COMMAND DESCRIPTION
RANGE
FORMULA
0h
Enter Command Mode
See Command Mode and Device
Identification Sections
1h 8
bit
λ
0.744 to 1.373
λ
= (Data Byte + 186)/250
2h 16
bit
λ
High Byte
0.412 to 1.373
λ
= (High Byte*256 + Low Byte)/1000
3h 16
bit
λ
Low Byte
4h
16 bit Ri High Byte
0 to 400
Ω
Ri = (High Byte*256 + Low Byte)/10
5h
16 bit Ri Low Byte
6h
16 bit %O
2
High Byte
0.0 to 5.55
%O
2
= (High Byte*256 + Low Byte)/100
7h
16 bit %O
2
Low Byte
8h
16 bit AFR High Byte
6.0 to 20.0
AFR = (High Byte*256 + Low Byte)/100
9h
16 bit AFR Low Byte
Ah
16 bit FAR High Byte
0.050 to 0.167
FAR = (High Byte*256 + Low Byte)/10000
Bh
16 bit FAR Low Byte
Ch
16 bit Ip High Byte
-3277 to 672
µ
A
Ip = (High Byte*256 + Low Byte)/10
Dh
16 bit Ip Low Byte
Eh
N/A
AFM1500 Status Code (See table below)
Fh N/A
PWR (Green) LED
ERR (Red) LED
FLASH CODE
STATUS CODE
CONDITION
ON
OFF
0
Data valid/Sensor OK
OFF 1 1
Sensor not connected
or heater open
OFF 2 2
Heater
short
OFF 3 3
Power supply voltage
out of range
OFF
4, 5, or 6
4, 5, or 6
Sensor damaged
Flashing
OFF
8
30 second warm-up
ON ON 9
EE
Fault
ON
ON
10
Command Mode
7
Содержание afm1000
Страница 4: ...Supplementary Information 17 ii...
Страница 20: ...16...
Страница 21: ...17...
Страница 22: ...18...
Страница 23: ...19...
Страница 24: ...20...
Страница 25: ...State Diagram for SMB Communication 21...
Страница 26: ...22...
Страница 27: ......
Страница 28: ...Los Altos CA 94023 0040 USA 408 734 3433 Fax 408 734 3432 www ecm co com...