SSO –
Slow Start Open. Speed setting is
OP slow start
. When illuminated indicates the start of
the open cycle when the interlock rollers unlock hoistway door. SSO/FSO sensor blocked and
MSO sensor open during an OPEN cycle.
•
HSO –
High Speed Open. Speed setting is
OP High Speed.
When illuminated indicates High
speed open. SSO/FSO and MSO sensors open during an OPEN cycle.
•
MSO –
Medium Speed Open. Speed setting is
OP medium sp.
When Illuminated indicates
Medium Speed open. SSO/FSO sensor open and MSO sensor blocked during an OPEN cycle.
•
FSO –
Final Speed Open. Speed setting is OP final speed. Illuminated during Final speed open
when SSO/FSO and MSO sensors are blocked during an OPEN cycle.
•
HOLDING –
Illuminated when DCL or DOL sensors are blocked (fully OPEN or CLOSED
positions) and
CL/OP hold torq
and
hold sp
parameter settings are greater than 0
•
NUDGE –
Nudge speed
.
Speed setting is
Nudge
. Illuminated when CLOSE and NUDGE inputs
are active.
•
HSC –
High Speed Close. Speed setting is
CL high speed
. Illuminated during High speed close
when FSC sensor is open during a CLOSE.
•
FSC –
Final Close Speed. Speed setting is
CL final speed
. Illuminated during final close speed
when FSO sensor is blocked during a CLOSE.
•
AUX –
Illuminated when AUX sensor is blocked
•
DPM –
Illuminated when DPM sensor is blocked
•
DOL –
Door Open Limit. Illuminated when DOL sensor blocked
•
DCL –
Door Close Limit. Illuminated when DCL sensor is blocked
•
STALL REVERSE – Not used
•
FREQUENCY FAILURE -
•
REOPEN DEVICE –
Illuminated when the REOPEN relay is energized via the light curtain
inputs.
•
FAULT –
Illuminated when there is a communications failure between Control and Drive boards
•
POWER –
Illuminated when power to board is good.
5.1.3.3
Keypad
•
+
Button - This button moves the curser up in the screen for selecting menus or parameters and
increases the number of the setting being programmed
•
-
Button - This button moves the curser down in the screen for selecting menus and decreases the
number of the setting being programmed
•
Enter
Button - The ENTER button selects the menu or parameter indicated by the curser and
enters the current number of the parameter being programmed.
•
ESC
Button - The ESC button is used to move back to the previous menu
5.1.3.4
Switches
•
RUN / CAM SETUP –
2 position switch.
RUN position is for normal operation. CAM SETUP
allows for adjusting CAMs with valid inputs to OPEN, CLOSE etc. without moving the doors.