14
The PAGER ports are used for point to point connection to 2 eMPAGE messaging
consoles, through which it is possible to perform functions such as real-time voice
calls (paging) to output zones within the installation, using a priority module on
the eMIMO1616 unit which fades or fully mutes the sound content of the existing
program in those zones at the time of the action.
A standard (crossover) CAT5 or higher cable, with an RJ45 connector on each end,
connects a messaging console point to point to either of ports A or B on the unit,
through which the remote DC supply for the console, control data, and balanced
audio from the messaging console microphone can be transmitted.
A maximum of 2 consoles is allowed; one connected to the PAGER A port, and the
other to the PAGER B port, with each one using a PAGER priority module on the
eMIMO1616 unit.
Note:
it is it not possible to perform
the following connections simultaneously
,
and the connections listed below are mutually
exclusive
:
a messaging console to the PAGER A port + an audio signal to the INPUT7
Euroblock connector
a messaging console to the PAGER A port + an audio signal to the INPUT7
Euroblock connector
The total number of PAGER (to messaging console) or DUCKER (without
messaging console) priority modules for the eMIMO1616 is 4, assignable to the
local inputs 5 to 8. These 4 modules may be activated or deactivated, and each of
them may use one of the 2 available priority levels, so that the signals with greater
priority will fade the program signal selected in the destination zone, in addition to
the signals of lesser priority sent to these zones, if there are any, at the time when
the maximum priority module is activated.
See the eMIMO1616 web application manual to find out more about programming
the PAGER / DUCKER priority modules.