background image

145919-00  -  04-2020

Saga Xpress - SX

200-300 l.

EN-FR

SAFETY INFORMATION

O&M INFORMATION

INSTALLATION MANUAL

TDS - TECHNICAL DATA SHEET

INFORMATIONS DE SÉCURITÉ

INFORMATIONS FDV

INSTRUCTIONS DE MONTAGE

FT - FICHE TECHNIQUE

Содержание Saga Xpress - SX 200 - 3 + 3 kW

Страница 1: ...00 04 2020 Saga Xpress SX 200 300 l EN FR SAFETY INFORMATION O M INFORMATION INSTALLATION MANUAL TDS TECHNICAL DATA SHEET INFORMATIONS DE S CURIT INFORMATIONS FDV INSTRUCTIONS DE MONTAGE FT FICHE TEC...

Страница 2: ...damage may result if the product is not installed or used in the intended manner Keep this manual and other relevant doc uments where they are accessible for fu ture reference The manufacturer assume...

Страница 3: ...if it has been damaged or dropped This water heater should be serviced only by qualified service personnel Contact nearest authorized service facility for examination repair or adjustment IF YOU SMEL...

Страница 4: ...is switched on Maintenance settings should only be carried out by persons over 18 years of age with sufficient understanding The water heater can make water hot enough to cause severe burns instantly...

Страница 5: ...eries is designed to supply homes with hot running water The product can be used with alternative energy sources 2 3 Compliance The product complies with standards for Low voltage LVD 2014 35 EU Elect...

Страница 6: ...stat 8 2 Heating element 9 1 Drain valve factory fitted 10 3 Feet factory fitted A D B C E 5 2 3 4 1 6 7 9 7 8 8 10 All dimensions in mm 3 3 1 Risks during installation and maintenance Electric shock...

Страница 7: ...e placed in a room with drain to avoid any material damage in case of leakage Liability for consequential damage will only apply if this is followed The product should be placed in a dry and permanent...

Страница 8: ...et outlet combination to the desired position Tighten compression fitting to the cylin der see 3 5 4 B CW and HW pipes of a suitable size and quality should be led to the inlet outlet combination and...

Страница 9: ...op valve with sensor This can prevent possible material damage 3 5 5 Fitting instructions 3 5 6 Installation recommendation CAUTION The product should be placed in a room with drain to avoid any mater...

Страница 10: ...wer sup ply must be disconnected and secured against activation while the work is in progress Component Torque 5 4 heating element 60 Nm 5 Thermostat screws 2 Nm 0 1 Screw on the element head 2 Nm 0 1...

Страница 11: ...diagram 4 5 4 5 kW RESE T R E S E T M 2 1 2 3 4 THERM O DISC 60 C 90 C 80 C 70 C 1 3 2 RESE T R E S E T M 2 1 2 3 4 THERM O DISC 60 C 90 C 80 C 70 C 1 2 L1 L2 RESE T R E S E T M 2 1 2 3 4 THERM O DISC...

Страница 12: ...um and leave open prevents vacuum D Remove the cover at the drain valve 2 by loosening the screw 5 F Connect a hose to the nozzle on the drain valve Place the other end of the hose out side in a drain...

Страница 13: ...junction boxes Be fore any electrical work is done the power sup ply must be disconnected and secured against activation while the work is in progress WARNING Increasing the water temperature in the...

Страница 14: ...nt Contact authorized installer No hot water Power supply interrupted Verify that the fuse is on the earth breaker has not tripped Thermostat s has cut out Press the RESET button on the safety thermos...

Страница 15: ...d for unauthorized repair or replacement TheProducthasonlybeenconnectedtoadomesticmains water supply in compliance with the European Drinking Water Directive EN 98 83 EC or latest version The water sh...

Страница 16: ...eur et ne peuvent pas tre reproduites ni distribu es sans le consentement crit pr alable du fabricant Sous r serve de modifications Manufactured by OSO Hotwater AS Industriveien 1 3300 Hokksund Norway...

Страница 17: ...Saga Xpress SX 200 300 l FR INFORMATIONS SUR LA S CURIT INFORMATIONS SUR LE FONCTIONNEMENT ET LA MAINTENANCE MANUEL D INSTALLATION TDS NOTICE TECHNIQUE 145919 00 04 2020...

Страница 18: ...est pas ins tall ou utilis de la mani re pr vue Conservez ce manuel et tous autres docu ments pertinents en un lieu facile d acc s pour toute future consultation Le fabricant assume le respect par l u...

Страница 19: ...er de r paration agr le plus proche pour tout examen toute r para tion ou tout r glage SI VOUS SENTEZ DE LA FUM E coupez imm diatement l alimentation lectrique du chauffe eau Si la fum e persiste apr...

Страница 20: ...entretien les r glages ne doivent tre effectu s que par des personnes de plus de 18 ans dot es d une compr hension suffisante Le chauffe eau peut rendre l eau suffisamment chaude pour causer des br l...

Страница 21: ...ation pr vue La s rie Saga est con ue pour fournir aux lo gements de l eau courante chaude Le produit peut tre utilis avec des sources d nergie al ternatives 2 3 Conformit Le produit est conforme aux...

Страница 22: ...install e en usine 10 3 Pieds install s en usine A D B C E 5 2 3 4 1 6 7 9 7 8 8 10 Toutes les dimensions sont en mm 3 3 1 Risques pendant l installation et l entre tien Risque de d charge lectrique...

Страница 23: ...e pourvue d un siphon de sol pour viter des d g ts en cas de fuite La responsabilit pour les dommages cons quents ne s appliquera que si cette consigne a t respect e Le produit doit tre plac en un lie...

Страница 24: ...ison entr e sortie jusqu la position voulue Serrez le raccord de compression sur le cylindre voir 3 5 4 B Des tuyaux EF et EC de taille et de qualit appropri es doivent tre achemin s vers la combinais...

Страница 25: ...t viter d ventuels dommages mat riels 3 5 5 Instructions de montage 3 5 6 Recommandation pour l installation PRUDENCE Le produit doit tre plac dans une pi ce pourvue d un siphon de sol pour viter des...

Страница 26: ...r des composants lectriques il faut d brancher l alimentation et la s curiser contre tout risquederemisesoustensionaucoursdel intervention Composant Couple l ment chauffant de 31 75 mm 5 4 po 60 N m 5...

Страница 27: ...ma 4 5 4 5 kW RESE T R E S E T M 2 1 2 3 4 THERM O DISC 60 C 90 C 80 C 70 C 1 3 2 RESE T R E S E T M 2 1 2 3 4 THERM O DISC 60 C 90 C 80 C 70 C 1 2 L1 L2 RESE T R E S E T M 2 1 2 3 4 THERM O DISC 60...

Страница 28: ...d eau chaude au maximum et laissez le ouvert pour cr er une entr e d air pendant la vidange de l eau D Retirez le couvercle de la vanne de vidange 2 en desserrant la vis 5 F Raccordez un tuyau la buse...

Страница 29: ...ension Avant toute intervention sur des composants lec triques il faut d brancher l alimentation et la s curiser contre tout risque de remise sous tension au cours de l intervention AVERTISSEMENT Plus...

Страница 30: ...le n est pas grill que le disjoncteur diff rentiel ne s est pas d clench Coupure par le thermostat Appuyez sur le bouton de r initialisation RESET du ou des thermostat s de s curit Consultez le mode d...

Страница 31: ...placement non autoris s Le produit n a t raccord qu un r seau d eau potable conforme la directive europ enne sur l eau destin e la consommation humaine EN 98 83 CE ou sa version la plus r cente L eau...

Страница 32: ...eur et ne peuvent pas tre reproduites ni distribu es sans le consentement crit pr alable du fabricant Sous r serve de modifications Manufactured by OSO Hotwater AS Industriveien 1 3300 Hokksund Norway...

Отзывы: