6.2.3
X13 Controller interface
The voltage of controller interface signals are adjustable through the
Input Voltage
parameter located
under the
Edit Parameters
menu. These signals are AC/DC compatible.
DO3
– Open limit output to controller
DO10
– Open command input
DO7
– Close command input
DO4
– Nudging command input
DO18
– Door locking command input
DO17
– Close limit output to controller
6.2.4
X9 Connections
0V
– Negative or return voltage for 54P from operator
54P
- +54VDC power source from operator
RB1
and
RB2
- External braking resistor located in operator
A1
and
A2
– 48VDC output to motor
6.2.5
X4 and X5 connections
CAM switch assembly connectors. Refer to Figure 5 – CAM Switch Wiring
6.2.6
X7 and X10 Connectors
Heavy Door option connectors. These 2 connectors are the same pinout located on opposite sides of the
board for installation convenience.
24P – +
24VDC power output
HDP –
Heavy door +24VDC input
HDN –
Heavy door 24VDC common input
0V –
24VDC common output
6.2.7
X8 Infra-red Door Detector Connections
Compatible with Memco model 640. Dry relay contacts to controller 250VAC/3A, 24VDC/3A
24P
HDP
HDN
0V
EXAMPLE
USING
DRY CONTACT
LINK
NO
NC
COM
TRIG
0V
24P
X8
RELAY
TX
RX
ORG
WHT
BLU
ORG
WHT
BLU
RED