background image

 

Warranty and Disclaimers 

 

 

WARRANTY 

 

The products described in this manual, with the exception of the UEGO sensor, are 

warranted to be free from defects in material and workmanship for a period of one year from 

the date of shipment to the buyer.  Within the one year warranty period, we shall at our 

option replace such items or reimburse the customer the original price of such items which 

are returned to us with shipping charges prepaid and which are determined by us to be 

defective.  This warranty does not apply to any item which has been subjected to misuse, 

negligence or accident; or misapplied; or modified; or improperly installed. 
 

The UEGO sensor is considered an expendable part and as such cannot be covered by a 

warranty. 
 

This warranty comprises the sole and entire warranty pertaining to the items provided 

hereunder.  Seller makes no other warranty, guarantee, or representation of any kind 

whatsoever.  All other warranties, including but not limited to merchantability and fitness for 

purpose, whether express, implied, or arising by operation of law, trade usage, or course of 

dealing are hereby disclaimed. 
 
The warranty is void if the control module is opened or the wiring harness is modified. 

 

 

LIMITATION OF REMEDY 

 

Seller’s liability arising from or in any way connected with the items sold and/or services 

provided shall be limited exclusively to repair or replacement of the items sold or refund of 

the purchase price paid by buyer, at seller's sole option.  In no event shall seller be liable for 

any incidental, consequential or special damages of any kind or nature whatsoever, including 

but not limited to lost profits arising from or in any way connected with items sold and/or 

services provided to buyer, whether alleged to arise from breach of contract, express or 

implied warranty, or in tort, including without limitation, negligence, failure to warn or strict 

liability.  In no event shall the company's liability to buyer arising out of or relating to the 

sale of any product or service exceed the purchase price paid by buyer to the company for 

such product or service. 
 

 

PRODUCT CHANGES 

 

We reserve the right to discontinue a particular product or to make technical design changes 

at any time without notice. 

 

 15 

Содержание afm1000

Страница 1: ...AFM1000 AFM1500 Air Fuel Ratio Combustion Monitor Extended Range 6 20 AFR Version Instruction Manual 02 06 Part Number 1000A 6b...

Страница 2: ...al may be photocopied or reproduced in any form without prior written consent from ECM ENGINE CONTROL AND MONITORING Information and specifications subject to change without notice AFM1000 and AFM1500...

Страница 3: ...Warm up 5 Analog Output 5 SMB Interface Serial Measurement Bus AFM1500 Only 6 Calibration 8 Fuel Type Compensation 9 Pressure Compensation 9 Specifications and Limits 11 Measurement Range and Accuracy...

Страница 4: ...Supplementary Information 17 ii...

Страница 5: ...libration in air 0 to 5 volt linearized output for use with data acquisition or engine control systems SMB Serial Measurement Bus Interface on AFM1500 11 to 28 VDC operation2 AFM1000 AFM1500 Component...

Страница 6: ...iring Harness 20 or 1002A 3a1 Wiring Harness 10 or 1002A 3b1 Wiring Harness 3 1002A 3c1 4 SMB PC Cable 6 AFM1500 1500A 16 5 SMB PWR Cable 1 AFM1500 1500A 17 6 Calibration Screwdriver 2400E 35 7 Sensor...

Страница 7: ...ause permanent sensor damage 4 Do not put the UEGO sensor in a heavily sooting or oil burning engine 5 Use of the UEGO sensor with leaded fuels over time may reduce the sensitivity of the sensor 6 Do...

Страница 8: ...sensor by lightly coating its threads with a non lead containing antiseize compound and tighten it to 30 3 ft lbf 40 4 Nm Attach the sensor to the wiring harness and route the harness to the control...

Страница 9: ...t of the tailpipe before the tailpipe probe is inserted into the exhaust Analog Output The AFM has a 0V to 5V linearized output suitable for input into a data acquisition or engine control system The...

Страница 10: ...tween the two SMB connectors on the AFM1500 Cable part number 1500A 16 connects the PC to the SMB PC port of any one of the AFM1500 modules i e it does not have to be the module with address 0 and sub...

Страница 11: ...High Byte 6 0 to 20 0 AFR High Byte 256 Low Byte 100 9h 16 bit AFR Low Byte Ah 16 bit FAR High Byte 0 050 to 0 167 FAR High Byte 256 Low Byte 10000 Bh 16 bit FAR Low Byte Ch 16 bit Ip High Byte 3277 t...

Страница 12: ...l identify the module as an ETAS LA3 to INCA software Calibration Calibration of the AFM and the UEGO sensor can be easily performed using air To bring the system into calibration put the sensor in ai...

Страница 13: ...the fuel of H C m and O C p composition AFRmeas is the AFR output by the AFM i e 6 0 to 20 0 AFR m 2p 4 Pressure Compensation All wide range exhaust sensors have a pressure sensitivity Errors occur wh...

Страница 14: ...d B x P 1 B x P Equation 3b where Lambda corrected the Lambda corrected for exhaust pressure Lambda measured the Lambda output by the AFM B 0 000627 for Lambda 1 0 rich B 0 000830 for Lambda 1 0 lean...

Страница 15: ...Thread Size M18X1 5mm Lightly coat with non lead containing antiseize compound Hex Size 22mm Tightening Torque 30 3 ft lbf 40 4 Nm The UEGO sensor s thread size is identical to that of most O2 sensors...

Страница 16: ...minal Assignments AFM1500 Only Cable from PC to SMB PC Port on AFM1500 Module 6ft P N 1500A 16 DB9 Female to PC Terminal Number DB9 Male to Module Terminal Number 2 Rx 1 3 Tx 2 5 Gnd 6 SMB PC Cable Te...

Страница 17: ...ng confused by noisy power or operating in an electrically noisy environment In some situations a timing light might create a noise problem Keeping the control module and its wiring harness away from...

Страница 18: ...a running engine When installing the AFM s cabling and sensor on a stopped engine it is best to think out your moves before you make them Route and cable tie all cables away from hot moving sharp high...

Страница 19: ...ress implied or arising by operation of law trade usage or course of dealing are hereby disclaimed The warranty is void if the control module is opened or the wiring harness is modified LIMITATION OF...

Страница 20: ...16...

Страница 21: ...17...

Страница 22: ...18...

Страница 23: ...19...

Страница 24: ...20...

Страница 25: ...State Diagram for SMB Communication 21...

Страница 26: ...22...

Страница 27: ......

Страница 28: ...Los Altos CA 94023 0040 USA 408 734 3433 Fax 408 734 3432 www ecm co com...

Отзывы: