5.3. Balanced analog audio inputs
MIMO4040DN has on its rear panel 8 analog signal inputs (IN 1 to 8), balanced and
supporting line or microphone levels. The selection of the input signal type and its
management is done from the EclerNet Manager application. Refer to the EclerNet
Manager Application manual for more information.
The signal input connectors are Euroblock type. The assignment of the connection is as
follows:
Live or direct signal > Te
Cold or inverted signal > Terminal -
Ground
>
Terminal
For UNbalanced connections, short-circuit the terminal - to earth.
5.4. Balanced analog audio outputs
The rear panel of the MIMO4040DN has 8 analog signal outputs (OUT 1 to 8) and 2
additional "MONITOR" monitoring outputs, balanced and with line level.
The signal output connectors are Euroblock type. The assignment of the connection is as
follows:
Live or direct signal
>
Te
Cold or inverted signal
>
Terminal -
Ground
>
Terminal
For UNbalanced connections, leave the terminal - unconnected.