Pin and Terminal Assignments of UA 410 L
51
Firmware V1.50 - Doku 2.0 06. April 2016
If 230 V AC voltage is present at digital input, the associated red LED lights,
see chapter 5.5.1 Status LEDs for details.
6.6
Terminal assignment of the 0..10 V analogue outputs
This functionality is currently not used!
Warning - hazardous electrical voltage!
Connecting mains power to the analogue outputs will lead
to the destruction of the controller!
Malfunctions due to interference sources:
All leads running to and from the case controller must
be shielded (cable type: LiYCY)! No shielding is required on sensor leads when installed exclusively
inside the refrigerated display case and when external interference (for example from parallel power
wires) is not to be expected (see operating instruction “Basics and General Safety and Connection
Instructions”). As a general rule, care should be taken to ensure that signal leads and leads carrying
a supply voltage are routed through separate cable channels.
ZNG:112 830 DEF1
0..10 V
10
1
D32
D31
D22
D21
D12
D11
73
74
43
44
63
64
53
54
2
1
3
4
CAN-GND
CAN-LOW
CAN-HIGH
SHIELD
D42
D41
GND
AO2
GND
AO1
5
0
2
3
1
4
6
7
8
9
5
0
2
3
1
4
6
7
8
9
CAN-BUS
ADDRESS
1..99
V
V
+
+
-
-
AO1
AO2
PE (SHLD)
31
32
30 29
Controller
Type
Terminal No.
Analogue output 2
Analogue output 1
All controllers
32
GND
--
31
AO2 (+ 0..10 V)
--
30
--
GND
29
--
AO1 (+ 0..10 V)
Содержание UA 410 L Case Controller
Страница 30: ...Function of UA 410 L 24 Firmware V1 50 Doku 2 0 06 April 2016 Notice...
Страница 52: ...Installation and Startup of UA 410 L 46 Firmware V1 50 Doku 2 0 06 April 2016 Notice...
Страница 72: ...Operation of UA 410 L 66 Firmware V1 50 Doku 2 0 06 April 2016 Notice...
Страница 80: ...Menu Structure of UA 410 L 74 Firmware V1 50 Doku 2 0 06 April 2016 Notice...
Страница 82: ...Decommissioning and disposal 76 Firmware V1 50 Doku 2 0 06 April 2016 Notice...
Страница 92: ...Order numbers and accessories of UA 410 L 86 Firmware V1 50 Doku 2 0 06 April 2016 Notice...