ECI MOVFR-LCD Installation Manual
Electronic Controls, Inc.
7073 North Atlantic Ave. Cape Canaveral, FL 32920
800-633-9788
P a g e
|
14
•
OP decel –
A lower value produces a quicker deceleration. This should be set so the OP Final
Speed FSO is reached before the DOL and OPEN stop roller to prevent slamming and bouncing.
The default setting is 50. Min is 1 and max is 100.
•
OP torque –
Default setting is 15. Min is 1 and max is 100.
•
OP hold torq. –
Enabled when the door reaches DOL and parameter is set to a value greater than
0. Together with OP Hold sp will prevent the door from drifting out of the DOL. Default setting
is 0. Min is 0 and max is 100.
CAUTION
:
Holding power should be set less than 15W to prevent motor heating
which will reduce motor life.
•
OP hold sp. –
Enabled when the door reaches DOL and the parameter is greater than 0. Together
with the OP Hold Tq will prevent the door from drifting out of the DOL. Default setting is 0.
Min is 0 and max is 100.
CAUTION
:
Holding power should be set less than 15W to prevent motor heating
which will reduce motor life.
5.1.5.1.2
Heavy Door Parameter settings with defaults
The heavy door parameters are enabled when the HEAVY input is valid during AUTO operation and
when the HEAVY switch is on in MANUAL operation. These parameters are the same as the standard
parameters so only the default and range settings are listed.
•
HCL hold torq. –
Default setting is 0. Min is 0 and max is 100.
•
HCL hold sp. –
Default setting is 0. Min is 0 and max is 100.
•
HCL torque –
Default setting is 15. Min is 1 and max is 100.
•
HCL high speed – HSC -
Default setting is 35. Min is 1 and max is 100.
•
HCL final speed – FSC -
Default setting is 25. Min is 1 and max is 100.
•
HCL nudge speed –
Default setting is 30. Min is 1 and max is 100.
•
HCL accel –
Default setting is 100. Min is 1 and max is 255.
•
HCL decel –
Default setting is 100. Min is 1 and max is 255.
•
HOP quick stp re –
Default setting is 20. Min is 1 and max is 100.
•
HOP slow start –
Default setting is 25. Min is 1 and max is 100.
•
HOP high Speed – HSO -
Default setting is 45. Min is 1 and max is 100.
•
HOP medium speed – MSO -
Default setting is 35. Min is 1 and max is 100.
•
HOP final speed – FSO -
Default setting is 25. Min is 1 and max is 100.
•
HOP accel –
Default setting is 100. Min is 1 and max is 100.
•
HOP decel –
Default setting is 50. Min is 1 and max is 100.
•
HOP torque –
Default setting is 1. Min is 1 and max is 100.
•
HOP hold torq –
Default setting is 0. Min is 0 and max is 100.
•
HOP hold sp. –
Default setting is 0. Min is 0 and max is 100.