background image

 

 

5.

 

INSTALLATION 

5.1. Location, assembly and ventilation 

MIMO4040DN  has  been  specially  designed  to  be  placed  in  19"  rack  structure, 
occupying one unit. 
 

 

It is very important that, as a heat generating element, MIMO4040DN is not completely 
enclosed  or  exposed  to  extreme  temperatures.  Fresh  air  should  be  allowed  to  pass 
through the ventilation holes in the chassis, leaving at least one free rack unit between 
each piece of equipment and those installed above and below it in the rack frame. 
 
If the installation consists of several amplifiers in the same rack or is carried out inside 
cabinets  closed  by  means  of  doors,  it  is  highly  recommendable  to  equip  them  with 
forced  upward  ventilation,  installing  fans  at  their  lower  and  upper  ends.  This  upward 
flow of ventilation will favor the dissipation of the heat generated in its interior. 

5.2. Mains connection and power on 

MIMO4040DN operates on alternating voltages from 90 to 264V and 47 to 63 Hz. This 
device  is  equipped  with  an  oversized  power  supply  capable  of  adapting  without  any 
type of adjustment to the mains voltage of any country in the world. 

On the rear panel, next to the IEC power connector, there is an on/off switch for the unit. 
On  the  front  panel  there  is  an  LED  indicator  that  illuminates  when  the  unit  is  in 
operation. 

Do not allow the network cable to run parallel to the shielded cables carrying the audio 
signal, as this may cause humming. 

 

 

Содержание MIMO4040DN

Страница 1: ...v 20190416 MIMO4040DN DIGITAL MATRIX Digital Matrix with Dante Interface USER MANUAL ...

Страница 2: ... analog audio inputs 8 5 4 Balanced analog audio outputs 8 5 5 Digital audio inputs and outputs over IP Dante 9 5 6 Programming and control Ethernet port 11 5 7 Control remote RS 232 port 11 5 8 Remote control GPI ports 12 5 9 Remote control GPO ports 13 6 OBSERVATIONS 13 7 1 Ground loops 13 7 2 Background noise 13 7 PACKAGE CONTENTS 14 8 FUNCTION LIST 14 9 FUNCTION DIAGRAM 15 10 BLOCKS DIAGRAM 16...

Страница 3: ...rked with symbol of may be of sufficient magnitude to constitute a risk of electric shock The external wiring connected to the terminals requires installation by an instructed person or the use of ready made leads or cords WARNING To prevent fire or shock hazard do not expose this equipment to rain or moisture WARNING An apparatus with Class I construction shall be connected to a mains socket outl...

Страница 4: ... any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 14 Disconnecting from mains switching off the POWER switch all the functions and light indicators of the amplifier will be stopped but fully disconnecting the device from mains is don...

Страница 5: ...wnload at www ecler com It has 8 analog audio inputs and 8 analog audio outputs 32 digital audio inputs Dante and 32 digital audio outputs Dante converting it into a native 40x40 matrix with real routing of any input to any output 4 1 Main features 8 balanced MIC LINE analog audio inputs 42VDC phantom power independent per input channel Euroblock connectors 8 balanced analog audio outputs Eurobloc...

Страница 6: ...ect Configuration memory management presets Events scheduled on a calendar basis Broad DSP processing configurable Exemples o Matrix router mixer from any input to any output analog and or digital Dante with adjustable crosspoint level independent mixes of different inputs for each output o Treatment of channels in mono or stereo mode o Level mute vumeters and phase adjustment in inputs and output...

Страница 7: ...eans of doors it is highly recommendable to equip them with forced upward ventilation installing fans at their lower and upper ends This upward flow of ventilation will favor the dissipation of the heat generated in its interior 5 2 Mains connection and power on MIMO4040DN operates on alternating voltages from 90 to 264V and 47 to 63 Hz This device is equipped with an oversized power supply capabl...

Страница 8: ... of the connection is as follows Live or direct signal Terminal Cold or inverted signal Terminal Ground Terminal For UNbalanced connections short circuit the terminal to earth 5 4 Balanced analog audio outputs The rear panel of the MIMO4040DN has 8 analog signal outputs OUT 1 to 8 and 2 additional MONITOR monitoring outputs balanced and with line level The signal output connectors are Euroblock ty...

Страница 9: ...nte labeled as primary PRIMARY and secondary SECONDARY MIMO4040DN can work with these ports in two possible modes Redundant Mode there are two simultaneous network connections each with its own IP address both different so that the information Ethernet packets Dante are transmitted via both connections Each port primary and secondary must be connected to a different physical Ethernet local network...

Страница 10: ... connects to a network with a 1 Gbps link the secondary port must also connect at 1 Gbps Switched mode in this mode only a single network connection is actually enabled and therefore only one IP address exists with the primary and secondary ports behaving as ports of a network switch integrated within MIMO4040DN to which devices forming part of the system s Dante network or Ethernet switches formi...

Страница 11: ...te control service using customisable graphical control panels MIMO4040DN can act as a server for these panels included in an EclerNet project and also be remotely controlled by UCP panel client devices WPNETTOUCH Android or iOS mobile devices Windows devices etc 5 7 Control remote RS 232 port The RS 232 port with DB9 connector built into the rear panel allows an external device to communicate wit...

Страница 12: ...eries from Ecler Activation deactivation of a MUTE or SOLO by means of a push button or contact closure Retrieval of a preset by means of a pushbutton or contact closure The GPI connectors are Euroblock type The assignment of the connection is as follows Positive 10 VDC Terminal Variable voltage 0 10 VDC Terminal Ground Terminal Some connection examples The connection cables can be up to 500 meter...

Страница 13: ...hassis must never be connected to each other This way we avoid the formation of ground loops 7 2 Background noise MIMO4040DN has been designed to obtain the lowest possible background noise Regardless of the electronic design the background noise will depend directly on the correct use and installation of the unit It is not the same for example to have the GAIN control of a channel at 2 and the VO...

Страница 14: ...6 Digital audio traffic light Dante DANTE 7 Start up indicator light POWER 8 IEC type connector for external AC power cable 9 Fuse holder 10 Unit Power On Switch 11 Euroblock DC voltage control terminals GPI 12 Euroblock relay output terminals GPO 13 Ports Dante primary and secondary RJ 45 connector 14 Ethernet control port RJ 45 connector 15 DB9 connector for remote control via TP NET protocol RS...

Страница 15: ...15 9 FUNCTION DIAGRAM ...

Страница 16: ...16 10 BLOCKS DIAGRAM ...

Страница 17: ... in 0 5dB steps Input impedance Balanced 4k Phantom power 42VDC 5mA max software switched Headphones 200mW 200 Frequency response 3dB 5Hz to 24kHz Flatness better than 0 1dB THD Noise 1kHz 0dBV input line 0 004 THD Noise 1kHz 40dBV input mic 0 008 Output Noise floor FFT 20Hz 20kHz better than 115dB Interchannel crosstalk 20Hz 20kHz better than 90dB 100dB typ Channel Leakage 20Hz 20kHz better than ...

Страница 18: ...l in 12 18 24 dB oct Linkwitz Riley in 12 24 dB oct Input noise gate x40 Bypass On Off Threshold from 80 dBV to 18 dBV Depth 0 dB to 80 dB Attack time from 0 1 ms to 500 ms Hold time from 10 ms to 3000 ms Release time from 10 ms to 1000 ms Input compressor limiter x40 Bypass On Off Threshold from 36 dBV to 18 dBV Knee hard soft Ratio inf 1 limiter Attack time from 0 1 ms to 500 ms Release time fro...

Страница 19: ...None Melody 1 Melody 2 Chime Volume from 12dB to 0dB Mechanical Dimensions 482 6 x 44 0 x 266 5mm 19 0 x 1 7 x 10 5 Weight 3 25kg 7 17 lb Power supply Mains 90 264VCA 47 63Hz Power consumption 30VA Miscellaneous Management Connectivity Ethernet Base Tx 10 100Mb 1GB Auto X Over CAT5e or better GPI 8 from 0 to 12VDC or TTL level GPO 8 3 poles isolated relay 1A 48VDC max Aux Power Supply for Remotes ...

Страница 20: ...e to production tolerances NEEC AUDIO BARCELONA S L reserves the right to make changes or improvements in design or manufacture that may affect these product specifications Motors 166 168 08038 Barcelona España 34 932238403 information ecler com www ecler com ...