background image

TROUBLESHOOTING CHECKLIST (Caution: shut off power to pump)

PROBLEMS

PUMP DOES NOT RUN  

AND MAKES HUMMING 

SOUND 

 

 

 

 

PUMP RUNS BUT DOES  

NOT DELIVER WATER 

 

 

 

 

PUMP RUNS BUT ONLY 

DELIVERS A SMALL  

AMOUNT OF WATER 

 

 

 

 

FUSE BLOWS OR 

CIRCUIT BREAKER 

TRIPS WHEN 

PUMP STARTS 

 

 

 

 

MOTOR RUNS FOR A  

SHORT TIME, THEN 

STOPS

POSSIBLE CAUSES/SOLUTIONS

•  Line circuit breaker is off, or fuse is blown or loose 

•  Pump cord is not making contact in receptacle. 

•  If all of the above are OK, then the motor could be malfunctioning. 

 

 

•  Impeller or volute openings are fully or partially clogged. 

  Remove pump and clean. 

•  Pump is air-locked. Start and stop several times by plugging and  

 

  unplugging cord. Check for clogged vent hole in pump case.  

•  Inlet holes in pump base are clogged. Remove pump and clean the    

  openings. 

•  Vertical pumping distance is too high. Reduce distance or change the  

  discharge fittings of the pump. 

 

•  Pump is air-locked. Start and stop several times by plugging in and    

  unplugging cord.  

•  Vertical pumping distance is too high. Reduce distance or change the  

  discharge fitting of the pump. Remove pump and clean the strainer    

  and openings. 

•  Impeller or volute openings are fully or partially clogged. 

  Remove pump and clean. 

•  Pump impeller is partially clogged with tar or paint, causing motor to   

  run slow and overload. Remove pump and clean. 

 

 
•  Pump impeller is partially clogged causing motor to run slow and  

 

  overload. Remove pump and clean. 

•  Motor stator may be defective. 

 

•  Fuse size or circuit breaker may be too small. (Must be 15 amps). 

•  Impeller or volute opening are fully or partially clogged.

  Remove pump and clean .  

 

•  Inlet holes in pump base are clogged. Remove pump and clean the    

  openings. 

•  Pump impeller is partially clogged causing motor to run slow and  

 

  overload. Remove pump and clean. 

•  Motor stator may be defective. 

•  Impeller or volute openings are fully or partially clogged. 

  Remove pump and clean. Also clean the strainer if one is installed.

 

ELECTRICAL PRECAUTIONS

 

  Before servicing a pump, always shut off the main power breaker and  

 

  then unplug the pump. Make sure you are not standing in water and are 

wearing insulated protective sole shoes, under flooded conditions. Contact your local electric 

company or a qualified licensed electrician for disconnecting electrical service prior to pump 

removal

Содержание PUP60

Страница 1: ...Owner s Manual PUP60 Portable Utility Pump General Safety 2 Specifications 3 Installation 4 6 Troubleshooting 7 Warranty 8 TABLE OF CONTENTS...

Страница 2: ...injury Indicates a hazard which if not avoided will result in death or serious injury Indicates a hazard which if not avoided could result in death or serious injury Indicates a hazard which if not a...

Страница 3: ...FICATIONS PERFORMANCE Capacity Cord Solids Model HP Volt Ph Amps GPH at 0 Max Head Construction Impeller Length Pumped PUP60 1 2 115 1 6 5 900 134 Thermoplastic Thermoplastic 6 PERFORMANCE Total Lift...

Страница 4: ...n pump until power is unplugged Do not cut off ground pin or use an adapter fitting Do not use an extension cord The pump power cord should be connected to a separately fused grounded line with a mini...

Страница 5: ...om the water to the pump as short as possible Set the pump on a level and firm base Protect the unit against flooding and excess mois ture Also be sure the weight of the pump is sup ported Make sure t...

Страница 6: ...6 Repair parts are available in kit form only Parts shown without reference number are not available for repair Replace the pump if those parts fail Attach one end of the suction hose to an outside h...

Страница 7: ...rge fitting of the pump Remove pump and clean the strainer and openings Impeller or volute openings are fully or partially clogged Remove pump and clean Pump impeller is partially clogged with tar or...

Страница 8: ...nably possible No requests for service will be accepted if received more than 30 days after the warranty expires Warranty is not transferable and does not apply to products used in commercial rental a...

Отзывы: