SOFTENER REPAIR PARTS

(Models EP 6130, EP 6225, EP 6245 & EP 6260)

KEY

NO.

PART

NO.

DESCRIPTION

1

7112971

Shroud, Models EP 6225 & EP 6245

(Incl. Key No. 2)

7246649

Shroud, Model EP 6260

2

7026196

Base, Models EP 6225 & EP 6245

3

7176292

Clamp Section (2 req.)

4

7088033

Clamp Retainer (2 req.)

5

7112963

O--ring Seal Kit

6

--

O--ring Seal, 2--7/8 in. x 3--1/4 in.

7

--

O--ring Seal, 13/16 in. x 1--1/16 in.

8

--

O--ring Seal, 2--3/4 in. x 3 in.

9

7077870

Top Distributor

10

7105047

Repl. Bottom Distributor

11

0502272

Resin, 53 lbs (1 cu ft)

12

7113058

Resin Tank, 8 in. dia x 40 in.,

Models EP 6130 & EP 6225

7247996

Resin Tank, 10 in. dia x 40 in.,

Model EP 6245

7113074

Resin Tank, 12 in. dia x 54 in.,

Model EP 6260

13

7180314

Bottom Cover,

Models EP 6130 & EP 6225

7189449

Bottom Cover,

Models EP 6245 & EP 6260

14

7180291

Faceplate Cover, Models EP 6130 &

EP 6225 (also order following decal)

7260554

Faceplate Cover, Models EP 6245 &

EP 6260 (also order following decal)

z

7302720

Decal, Faceplate,

Models EP 6130 & EP 6225

7302738

Decal, Faceplate,

Models EP 6245 & EP 6260

15

7303213

Repl. Electronic Control Board (PWA)

16

7275907

Transformer

17

7192785

Salt Cover, Model EP 6130

7180437

Salt Cover, Models EP 6225,

EP 6245 & EP 6260

KEY

NO.

PART

NO.

DESCRIPTION

18

7178626

Rim , Model EP 6130 only

19

7155115

Brinewell Cover

20

7082150

Wing Nut, 1/4 -- 20

21

7100819

Brinewell

22

7003847

O--ring

23

7148875

Screw

24

7161831

Repl. Brine Tank, Model EP 6130

7114800

Repl. Brine Tank, Models EP 6225,

EP 6245 & EP 6260

25

1103200

Hose Adaptor

26

9003500

Grommet

27

0900431

Hose Clamp

28

7248706

Ground Clamp Assembly

29

7310171

Brine Valve Assembly,

Model EP 6130

7310197

Brine Valve Assembly,

Model EP 6225

7310210

Brine Valve Assembly,

Models EP 6245 & EP 6260

30

7095470

Brine Tube,

Model EP 6130 & EP 6225

7221746

Brine Tube,

Models EP 6245 & EP 6260

31

7113008

Float, Stem & Guide Assembly,

Models EP 6130 & EP 6225

7221754

Float, Stem & Guide Assembly,

Models EP 6245 & EP 6260

32

7116713

Clip

33

7308881

Brine Valve Body

34

7142942

Clip

35

7131365

Screen

36

7113016

Tubing Assembly

z

7139999

Drain Tubing

z

not illustrated.

Содержание EP 6260

Страница 1: ...ESTIONS WHEN INSTALLING OPERATING AND MAINTAINING YOUR CONDITIONER OR WHEN SETTING THE TIMER CALL TOLL FREE 1 800 693 1138 or visit www ecopurewaterproducts com Printed on recycled paper Systems teste...

Страница 2: ...of the warranty This warranty gives you specific legal rights and you may have other rights which vary from state to state This water conditioner is manufactured by North Star Water Conditioning 1890...

Страница 3: ...hem TABLE OF CONTENTS PAGE NO WARRANTY SAFETY GUIDES 2 SPECIFICATIONS DIMENSIONS 4 BEFORE STARTING INSTALLATION 5 TYPICAL INSTALLATION ILLUSTRATION 6 INSTALLATION STEPS 7 9 PROGRAMMING THE ELECTRONIC...

Страница 4: ...3 13 9 Water Supply Maximum Hardness gpg 70 60 80 120 Water Supply Max Clear Water Iron ppm D 8 5 12 16 Max Flow Rate gpm to Drain During Regen eration 2 0 2 0 2 0 2 0 Water Pressure Limits min max p...

Страница 5: ...and outlet fittings included with the softener allow water flow equivalent to 1 nominal pipe To maintain full valve flow 1 pipes to and from the softener fittings are recommended You should maintain t...

Страница 6: ...gle or 3 valve bypass INLET valve OUTLET valve BYPASS valve D for soft water SERVICE Open the inlet and outlet valves Close the bypass valve D for hard water BYPASS Close the inlet and outlet valves O...

Страница 7: ...adaptor elbow into the grommet 3 MOVE THE SOFTENER ASSEMBLY CAB INET MODEL OR RESIN TANK TWO TANK MODEL INTO INSTALLATION POSITION Be sure the installation surface is level and smooth If needed place...

Страница 8: ...will not work if water cannot exit this hose during regen erations Tie or wire the hose in place at the drain point Water pressure will cause it to whip during the back wash and fast rinse cycles of...

Страница 9: ...valve stem outward to service pausing several times to allow the softener to pressurize slowly 2 3 VALVE BYPASS Fully close the bypass valve and open the outlet valve SLOWLY open the inlet valve pausi...

Страница 10: ...e Manual Initiated Electronic Diagnostics on page 20 D A beeper sounds while pressing buttons for timer programming One beep signals a change in the timer display Repeated beeps means the timer will n...

Страница 11: ...pply NOTE If your water supply contains iron increase the hardness setting to compensate for it as fol lows Add 5 to the hardness for each 1 ppm of iron SET REGENERATION STARTING TIME NOTE RECHARGE TI...

Страница 12: ...h into and through the water softener to sanitize it Any air remaining in the unit is purged to the drain 4 After the recharge has completed fully open a cold water faucet downstream from the softener...

Страница 13: ...water 25 gpg hard has a mineral content equal in size to 5 aspirin tablets Water hardness varies greatly across the country It generally contains from 3 to 100 gpg Hard water affects living in genera...

Страница 14: ...led ion exchanging It is much like a magnet attracting and holding metals Water without the hardness minerals soft water flows from the softener and to the house pipes After a period of time the resin...

Страница 15: ...UT resin tank brine valve salt storage tank salt not shown resin bed hard water IN soft water OUT brine valve salt storage tank hard water IN hard water bypass OUT brine valve drain nozzle venturi bri...

Страница 16: ...The following is the best way to check for a salt bridge Salt should be loose all the way to the bottom of the tank Take a broom handle or like tool and careful ly push it down into the salt working i...

Страница 17: ...d side up concave side down Cap O ring Seal Screen Support Screen Nozzle Venturi Gasket Flow Plug HVDC Nozzle Venturi Housing Screen IMPORTANT Be sure small holes in the gasket are cen tered directly...

Страница 18: ...eration touch the same but ton once more VACATION NOTE EcoPure Demand water softeners regenerate only while water is used and softening capacity must be re stored For this reason the softener will not...

Страница 19: ...the defect and check the water meter ERROR CODE DISPLAYED Err 01 Err 03 Err 04 Err 05 POSSIBLE DEFECT wiring harness or connection to switch position switch motor inop erative valve defect causing hig...

Страница 20: ...d check correct switch operation CORRECT SWITCH DISPLAYS VALVE CYCLE STATUS Valve in service fill brining backwash or fast rinse position P Valve rotating from one position to another C While in this...

Страница 21: ...shining a flashlight into the brinewell and observing a noticeable drop in the liquid level NOTE Be sure a salt bridge is not preventing water with salt contact If the softener does not draw brine no...

Страница 22: ...22 SOFTENER REPAIR PARTS Models EP 6130 EP 6225 EP 6245 EP 6260 3 4 10 11 12 15 16 17 18 19 20 21 22 23 24 25 13 14 26 27 29 31 32 33 34 35 36 30 Valve Assembly see pages 24 27 1 2 5 6 7 8 9 28...

Страница 23: ...02720 Decal Faceplate Models EP 6130 EP 6225 7302738 Decal Faceplate Models EP 6245 EP 6260 15 7303213 Repl Electronic Control Board PWA 16 7275907 Transformer 17 7192785 Salt Cover Model EP 6130 7180...

Страница 24: ...PARTS Models EP 6130 EP 6225 50 51 52 53 54 55 59 58 cross section view seal wear strip 56 57 60 61 62 63 64 66 65 67 68 69 70 71 72 74 73 75 76 77 78 79 80 83 84 82 81 85 86 87 88 89 90 91 96 97 95...

Страница 25: ...4 in x 3 8 in 2 req 70 7081201 Retainer 71 7082053 Valve Body 72 7129889 Spring 73 7092642 Plug Drain Seal KEY NO PART NO DESCRIPTION 74 Seal Nozzle Venturi 75 O ring Seal 3 8 in x 9 16 in 76 Rotor S...

Страница 26: ...EP 6260 100 101 102 103 104 105 106 108 109 110 111 112 113 114 115 116 117 118 119 120 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 122 cross secti...

Страница 27: ...req 123 7094898 Turbine Support 124 7101548 Turbine 125 7309811 Sensor Housing Wiring Harness Asm 126 7081201 Retainer Nozzle Venturi 127 Seal Nozzle Venturi KEY NO PART NO DESCRIPTION 128 7171145 Val...

Страница 28: ...SERIAL NUMBER DATE PURCHASED DATE PART FAILED PARTS RETURN TAG CUSTOMER S NAME STREET ADDRESS CITY STATE ZIP CODE CONDITIONER MODEL NUMBER SERIAL NUMBER DATE PURCHASED DATE PART FAILED PARTS RETURN T...

Отзывы: