1.

 

INTRODUCTION 

Venous disease can be defined as a disease that affects the evolving venous system and is very prone to 

chronicity. The embrittlement and damage of vein walls as well as the disability of vein valves results in a 
backward blood flow known as venous disease, that consists in varicose veins, deep venous thrombosis and 
chronic venous insufficiency. 

Varicose veins are thus an epiphenomenon  of the venous disease, known as vein dilation, elongation and 
twisting accompanied by valve insufficiency, becoming the most common peripheral vascular disease, with 
an incidence ranging from 15 to 30% of the population, depending on the region. 

At the beginning, dilated thin-walled blood vessels are the so-called varicose veins, telangiectasias or spider 
veins.  They  can  be  regarded  as  the  minimum  indication  of  the  venous  disease,  having  only  an  aesthetic 
impact  but  not  compromising  human  health.  They  are  most  commonly  found  on  the  outer thighs,  behind 
the knees, on the ankles and on the face.  

Spider  veins  can  develop in  isolation,  in  clusters,  linearly,  spider-like  or  as large  “maps”.  Their  diameters 
range from 0.1 to 1 mm, and they are located on the sub  papillary plexus, at a depth ranging from 0.08 
mm to 0.2 mm (80 to 200 microns).  Consequently, they could be classified as having a capillary, arteriolar 
and vein origin. They have different diameters, some are rather bright red and others rather bluish.  

Treating telangiectasias and varicose vein poses mostly a cosmetic problem and occupies and outstanding 
place  in  phlebology  and  in  modern  aesthetic  medicine.  The  principle  used  for  treating  telangiectasias  is 
thermo coagulation, also used in the treatment of rosacea, cuperosis and ruby points.  

SPIDER vascular thermo-coagulator is based on the generation of a radiofrequency pulse that produces the 
thermal coagulation of veins resulting in their immediate removal, with no side effects or formation of scar 
tissue on the epidermis. Using very tiny and disposable needles coated with an insulating material, which in 
no case will affect the surrounding tissues, the thermo-coagulator provides an accurate scope of operation, 
but  no  side  effects.  It  consists  in  a  main  radiofrequency  unit  that  generates  the  pulses,  a  needle  holder 
(pencil), and extremely thin and accurate insulated, disposable needles.  

The  thermo-generator  creates  a  high  frequency  pulse  (radiofrequency),  as  the  needle  drives  it  to  the 
desired  location  with  absolute  accuracy.  This  enables  a  precise  amount  of  energy  to  be  delivered  at  the 
exact  location,  producing  a  thermal  injury  that  translates  into  an  effective  thermo  coagulation.  The 
temperature  in  the  small  vessel  reaches  approximately  70  ºC,  which  will  enable  the  coagulation  of  the 
plasma proteins and the destruction of the parietal structure. 

The  pulses  generated  with  SPIDER  are  stable  both  in  terms  of  intensity  and  time,  providing  a  very  high 
accuracy in coagulation and avoiding tissue charring, which makes the procedure very efficient and, at the 
same time, completely avoids the risk of causing skin lesions. 

The pulse may be adjusted in terms of duration and power, according to the condition being treated. Just 
combining these two values the exact power can be obtained to remove the lesion, providing long-lasting, 
immediate results in rapid sessions that require no preliminary preparation.  

SPIDER may be used for the whole body, even on most sensitive areas such as the ankles, the knees, and 
the face; it can be applied on all types of skins; no bandages are required, no subsequent rest or recovery 
period,  and  no  side  effects  arise  after  its  application.  The  treatment  is  highly  tolerable,  with  a  mild 
discomfort  and  no  risk  of  hyper  or  hypo  pigmentation,  no  scars,  no  hematomas,  no  swelling,  burns  or 
necrosis. 

The  following  pages  will  provide  you  with  useful  information  on  how  to  use  the  device  appropriately.  We 
advise that you read carefully these instructions before using SPIDER, and that you keep them for future 
reference. 

Please remember that this product is to be used exclusively in accordance with its approved use. 

The device must be used exclusively under the permanent supervision of qualified personnel. 

The device is to be used only at authorized centers that meet all the regulations in force. 

Содержание SPIDER

Страница 1: ...INMANUUIN148 USER MANUAL CE100 ING ARG V 16 04 2018 SPIDER VASCULAR TERMOCOAGULATOR...

Страница 2: ...3200 Web www ecleris com E Mail info ecleris com Directora T cnica Farm Doris In s Rasi Sanchez MN 12 856 Autorizado por la ANMAT PM 1120 36 Condici n de venta Venta exclusiva a profesionales e instit...

Страница 3: ...System configuration 9 9 4 Body treatments 10 9 5 Face treatment 11 9 6 Customized programs 11 9 7 Placing the needle for vascular lesions treatments 12 10 TREATMENTS 13 10 1 General precautions 13 1...

Страница 4: ...insulating material which in no case will affect the surrounding tissues the thermo coagulator provides an accurate scope of operation but no side effects It consists in a main radiofrequency unit th...

Страница 5: ...nant women Do not apply this treatment to people with epilepsy or heart conditions Do not apply this treatment to people incapable of expressing or disclosing an abnormal feel children elderly people...

Страница 6: ...in needle that is pressed almost perpendicular to and very superficially on the skin where the small vessel requiring treatment is located and which sends a highly efficient and accurate regulated the...

Страница 7: ...age 100 240 V N of phases 1 single phase Frequency 50 60 Hz Protection level against ingress of water and particles IPX0 Pedal IPX1 Consumption 100VA Fuse 2 x T2AL250V Cooling system Air forced convec...

Страница 8: ...Read the related documentation Warning Alternate current Protect from water This side up Environmental transport conditions Fragile Manufacturers information Name Address Type of applied BF equipment...

Страница 9: ...provided in this section 8 1 Unpacking 1 Remove the machine from the box 2 Check whether damage has occurred as a result of transportation 3 Ensure that everything has been delivered 4 In case of mis...

Страница 10: ...department of your local distributor or the nearest ECLERIS office prior to its use 9 2 Operation This system must be used only for medical paramedical or health professionals This device was not des...

Страница 11: ...alarm that triggers once the time stated in this control is up Every time treatment is started i e pushing the pedal for the first time within the selected program the TIMER will start the countdown...

Страница 12: ...nal so decides During treatment the values can be changed in the preset programs but such changes will not be saved You can change the POWER PULSE duration and DELAY This last feature represents the t...

Страница 13: ...any of these options will display a new screen containing the following 3 parameters POWER PULSE duration and DELAY described above in the Body Treatment section the values of which have been preset a...

Страница 14: ...ation value 9 7 Placing the needle for vascular lesions treatments SPIDER can be used with 2 needle types the smallest diameter 0 003 0 075 mm needle is used for very small blood vessels and the large...

Страница 15: ...ve or can it be applied on objects or animals 10 3 Before starting treament Before starting any treatment please read carefully the instructions below Disinfect the area to be treated Place the needle...

Страница 16: ...ro edema and erythema may be observed on the treated areas They will go away within a couple of days as the treatment develops You should warn the patient so that he she is aware of it A regenerating...

Страница 17: ...tion an excess application on the treated area Such pigmentation is often temporary and normally subsides Given a lack of desired results the following must be checked That the varicose vein size is a...

Страница 18: ...cision and safe technology No need of previous preparation by the patient Fast and user friendly technology Immediate results Applicable all year round For all types of skin It can be applied in any p...

Страница 19: ...ot use detergents solvents or any other abrasive agent Do not send to the autoclave any part or component of this device that are not specifically marked as autoclavable Do no sterilize or immerse the...

Страница 20: ...ty you may encounter PROBLEM PROBABLE CAUSE ACTION The device does not turn on It is not connected to the electrical network Connect the power supply cable to the electrical network The power supply c...

Страница 21: ...vice during thunderstorms After the use of the device turn it off and disconnect the power cable SPIDER is grounded through a conductor of the power supply cable This essential grounding is provided f...

Страница 22: ...c waste Research the local rules and laws for proper disposal It is the user responsibility to deliver the system to the proper location for disposal or recycle of electrical and electronic device or...

Страница 23: ...acturer We recommend using the following procedure to speed up the repair service and replacement of products under warranty 1 Contact the technical service department of your local distributor or the...

Страница 24: ...voice ECLERIS shall not be liable for any damage caused to by SPIDER due to negligence incorrect use cleaning or storage Any repairs made by people not authorized by ECLERIS shall void this warranty T...

Страница 25: ...t of this manual shall be reproduced by any means photocopy microfilm or other methods without the previous written authorization by ECLERIS likewise no part shall be reproduced multiplied or publishe...

Отзывы: