background image

INSTALLATION

1. Preparing the Basin for Installation

•  Remove the basin cover by removing the basin cover  

  fasteners. Remove the package containing the inlet hub  

  (D), check valve (C) and cord grommet (B). 

•  Remove the pump power cord and float switch cord 

  (if necessary) from the inside of the basin, removing all  

  slack from the cord(s). Ensure the cord(s) are not tangled  

  around the pump or float switch. Verify the float switch is  

  able to move freely.

•  Feed the cord(s) through the cord grommet hole (4) on  

  the basin cover, place the cover on the basin ensuring the  

  discharge flange and the discharge piping are in the 

  correct orientation. 

•  Press each cord through the slit and into the hole on the  

  cord grommet (B), 2 hole cord grommet for pumps with a  

  float cord and a 1 hole grommet for 1 cord systems. Press  

  the grommet (B) into the grommet hole (4) to provide a 

  tight seal. 

•  Secure the basin cover onto the basin with the basin cover  

  fasteners removed in the first step. 

2. Preparing the installation location

•  Excavate a hole large enough to accommodate the    

  basin (A), backfill material (1) and inlet piping (2).

•  Add 4 – 6 in. of clean sub-base material or concrete    

  (3) to the bottom of the hole.

•  Assure that it is level, compacted, and smooth.

•  Place the basin (A) in the hole and ensure that it 

  is level.

3. Connecting the inlet piping

•  Connect the inlet piping (1) as required by code 

  using the 4 in. snap-in inlet hub (D). Hand-Tighten    

  the hose clamp.

•  Carefully backfill with naturally rounded gravel or  

 

  stone, larger than 3/8 in. and smaller than 3/4 in. 

  diameter,around the periphery of the basin (A).

4

For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561

Содержание ESE50WB1830

Страница 1: ...Owner s Manual Pre Plumbed Sewage Basin System Features 2 3 Installation 4 5 Safety Information 6 7 Warranty 8 TABLE OF CONTENTS RSE50WB1830 ESE50WB1830...

Страница 2: ...vy duty ABS slip fit flexible union check valve passes a full 2in solid Molded inlet hub comes with a stainless steel clamp for securing the inlet pipe Performance Gallon Per hour Float Switch Model 0...

Страница 3: ...r with automatic reset thermal overload protection Ball bearings for quiet operation Handles 2 solids Easily replaceable 20 foot power cord Mechanical shaft seal for long life Support 400 lbs Sewage P...

Страница 4: ...for pumps with a float cord and a 1 hole grommet for 1 cord systems Press the grommet B into the grommet hole 4 to provide a tight seal Secure the basin cover onto the basin with the basin cover fast...

Страница 5: ...ve C and connect this pipe to the appropriate sewer main pipe for discharge Hand tighten the fittings to ensure a watertight seal 5 Attaching the vent connection Install a 2 in PVC Schedule 40 threade...

Страница 6: ...t area until all power is turned off If shut off box is in basement call the electric company to shut off service to the house or call your local fire department for instructions Remove pump and repai...

Страница 7: ...be submerged WARNING Do not use extension cords They are a fire hazard and can reduce voltage sufficiently to prevent pumping and or damage the motor WARNING Do not handle or service the pump while i...

Страница 8: ...le No requests for service will be accepted if received more than 30 days after the warranty expires Warranty is not transferable and does not apply to products used in commercial rental applications...

Отзывы: