10
6. MAIN SCREEN/PRESET MANAGEMENT
After powering up the unit, its main screen displays the name or label of the device (default is
ALMA26) on the top line of text. The lower line shows the number and name (LABEL) of the active
preset or template:
An asterisk to the right of the preset number indicates that it has been modified and not yet saved
in the memory of the ALMA26.
6.1. RECALL PRESET MENU
The ALMA26 has 6 operating templates, which are used as a starting point for the configuration
of an operating mode:
o
T1:
3 x 1 stereo way
o
T2:
2 stereo ways + 1 stereo way
o
T3:
3 stereo ways
o
T4:
4 mono ways + 2 mono auxiliaries
o
T5:
5 mono ways + 1 mono auxiliary
o
T6:
6 mono outputs
It is therefore possible to recall one of these templates, to edit its parameters and save the
resulting setup as a PRESET or user memory.
System templates are displayed on the screen with the Txx prefix, where xx is the template
number (between 01 and 06), followed by its name or LABEL. These files are not rewritable.
User presets are displayed on the screen with the Pxx prefix, where xx is the preset number
(between 01 and 20), followed by its name or LABEL. The default name of all user presets is USER
PRESET, but it can be modified when you save one of them in memory.
The procedure for recalling a preset or a user template is the following one:
From the main menu, press SHIFT + RECALL
The RECALL PRESET message is displayed and a preset number is flashing
R E C A L L P R E S E T
[ P 0 4 ] S T E R E O
3 W A Y
Select the preset or template using the rotary control, and then select one of the two
following options:
Press SHIFT + RECALL to validate the selection and activate the new preset, bringing
you back to the main screen, this time with data from the new active preset
Or
Press SHIFT + CANCEL to cancel the selection and display again the preset from the
selection list
Pressing SHIFT + EXIT at any point during the above process cancels the selection and brings
the main screen back.