Eco Air ECO901SN Скачать руководство пользователя страница 3

BS PLUG WIRING

(For models up to 12000 Btu)

Wiring Instructions: Should it be necessary to change the plug please
note the wires in the mains lead are coloured in accordance with the
following code :

BLUE - NEUTRAL
BROWN  LIVE
GREEN AND YELLOW - EARTH

As the colours of the wires in the mains lead of this appliance may not 
correspond with the coloured markings identifying the terminals in your 
plug, proceed as follows:

The 

BLUE

 wire is the 

NEUTRAL

 and must be connected to the terminal 

which is marked with the letter 

N

 or coloured 

BLACK

.

The 

BROWN

 wire is the 

LIVE

 and must be connected to the terminal 

which is marked with the letter 

L

 or coloured 

RED.

The 

GREEN/YELLOW

 is the 

EARTH

 and must be connected to the 

terminal which is marked with the letter 

E

 or     or coloured 

GREEN

 OR 

GREEN/YELLOW

.

Always ensure that the cord grip is positioned and fastened correctly.

If a 

13A (BS 1363)

 fused plug is used it must be fitted with a 1

3A 

fuse. 

If in doubt consult a qualified electrician.

Wiring for a 13 Amp Plug (BS1363)

Please note. The Earth Terminal is marked with the letter 

E

 or      Earth 

Symbol.

BS Plug Wiring

Содержание ECO901SN

Страница 1: ...t of Troubleshooting Tips before calling your service engineer Read This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips Review the char...

Страница 2: ...ake back the old appliance for disposal when you replace with a new product C Old products contain valuable resources which should be recycled as scrap metal Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground water and find their way into the food chain When using this air conditioner in the European countries the follow informatio...

Страница 3: ...must be connected to the terminal which is marked with the letter N or coloured BLACK The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED The GREEN YELLOW is the EARTH and must be connected to the terminal which is marked with the letter E or or coloured GREEN OR GREEN YELLOW Always ensure that the cord grip is positioned and fastened ...

Страница 4: ...lems in the chart of troubleshooting tips If you review the chart of Troubleshooting Tips first you may not need to call for service Contact an authorised service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to en...

Страница 5: ... earthing may cause electric shock It may cause fire and electric shock It may cause fire It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire and electric shock It may cause fire and electric shock It may cause electric shock or fire This could damage your he...

Страница 6: ...es food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the unit for a long time If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified service techn...

Страница 7: ...riods of time 2 Due to the possibility of oxygen deficiency ventilate the room when used together with stoves or other heating devices 3 Do not use this air conditioner for non specified special purposes e g Preserving precision devices food pets plants and art objects Usage in such a manner could harm such property 1 Do not touch the metal parts of the unit when removing the filter Injuries can o...

Страница 8: ...cator This indicator illuminates when the air conditioner is in AUTO operation DEFROST Indicator For cooling heating model only This indicator illuminates when the air conditioner starts defrosting automatically or when the warm air control feature is activated in heating operation DIGITAL DISPLAY Displays the current setting temperature when the air conditioner is in operation OPERATION indicator...

Страница 9: ...he panel firmly to its original position CAUTION 1 3 2 Mode Cooling operation Heating operation Drying operation Temperature 1 If air conditioner is used outside of the above conditions certain safety protection features may come into operation and cause the unit to function abnormally 2 Room relative humidity less than 80 If the air conditioner operates in excess of this figure the surface of the...

Страница 10: ...ection Adjust the vertical air flow direction to the desired direction In subsequent operations the vertical air flow is automatically set in the direction to which you adjusted the louver by pressing the AIR DIRECTION button To set the horizontal air flow direction left right Adjust the vertical louver manually using the lever on the left or right side of the vertical louver arm Depending on mode...

Страница 11: ... normal operation CAUTION 7 AUTOMATIC OPERATION When you set the air conditioner in AUTO mode it will automatically select cooling heating cooling heating models only or fan only operation depending on what temperature you have selected and the room temperature The air conditioner will control room temperature automatically round the temperature point set by you If the AUTO mode is uncomfortable y...

Страница 12: ...ler A cloth dampened with cold water may be used on the indoor unit if it is very dirty The front panel of the indoor unit can be removed and cleaned with water Then wipe it with a dry cloth Do not use a chemically treated cloth or duster to clean the unit Do not use benzine thinner polishing powder or similar solvents for cleaning These may cause the plastic surface to crack or deform CAUTIONS No...

Страница 13: ...o idle the unit for a long time perform the following 1 Operate the fan for about half a day to dry the inside of the unit 2 Stop the air conditioner and disconnect power Remove the batteries from the remote controller 3 The outdoor unit requires periodic maintenance and cleaning Do not attempt to do this yourself Contact your dealer or servicer Check that the wiring is not broken off or disconnec...

Страница 14: ... relative humidity A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting 3 Low noise of the air conditioner You may hear a low hissing sound when the compressor is running or has just stopped running This sound is the sound of the refrigerant flowing or coming to a stop You can also hear a low squeak so...

Страница 15: ...temperature If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device 9 Auto restart function Power failure during operation will stop the unit completely For the unit without Auto restart feature when the power restores the OPERATION indicator on the indoor unit starts flashing To restart the operation push the ON OFF button on the rem...

Страница 16: ...hat plug is securely in wall receptacle Replace the fuse Replace the battery Wait or cancel timer setting Set temperature correctly For detailed method please refer to Using remote control section Clean the air filter Close the doors or windows Clear obstructions away first then restart the unit Wait Inappropriate temperature setting Air filter is blocked Doors or Windows are open Air inlet or out...

Страница 17: ...MEMO Date of installation Purchased from Dealer Name Date of purchase Model number Serial number ...

Страница 18: ...sing from a faulty installation is specifically excluded This unit must be operated under conditions as recommended at voltages indicated on the unit Any attempts made to service or modify the unit by unqualified technician will render this WARRANTY VOID The actual product may differ slightly from the illustration This warranty is in addition to and does not affect your statutory rights For furthe...

Отзывы: