9
Notes
:
1. If the device is in special mode for 10 seconds and the front knob is not touched, the
equipment automatically reverts to VOL/MUTE mode.
2. In tone control mode, when you turn the knob in either direction it flashes fast while the
gain of the affected tone increases. When either end of the scale is reached (-10 ó
+10dB) or when it goes through the centre point (0dB) it flashes more slowly.
4.3. AUTO STANDBY Function
The
AUTO STANDBY
function (idle or low consumption mode) means you can install the
CA40 in inaccessible places and leave the device connected to the mains power supply indefinitely
because when no signal is detected, it automatically goes into standby mode, saving energy.
To
enable
AUTO STANDBY
use the micro switch with the same name on the rear panel of
the unit (see section
7. DIAGRAM OF FUNCTIONS
). When activated, if there is no audio signal in
any of the inputs (or the signal is very weak, below the activation threshold), the CA40 automatically
goes into STANDBY mode, and the
ON/STBY
on the front panel of the device goes orange. When a
valid audio signal is detected in any of the inputs, the CA40 leaves standby mode and starts
operating normally again and the
ON/STBY
LED goes green.
When you enable
AUTO STANDBY
mode with the micro switch (position
ON
) one of two
things happens:
a) There is NO audio signal in the inputs. Result: the amplifier immediately goes into
AUTO STANDBY mode
b) There is an audio signal in the inputs. Result: the amplifier stays active
When the amplifier goes into
AUTO STANDBY
mode, all the LED indicators go out with
the exception of
ON/STBY
. If the amplifier is in STANDBY node and you turn the
VOL/MUTE
knob to adjust the volume or activate the MUTE function, the LED lights will come on for a short
time then go out again. Remember that the first acting on the VOL/MUTE knob, this will only reset
the LED indicators, and will not change any of the settings.
When the unit is a special mode (source selection or setting adjustment) the LED
indicators will not go out even if the amplifier is in
AUTO STANDBY
mode.
4.4. LED indicators
SP
: The signal presence or
SP
LED indicator shows that there is a signal in the
amplifier input. This lights up when the input level reaches the established
detection threshold.
CLIP
: The saturation or
CLlP
LED indicator comes on when the signal delivered to
the speakers is close to the amplifier's clipping or saturation level. Input signals
should be set to ensure the
CLIP
(saturation or cut off) indicators never stay on,
but that they do so at most to the beat of the lowest sound frequencies. Otherwise
the amplified signal will be distorted with low quality and low integibility.
MUTE
: This lights up when the
MUTE
function is active (silent mode)
ON/STBY
: the green light comes on when the equipment is in normal operating
mode and it goes orange when it is in standby or low consumption mode
(STANDBY).
LEVEL:
This flashes when you adjust the general level of the device. It also lights
up during special adjustment modes, input levels (see section
4.2. Special active
source selection mode and setting adjustments
)
Содержание CA40
Страница 1: ...USER MANUAL MANUAL DE INSTRUCCIONES NOTICE D UTILISATION BEDIENUNGSANLEITUNG CA40 ...
Страница 2: ......
Страница 13: ...13 7 DIAGRAM OF FUNCTIONS ...
Страница 14: ...14 ...
Страница 25: ...25 7 DIAGRAMA DE FUNCIONES ...
Страница 26: ...26 ...
Страница 37: ...37 7 SCHÉMA DE FONCTIONS ...
Страница 38: ...38 ...
Страница 49: ...49 7 FUNKTIONSDIAGRAMM ...
Страница 51: ...51 9 BLOCK DIAGRAM 9 DIAGRAMA DE BLOQUES 9 SCHÉMA FONCTIONNEL 9 BLOCKSCHALTBILD ...