9
“PAGE” key: when pressed and held down, it activates the voice message
transmission function to the selected destination zones. If a “ding-dong” or
“chime” melody has been programmed in the paging station, it is emitted
when the PAGE key is pressed, and it is advisable to wait until it is finished
before starting the voice message.
Note: all functions of the above keys are configured from the eMIMO1616 web
application.
6.3 LED INDICATORS
Two-colour LED indicators for zone selection keys (1 to 16). Possible states and
their meaning:
Unlit: free zone (not used by another paging station or priority module, if
any)
Lit in green: zone selected by the paging station to broadcast the next
message
Lit in red: zone not selected in the paging station, but hold by another paging
station or module with higher priority
Flashing in orange: zone selected by the paging station, but hold by another
paging station or module with higher priority
Lit in orange: the broadcast of a message has been interrupted by another
paging station or priority module, totally or partially, and this lit LED warns
the user that the message has not been fully broadcasted in that destination
zone (regardless of whether it has been broadcasted in other zones or not).
The LED status is reset by pressing the corresponding zone selection key, the
ALL key or the CLR key.
Temporarily flashing in green: indicates a zone not enabled for selection from
the paging station
Two-colour LED indicator on the PAGE key. Lights while holding down the PAGE
key to indicate that the paging station is in message send mode:
Lit in orange: when you start sending a message (pressing and holding the
PAGE key), it indicates that the chime melody is playing (as determined with
the web control application), then turns green when the chime has finished
playing. Thus, the speaker knows when the chime ends and can start its
message without the risk of being covered by the chime (*)
Lit in green: paging function activated, with voice message broadcasting to
selected destination zones
Lit in red: the page station is not operational (not activated from the
eMIMO1616 unit, not connected to the control bus, etc.)