ENGLISH
19
Important
•
Connecting the machine to a fixed water connection and installing the pressure regulator has to be
carried out by authorized service personnel.
•
In order to avoid a premature calcification of your machine, we recommend to install a water
softening system.
5 FIRST USE
5.1 First use
Read the instruction manual carefully prior to operating the machine.
Prior to starting the machine, check if:
•
The steam and hot water valves are closed.
•
The machine is switched off. (On/Off dial in position 0.)
Now you can start up your machine:
Switch the rotary dial to position 1, so that the boiler is filled. The boiler is filled as soon as the pump stops. Now
switch the rotary dial to position 2. This makes sure that the machine is filled with water only when heated up. Press
the P-buttons of each brew group to release water.
Caution!
The heating element can burn if the machine is heated up without being filled with water (rotary dial at position 2).
control lamp red = The water level is too low and the pump fills the boiler
control lamp green = The machine is switched on
5.2 Programming of the dosage
To program the doses, proceed as follows:
Choose a porta filter and fill it with the desired quantity of ground coffee for the button you would like to program
(e. g. filter 1 cup for porta filter 1 cup: 7g coffee, button no. 1). Place a cup under the porta filter.
Please note:
When the left control panel is programmed, all other control panels are automatically
programmed/overwritten synchronously. If you would like to program the control panels individually, it is mandatory
to start programming with the left control panel and then proceed to the next.
1
Press the P- button until the lamp above the button flashes.
control lamp red
control lamp green