background image

 

12 

Troubleshooting 

 
 
If the PWR (Green) LED on the side of the unit is on, all is okay. 
 
If the PWR (Green) LED on the side of the unit is flashing continuously, the unit is warming 
up.  The sensor requires approximately 30 seconds of warm-up time after the unit is turned 
on. 
 
If the ERR (Red) LED is flashing 1, 2, 4, 5, or 6 times per second (see table on page 6), the 
UEGO sensor is broken.  Of course, this will occur if the sensor is not connected. 
 
Sometimes one or more of these codes will occur within 1 minute of power-up.   This is okay 
as long as they do not remain active after 1 minute. 
 
If  the  ERR  (Red)  LED  is  flashing  3  times  per  second,  the  battery  voltage  is  either  too  low 
(less than 11 V) or too high (greater than 28 V).  If this occurs, immediately stop the engine 
and supply the correct battery voltage to the control module. 
 
If the CAL POT cannot be turned counterclockwise to where the CAL (Yellow) LED is off 
then the sensor is bad. 
 
If the F/A Monitor outputs erroneous values, one of three conditions exists: 
 

1.

 

The  unit  is  being  confused  by  noisy  power  or  operating  in  an  electrically  noisy 
environment.    In  some  situations,  a  timing  light  might  create  a  noise  problem.  
Keeping the control module and its wiring harness away from the engine's ignition 
wires will help avoid this source of electrical noise. 

 
2.

 

For  the  F/A1000  only,  the  ground  wire  on  the  wiring  harness  is  not  attached 
directly to the ground at the vehicle’s battery.  If you connect a single wire from 
the wiring harness ground to the vehicle’s battery, a large voltage drop will occur 
across that wire and cause the analog output ground at the BNC connector to be 
elevated  above  battery  ground.    And  since  battery  ground  is  often  the  engine’s 
data  acquisition  ground,  if  you  hook  the  analog  output  ground  at  the  BNC 
connector  to  the  ground  at  the  data  acquisition  system  then  you  will  cause  a 
current  loop  through  the  ground  of  the  data  acquisition  system  to  the  vehicle 
battery. 

 

3.

 

The  F/A  Monitor  must  be  returned  to  the  factory  for  repair.    There  are  no  user-
repairable  components  inside  the  control  module.    The  warranty  is  void  if  the 
control  module  is  opened  or  wiring  harness  is  modified.    Contact  ECM  before 
returning the F/A Monitor to the factory. 

Содержание F/A1000

Страница 1: ...F A1000 F A1500 Fuel Air Ratio Monitor Instruction Manual 02 06 Part Number 1001A 6...

Страница 2: ...al may be photocopied or reproduced in any form without prior written consent from ECM ENGINE CONTROL AND MONITORING Information and specifications subject to change without notice F A1000 and F A1500...

Страница 3: ...put 4 SMB Interface Serial Measurement Bus F A1500 Only 5 Simulated O2 Sensor EGO Output 7 Calibration 8 Fuel Type Compensation 8 Pressure Compensation 8 Specifications and Limits 10 Measurement Range...

Страница 4: ...ii Supplementary Information 15...

Страница 5: ...cquisition or engine control systems SMB Serial Measurement Bus Interface on F A1500 Simulated O2 sensor output 11 to 28 VDC operation2 F A Monitor Components List The following items are included wit...

Страница 6: ...cause permanent sensor damage 4 Do not put the UEGO sensor in a heavily sooting or oil burning engine 5 Use of the UEGO sensor with leaded fuels over time may reduce the sensitivity of the sensor 6 D...

Страница 7: ...eads Install the UEGO sensor by lightly coating its threads with a non lead containing antiseize compound and tighten it to 30 3 ft lbf 40 4 Nm Attach the sensor to the wiring harness and route the ha...

Страница 8: ...e sure that all condensed water is out of the tailpipe before the tailpipe probe is inserted into the exhaust Analog Output The F A Monitor has a 0V to 5V linearized output suitable for input into a d...

Страница 9: ...the two SMB connectors on the F A1500 Cable part number 1500A 16 connects the PC to the SMB PC port of any one of the F A1500 modules i e it does not have to be the module with address 0 and subsequen...

Страница 10: ...Byte 10 Dh 16 bit Ip Low Byte Eh N A F A1500 Status Code See table below Fh N A PWR Green LED ERR Red LED FLASH CODE STATUS CODE CONDITION ON OFF 0 Data valid Sensor OK OFF 1 1 Sensor not connected or...

Страница 11: ...n to 1V rich signal that switches at Lambda 1 0 This is the same switch point as the production O2 sensor The simulated O2 sensor output is available at the short black wire near the blue connector of...

Страница 12: ...o of 1 85 and an O C ratio of zero If a fuel of a different composition is used Equation 2 can be used to compensate i e correct the F A Monitor s output F Acorr m 16p 12 2 368 x m 2p 4 x F Ameas Equa...

Страница 13: ...measured B x P 1 B x P Equation 3b where Lambda corrected the Lambda corrected for exhaust pressure Lambda measured the Lambda output by the F A B 0 000627 for Lambda 1 0 rich B 0 000830 for Lambda 1...

Страница 14: ...size is identical to that of most O2 sensors used in production vehicles Output Specifications and Limits Analog Output 0V at 0 125 F A gasoline 5V at 0 055 F A gasoline F A 0 014 x Vout 0 125 Output...

Страница 15: ...erminal Assignments F A1500 Only Cable from PC to SMB PC Port on F A1500 Module 6ft P N 1500A 16 DB9 Female to PC Terminal Number DB9 Male to Module Terminal Number 2 Rx 1 3 Tx 2 5 Gnd 6 SMB PC Cable...

Страница 16: ...e unit is being confused by noisy power or operating in an electrically noisy environment In some situations a timing light might create a noise problem Keeping the control module and its wiring harne...

Страница 17: ...unning engine When installing the F A Monitor s cabling and sensor on a stopped engine it is best to think out your moves before you make them Route and cable tie all cables away from hot moving sharp...

Страница 18: ...express implied or arising by operation of law trade usage or course of dealing are hereby disclaimed The warranty is void if the control module is opened or the wiring harness is modified LIMITATION...

Страница 19: ...15...

Страница 20: ...16...

Страница 21: ...17...

Страница 22: ...18...

Страница 23: ...19 State Diagram for SMB Communication...

Страница 24: ...20...

Страница 25: ......

Страница 26: ...Los Altos CA 94023 0040 USA 408 734 3433 Fax 408 734 3432 www ecm co com...