8.

 

Do not install near any heat sources such as radiators, heat registers, stoves, or 
other apparatus (including amplifiers) that produce heat. 

 

9.

 

Do  not  defeat  the  safety  purpose  of  the  polarized  or  grounding  type  plug.  A 
polarized plug has two blades with one wider than the other. A grounding type 
plug has two blades and a third grounding prong. The wide blade or the third 
prong  are  provided  for  your  safety.  If  the  provided  plug  does  not  fit  into  your 
outlet, consult an electrician for replacement of the obsolete outlet. 

10.

 

Protect the power cord from being walked on or pinched particularly at the plugs, 
convenience receptacles, and at the point where they exit from the apparatus. 

11.

 

Only use attachments/accessories specified by the manufacturer. 

12.

 

Unplug the apparatus during lightening sorts or when unused for long periods of 
time. 

13.

 

Refer  all  servicing  to  qualified  personnel.  Servicing  is  required  when  the 
apparatus has been damaged in any way, such as power supply cord or plug is 
damaged, liquid has been spilled or objects have fallen into the apparatus, the 
apparatus has been exposed to rain or moisture, does not operate normally, or 
has been dropped.

 

14.

 

Disconnecting from mains: Switching off the POWER switch all the functions and 
light indicators of the amplifier will be stopped, but fully disconnecting the device 
from mains is done unplugging the power cord from the mains input socket. For 
this reason, it always shall remain readily operable. 

15.

 

Equipment is connected to a socket-outlet with earthing connection by means of 
a power cord. 

16.

 

The marking information is located at the bottom of apparatus. 

17.

 

The apparatus shall not be exposed to dripping or splashing and that no objects 
filled with liquids, such as vases, shall be placed on apparatus. 
 

NOTE: 

This equipment has been tested and found to comply with the limits for a Class 

A  digital  device,  pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to 
provide  reasonable  protection  against  harmful  interference  when  the  equipment  is 
operated in a commercial environment. This equipment generates, uses, and can radiate 
radio frequency energy and, if not installed and used in accordance with the instruction 
manual,  may  cause  harmful  interference  to  radio  communications.  Operation  of  this 
equipment in a residential area is likely to cause harmful interference in which case the 
user will be required to correct the interference at his own expense.  

 

WARNING

:

 

This product must not be discarded, under any circumstance, as 

unsorted  urban  waste.  Take  to  the  nearest  electrical  and  electronic  waste 
treatment centre. 

NEEC AUDIO BARCELONA, S.L. 

accepts no liability for any damage that may be caused 

to people, animal or objects due to failure to comply with the warnings above. 

Содержание eGPA2-150

Страница 1: ...50 0300 0109 Serie eGPA2 4 8 150 2 300 EN eGPA SERIES LOW IMPEDANCE AMPLIFIERS Multichannel amplifiers USER MANUAL...

Страница 2: ...lacement mounting cooling 6 6 2 Mains connection 6 6 3 Input signal connections 7 6 4 Power saving mode 7 6 5 Limiter circuit 7 6 6 Output connections 8 7 OPERATION AND USAGE 8 7 1 Start up 8 7 2 Inpu...

Страница 3: ...ked with symbol of may be of sufficient magnitude to constitute a risk of electric shock The external wiring connected to the terminals requires installation by an instructed person or the use of read...

Страница 4: ...fier will be stopped but fully disconnecting the device from mains is done unplugging the power cord from the mains input socket For this reason it always shall remain readily operable 15 Equipment is...

Страница 5: ...4 eGPA8 150 and a last one with a power of 2 x 310W RMS 4 eGPA2 300 All models use very high performance technology auto standby and convection cooling with a height of 1 rack unit Equipped with balan...

Страница 6: ...igh temperatures CAUTION The built in convection cooling requires at least one free rack unit empty space both above and below each amplifier to ensure a correct air flow It is also advisable not to r...

Страница 7: ...automatic switching circuit calling the power saving mode low power consumption when it detects no audio signal from the unit s inputs during more than 90 seconds and automatically recovering normal o...

Страница 8: ...rs must be of good quality sufficient section and as short as possible This is most important when the distances to cover are long ones 7 OPERATION AND USAGE 7 1 Start up The red PROT LEDs 7 light up...

Страница 9: ...kes into account possible variations in the supply voltage always giving a real indication CLIP indicators light up to the beat of low frequencies when working at high power levels it s normal as low...

Страница 10: ...10 9 FUNCTION DIAGRAM...

Страница 11: ...ndby status indicator 8 TH thermal protection indicator 9 ON power indicator 10 AUTO STANDBY switch 11 Power switch 12 CH 1 input 1 Euroblock connector 13 CH 2 input 2 Euroblock connector 14 STEREO MO...

Страница 12: ...l crosstalk 1kHz 55dB 55dB Input Sensitivity Impedance 0dBV 20k 0dBV 20k Anticlip 2dBV input 1 THD 1 THD Mains Voltage 100 240VAC Power consumption pink noise 1 8 power 4 63W 110W Power consumption pi...

Страница 13: ...55dB Input Sensitivity Impedance 0dBV 20k 0dBV 20k Anticlip 2dBV input 1 THD 1 THD Mains Voltage 100 240VAC Power consumption pink noise 1 8 power 4 113W 130VA 226W 260VA Power consumption pink noise...

Страница 14: ...14 12 BLOCK DIAGRAM eGPA2 150...

Страница 15: ...15 eGPA4 150...

Страница 16: ...16...

Страница 17: ...17 eGPA8 150...

Страница 18: ...ht to make changes or improvements in the design or manufacturing that may affect these product specifications For technical queries contact your supplier distributor or complete the contact form on o...

Отзывы: