Warranty and Disclaimers 

 

 

WARRANTY 

 

The products described in this manual, with the exception of the O

2

 sensor, are warranted to 

be free from defects in material and workmanship for a period of one year from the date of 

shipment to the buyer.  Within the one year warranty period, we shall at our option replace 

such items or reimburse the customer the original price of such items which are returned to us 

with shipping charges prepaid and which are determined by us to be defective.  This warranty 

does not  apply  to  any item  which has been subjected to  misuse, negligence or accident; or 

misapplied; or modified; or improperly installed. 
 

The O

2

 sensor is considered an expendable part and as such cannot be covered by a warranty. 

 

This  warranty  comprises  the  sole  and  entire  warranty  pertaining  to  the  items  provided 

hereunder.    Seller  makes  no  other  warranty,  guarantee,  or  representation  of  any  kind 

whatsoever.  All other warranties, including but not limited to merchantability and fitness for 

purpose, whether express, implied, or arising by operation of law, trade usage, or course of 

dealing are hereby disclaimed. 
 
The warranty is void if the control module is opened or the wiring harness is modified. 

 

 

LIMITATION OF REMEDY 

 

Seller’s  liability  arising  from  or  in  any  way  connected  with  the  items  sold  and/or  services 

provided shall be limited exclusively to repair or replacement of the items sold or refund of 

the purchase price paid by buyer, at seller's sole option.  In no event shall seller be liable for 

any incidental, consequential or special damages of any kind or nature whatsoever, including 

but  not  limited to  lost profits arising  from  or in any way connected with items sold and/or 

services  provided  to  buyer,  whether  alleged  to  arise  from  breach  of  contract,  express  or 

implied warranty, or in tort, including without limitation, negligence, failure to warn or strict 

liability.  In no event shall the company's liability to buyer arising out of or relating to the 

sale of any product  or service exceed the purchase price paid by buyer to the company for 

such product or service. 
 

 

PRODUCT CHANGES 

 

We reserve the right to discontinue a particular product or to make technical design changes 

at any time without notice. 
 

Содержание XCM114

Страница 1: ...XCM114 O2 Lambda AFR Module Instruction Manual 07 15 2014 P N XCM114 4...

Страница 2: ...this manual may be photocopied or reproduced in any form without prior written consent from ECM ENGINE CONTROL AND MONITORING Information and specifications subject to change without notice XCM114 is...

Страница 3: ...nment where an oxidizer and fuel exist because the sensor may ignite the mixture Important Operation Notes 1 Before installing the O2 sensor apply a small amount of non lead containing antiseize compo...

Страница 4: ...4 XCM114 Kit Contents Not pictured This instruction manual P N XCM114 4...

Страница 5: ...rom 12 to 48 from the exhaust valve s of the engine Mount the O2 sensor in a location where liquids ex condensed water will not collect on the sensor Lightly coating its threads with a non lead contai...

Страница 6: ...aged sensors 1 Hold the sensor in quiescent air for at least 20 minutes Measure Vout or Iout and determine the O2 in the air from Appendix A Denote this O2 as O2cal and the measured Vout or Iout as Vc...

Страница 7: ...le should be interpreted as 0 i e there are no O2 molecules in the mixture Negative values are given for use in calculating Lambda AFR using the table below where it indicates a rich mixture O2 vs Lam...

Страница 8: ...rrected Lambdameasured B x P 1 B x P Equation 3b where Lambdacorrected the Lambda corrected for exhaust pressure Lambdameasured the Lambda output by the AFM B 0 000627 for Lambda 1 0 rich B 0 000830 f...

Страница 9: ...nected internally Current output mode using internal Int power i e Current Transmitter Type 3 Current output mode using external Ext power i e Current Transmitter Type 4 1 RDAQ in 4 20mA systems is ty...

Страница 10: ...on each side of the module and slide the PCB out of the enclosure 3 The switches for mode and current output power source are located on the lower left of the board labeled S3 S4 Set the position of t...

Страница 11: ...ed to the left Do not change the blue potentiometer adjacent to it Type Switches On Vout Range Iout Range 1 2 6 0 5 to 2 5 V 5 to 9 mA 2 2 7 2 5 to 4 5 V 9 to 12 mA 3 2 8 3 5 to 5 5 V 11 to 15 mA 4 4...

Страница 12: ...r the integrated diagnostic system Failure Mode Judgment Condition Action After Failure Condition Heater Stop Code Heater Open Off 1 x1 Heater Shorted Off 1 x2 Under or over Vbat Vbat 11V or Vbat 28V...

Страница 13: ...press implied or arising by operation of law trade usage or course of dealing are hereby disclaimed The warranty is void if the control module is opened or the wiring harness is modified LIMITATION OF...

Страница 14: ...926 5 294 5 685 6 101 6 543 7 013 7 513 8 045 8 609 10 9 209 9 844 10 518 11 231 11 987 12 788 13 634 14 530 15 477 16 477 20 17 535 18 650 19 827 21 068 22 377 23 756 25 209 26 739 28 349 30 043 30 3...

Страница 15: ......

Страница 16: ...Los Altos CA 94023 0040 USA 408 734 3433 Fax 408 734 3432 www ecm co com...