background image

i

Conversion Factors

Metric to English

Metric to Metric

English to Metric

From

To

Multiply By

actual cubic meter/h (am³/h)

actual cubic foot/h (acfh)

35.31

normal cubic meter/h (Nm³/h)

standard cubic foot /h (scfh)

38.04

degrees Celsius (°C)

degrees Fahrenheit (°F)

(°C x 9/5) + 32

kilogram (kg)

pound (lb)

2.205

kilowatt (kW)

Btu/h

3415

meter (m)

foot (ft)

3.281

millibar (mbar)

inches water column ("w.c.)

0.402

millibar (mbar)

pounds/sq in (psi)

14.5 x 10

-3

millimeter (mm)

inch (in)

3.94 x 10

-2

MJ/Nm³ Btu/ft³ 

(standard)

26.86

From

To

Multiply By

kiloPascals (kPa)

millibar (mbar)

10

meter (m)

millimeter (mm)

1000

millibar (mbar)

kiloPascals (kPa)

0.1

millimeter (mm)

meter (m)

0.001

From

To

Multiply By

actual cubic foot/h (acfh)

actual cubic meter/h (am³/h)

2.832 x 10

-2

standard cubic foot /h (scfh)

normal cubic meter/h (Nm³/h)

2.629 x 10

-2

degrees Fahrenheit (°F)

degrees Celsius (°C)

(°F - 32) x 5/9

pound (lb)

kilogram (kg)

0.454

Btu/h

kilowatt (kW)

0.293 x 10

-3

foot (ft)

meter (m)

0.3048

inches water column ("w.c.)

millibar (mbar)

2.489

pounds/sq in (psi)

millibar (mbar)

68.95

inch (in)

millimeter (mm)

25.4

Btu/ft³ (standard)

MJ/Nm³

37.2 x 10

-3

 

Appendix

Содержание Exothermics Tubular 545

Страница 1: ...Exothermics Tubular Heat Recuperators 3 20 2015 Installation Guide 545...

Страница 2: ...ing of replacement parts and Eclipse will not be liable for any other injury loss damage or expenses whether direct or consequential including but not limited to loss of use income or damage to materi...

Страница 3: ...Customer name Address City State Zip code Phone Fax Equipment Performance Estimate No Product Information Startup Record Model number Serial number Start Up Date Exhaust Volume Pressure Drop w c Exha...

Страница 4: ...erator Training 5 Replacement Parts 5 Installation 6 Receipt of Heat Recuperator 6 Installation 6 Rigging 6 Thermal Expansion 7 Ductwork 7 Flange Details and Gaskets 8 Operation and Startup 8 Temperat...

Страница 5: ...efforts dust created by sanding sawing grinding cutting and other construction activities could release crystalline silica Crystalline silica is known to cause cancer and health risks from the exposu...

Страница 6: ...ial to reach elevated temperatures Personal protection must be considered when installing this unit Because the flange connections are considered HOT connections provisions for expansion are required...

Страница 7: ...xpansion for the system Also it is recommended that permanent marks be placed on the support structure so thermal expansion can be monitored as part of a regular maintenance inspection program After s...

Страница 8: ...nute Exceeding this rate may cause damage to the heat recuperator due to excessive thermal stress An approved high temperature limit control should be installed in the hot gas inlet airstream Control...

Страница 9: ...ezing dirt dust or foreign materials and normal wear for that application are specifically excluded from this warranty Performance Warranty Performance figures or requirements if any must be addressed...

Страница 10: ...er mm inch in 3 94 x 10 2 MJ Nm Btu ft standard 26 86 From To Multiply By kiloPascals kPa millibar mbar 10 meter m millimeter mm 1000 millibar mbar kiloPascals kPa 0 1 millimeter mm meter m 0 001 From...

Страница 11: ...Notes ii...

Страница 12: ......