background image

 

 

8.

 

Do not install near any heat sources such as radiators, heat registers, stoves, 
or other apparatus (including amplifiers) that produce heat. 

 

9.

 

Do not defeat the safety purpose of the polarized or grounding type plug. A 

polarized  plug  has  two  blades  with  one  wider  than  the  other.  A  grounding 
type plug has two blades and a third grounding prong. The wide blade or the 

third prong are provided for your safety. If the provided plug does not fit into 

your outlet, consult an electrician for replacement of the obsolete outlet. 

10.

 

Protect the power cord from being walked on or pinched particularly at the 
plugs,  convenience  receptacles,  and  at  the  point  where  they  exit  from  the 

apparatus. 

11.

 

Only use attachments/accessories specified by the manufacturer. 

12.

 

Unplug  the  apparatus  during  lightening  sorts  or  when  unused  for  long 

periods of time. 

13.

 

Refer  all  servicing  to  qualified  personnel.  Servicing  is  required  when  the 
apparatus has been damaged in any way, such as power supply cord or plug 

is damaged, liquid has been spilled or objects have fallen into the apparatus, 

the  apparatus  has  been  exposed  to  rain  or  moisture,  does  not  operate 
normally, or has been dropped.

 

14.

 

Disconnecting from mains: Switching off the POWER switch all the functions 

and light indicators of the amplifier will be stopped, but fully disconnecting 

the  device  from  mains  is  done  unplugging  the  power  cord  from  the  mains 
input socket. For this reason, it always shall remain readily operable. 

15.

 

Equipment  is  connected  to  a  socket-outlet  with  earthing  connection  by 

means of a power cord. 

16.

 

The marking information is located at the bottom of apparatus. 

17.

 

The  apparatus  shall  not  be  exposed  to  dripping  or  splashing  and  that  no 

objects filled with liquids, such as vases, shall be placed on apparatus. 

 

NOTE:

 This equipment has been tested and found to comply with the limits for a Class 

A  digital  device,  pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to 
provide  reasonable  protection  against  harmful  interference  when  the  equipment  is 
operated  in  a  commercial  environment.  This  equipment  generates,  uses,  and  can 
radiate radio frequency energy and, if not installed and used in accordance with the 
instruction  manual,  may  cause  harmful  interference  to  radio  communications. 
Operation of this equipment in a residential area is likely to cause harmful interference 
in which case the user will be required to correct the interference at his own expense.  

 

WARNING

:

 

This product must not be discarded, under any circumstance, as 

unsorted  urban  waste.  Take  to  the  nearest  electrical  and  electronic  waste 
treatment centre. 

 

NEEC  AUDIO  BARCELONA,  S.L. 

accepts  no  liability  for  any  damage  that  may  be 

caused  to  people,  animal  or  objects  due  to  failure  to  comply  with  the  warnings 
above. 

Содержание eHSA2-250

Страница 1: ...eHSA2 250 eHSA2 500 eHSA4 250 eHSA4 500 HIGH IMPEDANCE AMPLIFIERS Multichanel amplifiers USER MANUAL ...

Страница 2: ...ling 6 5 2 Mains connection 6 5 3 Input signal connections 6 5 4 High pass filter 7 5 5 Output connections 7 6 OPERATION AND USAGE 7 6 1 Start up 7 6 2 Input attenuators 7 6 3 Indicators 8 7 CLEANING 8 8 FUNCTION DIAGRAM 9 9 FUNCTION LIST 9 10 TECHNICAL CHARACTERISTICS 10 11 BLOCK DIAGRAM 11 11 1 eHSA2 250 11 11 2 eHSA2 500 12 11 3 eHSA4 250 13 11 4 eHSA4 500 14 ...

Страница 3: ...rked with symbol of may be of sufficient magnitude to constitute a risk of electric shock The external wiring connected to the terminals requires installation by an instructed person or the use of ready made leads or cords WARNING To prevent fire or shock hazard do not expose this equipment to rain or moisture WARNING An apparatus with Class I construction shall be connected to a mains socket outl...

Страница 4: ...ifier will be stopped but fully disconnecting the device from mains is done unplugging the power cord from the mains input socket For this reason it always shall remain readily operable 15 Equipment is connected to a socket outlet with earthing connection by means of a power cord 16 The marking information is located at the bottom of apparatus 17 The apparatus shall not be exposed to dripping or s...

Страница 5: ...rs at an affordable price The models covered by this manual are eHSA2 250 2 x 250W RMS 100V eHSA2 500 2 x 500W RMS 100V eHSA4 250 4 x 250W RMS 100V eHSA4 500 4 x 500W RMS 100V Equipped with balanced inputs on Euroblock connectors Outputs also feature Euroblock connectors It has an electronic limitation system to avoid signal saturation and a thermal protection and DC OUT protection as well as a pr...

Страница 6: ... could cause humming In order to protect the power amplifier from eventual power consumption overloads it is protected by a set of fuses Should a fuse blow it must be replaced immediately by one with identical rating If it blows again please contact our Technical Service Department NEVER REPLACE THE FUSE WITH ANOTHER ONE WITH A HIGHER VALUE CAUTION Fuse substitutions have to be performed by a qual...

Страница 7: ... most important when the distances to cover are long ones 6 OPERATION AND USAGE 6 1 Start up The red PROT LEDs light up when you turn on the POWER switch A moment later all voltages have been stabilized and the amplifier is operating PROT indicators turn off In a complete audio installation it is important to power on the equipment according to the following sequence sound sources microphones musi...

Страница 8: ...rs is just below the actual clipping This CLIP system takes into account possible variations in the supply voltage always giving a real indication CLIP indicators light up to the beat of low frequencies when working at high power levels it s normal as low frequencies are those with higher energy content You must take care that these indicators do not remain continuously lit SP Signal Presence indi...

Страница 9: ...V 115V selector 7 Channel outputs Euroblock connectors 100V 8 High pass filter switch 9 Channel input attenuators 10 Channel input Euroblock connectors 11 Channel stack Euroblock connectors NOTE Listed functions are for two channel models for models with more than two channels the number of these functions matches the number of amplifier channels ...

Страница 10: ...z 75Hz 75Hz 75Hz THD Noise 1kHz Full Power 0 05 0 05 0 05 0 05 S N N 20Hz 20kHz 80dB 80dB 80dB 80dB CMRR 55dB 55dB 55dB 55dB Channel crosstalk 1kHz 55dB 55dB 55dB 55dB Input Sensitivity Impedance 0dB 20kΩ 0dB 20kΩ 0dB 20kΩ 0dB 20kΩ Mains voltage See characteristics in the back of the unit Power consumption pink noise 1 8 power 125W 195W 210W 380W pink noise 1 3 power 270W 425W 450W 860W Idle 40W 4...

Страница 11: ...11 11 BLOCK DIAGRAM 11 1 eHSA2 250 ...

Страница 12: ...12 11 2 eHSA2 500 ...

Страница 13: ...13 11 3 eHSA4 250 ...

Страница 14: ...14 11 4 eHSA4 500 ...

Страница 15: ...to production tolerances NEEC AUDIO BARCELONA S L reserves the right to make changes or improvements in the design or manufacturing that may affect these product specifications Motors 166 168 08038 Barcelona Spain 34 932238403 information ecler es www ecler com ...