ECI 1000-U LCD Installation Manual
Electronic Controls, Inc.
7073 North Atlantic Ave. Cape Canaveral, FL 32920
800-633-9788
P a g e
|
9
6.3
User Interface
6.3.1
Toggle switches
Run/Test
– Two position switch. In
RUN
position the door board is controlled through the
controller interface. In the
TEST
position door operation is controlled through the
OPEN/CLOSE
switch.
OPEN/CLOSE
– 3 position switch. Middle position if off. With the
RUN/TEST
switch in the
TEST
position door operation can be controlled with this switch.
NUDGE/LOCK
– 3 position switch. Middle position if is off. With the
RUN/TEST
switch in
the
TEST
position both
NUDGE
and
LOCK
are controlled through this switch.
6.3.2
Keypad
+ button
– Used to move curser up or increase speed settings
- button
– Used to move curser down or decrease speed settings
ENTER
- Used to select menu options or enter parameter settings
ESC
– Used to exit menu or go to previous menu
6.3.3
LED Indicators
CL –
On when CAM is on CL switch
DO17 -
On when CAM in on CL switch
OL -
On when CAM in on OL switch
OSDL -
On when CAM in on OSDL switch
PL –
On when CAM in on the PL switch
CLX –
On when CAM in off the CLX switch
OLX –
On when the CAM is off the OLX switch
SS –
On when the CAM is on the SS switch
HDCSDL –
On when cam is on switch
DO4 –
On when DO4 present
DO7 –
On when DO7 present
DO18 –
On when DO18 present
6.3.4
Main Menu
Figure 1 - Main Menu
ECI Model 1000N
(C) 2015 ECI, Inc.
Edit parameters
Load defaults
Diagnostics
Technical support