SUBTASK AMM-35-20-13-041-411-002
(Refer to
A. Install single mask auto-deployment oxygen mask
(1) Carefully place the passenger mask
, along with its lanyard cord, into the single
mask oxygen container.
(2) Using a flat-blade screwdriver, install the passenger mask oxygen supply tube to the
valve by screwing the threaded mask tubing fitting
that is in the end of the supply
tubing.
(4) Install the container door.
(5) Center and secure the decorative panel to the mask container door.
4.
Job Close-Up
SUBTASK AMM-35-20-13-041-921-002
A. Do adjustment/test of passenger oxygen system. Refer to
Oxygen System - Adjustment/Test
, SUBTASK AMM-35-00-00-071-701-002 – Passenger
Oxygen System Test.
(1) Apply masking tape on container doors of masks that are not being tested.
(2) Remove masking tape from container doors when testing is completed.
B. Remove all tools, equipment and unwanted material from work area.
C. If all other maintenance is complete, return aircraft to service. Refer to
AMM-20-00-02-051-801 – Return To Service (After Maintenance).
Eclipse 550 Aircraft Maintenance Manual — 06-123838
Temporary Revision No. 35-1
EFFECTIVITY: ALL
35-20-13
Page 402-Inst
Dec 16/19
© 2019 Eclipse Aerospace, Inc.