Ecler DPA600 Скачать руководство пользователя страница 8

 

 

 

CLIP/PROT indicators functioning as CLIP indicator. 

 

These illuminate when the signal given to the loudspeakers is 1.5dB before the real clip. This CLIP system 

takes into account the possible variations in the mains voltage always giving a real indication even if the electric 
mains varies. It is normal that working at high power levels, the CLIP indicators illuminate at the rhythm of the low 
frequencies which are the ones that passes major energetic contents. Make sure these indicators are not 
permanently illuminated. 
 
 

THERMAL protection indicator (3) 

 

Alerts of the tunnel cooling temperature when it has risen above 90 centigrade degrees. The amplifier will 

then start up automatically when the temperature descends to 75 centigrade degrees. 

The DPA power amplifiers feature separate thermal protection systems per channel. They operate 

independently, meaning that if one channel triggers its protection system, the other one can perfectly continue its 
normal operation. 
 

SP Signal Presence indicator (4) 
It points to the existence of signal at the amplifier input. These indicators light up when the input signal 

surpasses -40dB. 
 
 

5.

 

CLEANING

 

 
 

The front panel should not be cleaned with dissolvent or abrasive substances because silk-printing could be 

damaged. To clean it, use a soft cloth slightly wet with water and neutral liquid soap; dry it with a clean cloth. Be 
careful that water never gets into the amplifier through the holes of the front panel. 

Содержание DPA600

Страница 1: ...USER MANUAL MANUAL DE INSTRUCCIONES NOTICE D EMPLOI BEDIENUNGSANLEITUNG...

Страница 2: ......

Страница 3: ...06 3 6 Output connections 07 4 OPERATION AND USAGE 07 4 1 Start up 07 4 2 Input attenuators 07 4 3 Indicators 07 5 CLEANING 08 6 FUNCTION LIST 09 7 FUNCTION DIAGRAM 09 8 TECHNICAL CHARACTERISTICS 31 9...

Страница 4: ...be outlined as follows a Lower internal resistance than bipolar transistors which leads to less heating of the amplifier and more powerful and controlled bass Conventional Mosfets have a 4 to 7 times...

Страница 5: ...are Its exceptional audio processing features make it a particularly versatile tool Equalizer with 10 filters Crossover with variable filter slopes Delay Phase inversion Signal generator Remote level...

Страница 6: ...nerate excessive excursions of the woofer s diaphragm The DPAs feature a switchable Butterworth shaped Subsonic Filter located inside the unit see fig with a 25Hz cut off frequency and 18dB oct slope...

Страница 7: ...to start up the equipment in the following sequence sound sources mixer equalizers active filters and finally power amplifiers To turn them off the sequence should follow an inverse pattern 4 2 Input...

Страница 8: ...centigrade degrees The amplifier will then start up automatically when the temperature descends to 75 centigrade degrees The DPA power amplifiers feature separate thermal protection systems per channe...

Страница 9: ...indicator SP 5 Illuminated mains switch 6 Mains socket 7 Switch to disconnect chassis earth electrical Ground GND LINK 8 Earth terminal GND 9 Jack output connector to other amplifiers STK OUTPUT 10 In...

Страница 10: ...1 0 05 0 08 0 08 0 08 TIM 100 0 01 0 01 0 01 0 01 S N N 20Hz 20kHz 1W 4 85dB 85dB 85dB 85dB Damping factor 1kHz 8 300 300 300 300 Slew Rate 60V s 65V s 75V s 80V s Channel crosstalk 1kHz 75dB 75dB 75d...

Страница 11: ...32 9 DIAGRAMS 9 DIAGRAMAS 9 SCH MAS 9 DIAGRAMME 9 1 Figures 9 1 Figuras 9 1 Sch mas 9 1 Abbildungen...

Страница 12: ...33...

Страница 13: ...34 9 2 Block diagram 9 2 Diagrama de bloques 9 2 Diagramme de blocs 9 2 Blockschatbild...

Страница 14: ...35...

Страница 15: ...ECLER Laboratorio de electro ac stica S A Motors 166 168 08038 Barcelona Spain INTERNET http www ecler com e mail info ecler es 50 0093 01 04...

Отзывы: