background image

 

11 

 

6.3. Front panel volume controls 

The  front  panel  features  four  volume  knobs,  one  per  channel,  allowing  independent 
adjustment of the maximum output level for each amplifier channel. 

Remote control ports also allow to adjust the volume of each amplifier channel from a 
WPm series panel, a potentiometer or other external hardware device; the actual volume 
of each channel is the result of the two volume controls position (front panel and remote 
control). 

In the device packaging, you’ll find a bag with clear caps to be inserted on the front panel 

knobs.  They  protect  the  input  attenuation  settings  from  unsolicited  tampering.  Once 
inserted, you must use a flathead screwdriver or a similar tool to remove them. 

6.4. AUTO STBY ON/OFF switch

 

Switch  (39)  that  enables/disables  the  auto  standby  mode  (sleep  or  low  consumption 
mode).  If  this  function  is  activated,  the  amplifier  will  switch  to  standby  after 
approximately two minutes without any input signal detected. When an input signal is 
re-detected, the amplifier automatically switches back to normal operating mode. 

 

CLEANING 

The front panel should not be cleaned with dissolvent or abrasive substances because 
silk-printing could be damaged. To clean it, use a soft cloth slightly wet with water and 
neutral liquid soap; dry it with a clean cloth. Be careful that water never gets into the 
amplifier through the holes of the front panel.

 

 

 

Содержание HZA4-120F

Страница 1: ...50 0241 0105 HZA4 120F EN HZA4 120F AMPLIFIERS Flexi power Amplifier USER MANUAL ...

Страница 2: ...the FLEXIPOWER function 8 5 5 Internal switches for high pass filters 9 5 6 Remote control ports for attenuation 9 5 7 REMOTE CONTROL ports connection 9 OPERATION AND USAGE 10 6 1 Start up 10 6 2 Front panel LED indicators 10 6 3 Front panel volume controls 11 6 4 AUTO STBY ON OFF switch 11 CLEANING 11 CONTROL PANEL FUNCTIONS 12 8 1 Front Panel 12 8 2 Rear Panel 13 DIAGRAMS 14 9 1 Configuration Di...

Страница 3: ...e of important operating and maintenance servicing instructions in the literature accompanying the appliance WARNING If applicable The terminals marked with symbol of may be of sufficient magnitude to constitute a risk of electric shock The external wiring connected to the terminals requires installation by an instructed person or the use of ready made leads or cords WARNING To prevent fire or sho...

Страница 4: ...s or when unused for long periods of time 13 Refer all servicing to qualified personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 14 Disconnecting from mains When sw...

Страница 5: ...endent volume adjustment per channel through front panel controls Independent per channel 0 10 VDC remote volume control via screw terminals on rear panel SPM 100 Technology Channel N for direct high impedance amplification 100V line without output transformers which has the following benefits compared to traditional 100V line amplification with transformers o Better frequency response in the low ...

Страница 6: ...t upon these ones 5 2 Mains connection The HZA4 120F amplifiers are fed with alternate currents depending on the country of 110 120 220 240V 47 63Hz see characteristics in the back of the unit The amplifier should have an earth connection in good conditions earth resistance Rg 30 or less The environment must be dry and dustless Do not expose the unit to rain or water splashes and do not place liqu...

Страница 7: ... signal Pin COLD or inverted signal Pin GROUND Pin For unbalanced connection short circuit pin to pin TACK outputs 42 44 available for inputs 1 and 2 are parallel to the input and serve to re send the signal of these inputs INPUTS CH1 CH2 to other input channels amplifiers or sound systems The input impedance is 20K balanced with a nominal input sensitivity of 0dBV 1V This impedance makes possible...

Страница 8: ... on the front panel between the pair of channels will be lit o The audio content of the pair of channels becomes the sound source connected to the input of the channel with a lower number input 1 for channel pair 1 2 input 2 for channel pair 2 3 input 3 for channel pair 3 4 o The active front and remote volume control if used of the channel pair becomes that of the channel with a lower number cont...

Страница 9: ...f affected channels The maximum level of each amplification channel and therefore its output volume that can be reached by the remote attenuator is determined by the position of its front knob 21 22 23 24 5 7 REMOTE CONTROL ports connection The signal remote attenuation level for each input channel can be set by using 3 types of external devices connected to the rear panel REMOTE CONTROL ports a U...

Страница 10: ...s illuminate when the input signal exceeds 35dB Overload indicators OVL 3 8 13 18 illuminate when the channel reaches its maximum power capacity due to a too low load impedance CLIP indicators 4 9 14 19 illuminate when the speakers output signal is close to the actual clipping level The CLIP system takes into account possible fluctuations in the supply voltage if they exist always giving a real in...

Страница 11: ...settings from unsolicited tampering Once inserted you must use a flathead screwdriver or a similar tool to remove them 6 4 AUTO STBY ON OFF switch Switch 39 that enables disables the auto standby mode sleep or low consumption mode If this function is activated the amplifier will switch to standby after approximately two minutes without any input signal detected When an input signal is re detected ...

Страница 12: ... CH 2 9 Clip indication CLIP CH 2 10 Thermal protection indicator TH CH 2 11 Merge indicator MERGE 2 3 12 Signal presence SP CH 3 13 Overload indicator OVL CH 3 14 Clip indication CLIP CH 3 15 Thermal protection indicator TH CH 3 16 Merge indicator MERGE 3 4 17 Signal presence SP CH 4 18 Overload indicator OVL CH 4 19 Clip indication CLIP CH 4 20 Thermal protection indicator TH CH 4 21 Volume CH 1...

Страница 13: ...Screwable terminal for remote control CH 4 36 Screwable terminal for remote control CH 3 37 Screwable terminal for remote control CH 2 38 Screwable terminal for remote control CH 1 39 Standby mode selector AUTO STBY 40 Input terminals channel 4 CH 4 41 Input terminals channel 3 CH 3 42 Output terminals to other amplifiers STACK CH 2 43 Input terminals channel 2 CH 2 44 Output terminals to other am...

Страница 14: ...14 DIAGRAMS 9 1 Configuration Diagram 9 2 Block Diagram off on FACTORY ADJUST High Pass Filter ON ...

Страница 15: ...0 03 typ 0 2 max Signal Noise Ratio 100V 90dB Channel Crosstalk 1kHz 100V 90dB Inputs Sensitivity nom Impedance 0dBV 20kW Connectors Terminal Block Symmetrical Outputs Connectors Terminal Block Indicators Power Green ON Red Standby Signal Present Clip Overload Thermal 35dB Yes Yes Yes Remote control DC 0 10V 0 1A max No attenuation 0V Full attenuation 10V Connectors Terminal block Auto power Thres...

Страница 16: ...ght to make changes or improvements in the design or manufacturing that may affect these product specifications For technical queries contact your supplier distributor or complete the contact form on our website in Support Technical requests Motors 166 168 08038 Barcelona Spain 34 932238403 information ecler com www ecler com ...

Отзывы: