exception of smokeless fuel) and more easily detected by a healthy person. Always use your
appliance with the doors shut and look for tell tale signs of excessive leakage. Smoke stains above
the fireplace, smoke emitting around the door when running, strong smell of soot upstairs etc.
There is no such thing as a gas tight chimney, but there has to be a negative pressure inside a
chimney for it to draw oxygen through the fire box. Check the seals at the joints annually and re-fire
cement as required, check especially the joint of the flue pipe to the chimney register plate. Hairline
cracks are OK, but lumps of cement missing are a bad joint. A proper proprietary joint should be
used here, as they are far superior to cement and rope seals.
Never block air vents internally and externally
The surface of the appliance is hot in normal use; guards should be used when young children or
infirm people are around.
Never modify or fit parts not recommended by the manufacturer to the appliance.
Never use this appliance in the same flue as another appliance.
Installation Instructions
When installing these appliances, all local regulations, including those referring to national &
European Standards need to be complied with.
This manual covers the ECO Range wood pellet cooker appliance.
The nominal space heating output is: 4kW
The above appliances must be installed by a HETAS registered installer and the installation
registered with the local council.
Failure to comply with the above renders
all guarantees and liabilities of the manufacturer
null and void.
The manufacturer will not guarantee or accept liability for any problem that arises unless, a
HETAS installation commissioning certificate has been completed and a valid receipt or proof
of purchase is presented from the approved supplier.
Содержание Range cooker