background image

<

 

Pulsports T-101/T-201

                                               

 

 

 

Countdown timer mode

 

1. Press ST/SP to start/stop countdown timer. 
2. There will be a 10 seconds beep when the function is completed, 

and 

OVEr

 will display on the LCD. 

3. Stop beep and reload pre-set data by pressing any key. 
4. Reload pre-set date at any time by pressing T.MODE 2 seconds. 
5. Maximum range for countdown timer is 99H59M59S. 
6. 

Countdown timer setting:

 

a). Press T.MODE to change to “

TMR

” mode. 

b). Press SET 2 seconds to enter countdown timer setting mode. 
c). Press T.MODE or ST/SP to set timer On or Off. 
d). Refer the 

Data Setting Processes

 to adjust the Timer data. 

 

 

Alarm mode

 

1. Press ST/SP to change alarm sets (1 to 3). 
2. The “

” symbol will display after alarm setup. 

3. The alarm is a 30 seconds beep, the “

” symbol will blink. 

4. Stop the beep by pressing any key. 
5. Take note of the time mode you have selected 12H or 24H. 
6. 

Alarm setting:

 

a). Press T.MODE to change to “

ALM

” mode. 

b). Press SET 2 seconds to enter alarm setting mode. 
c). Press T.MODE or ST/SP to select setting alarm. 
d). Refer the 

Data Setting Processes

 to adjust the Alarm data. 

e). Press T. MODE or ST/SP to set ALARM ON/OFF. 
f). Repeat steps

 c).

 to step 

e).

 to set the other alarm data. 

 

E-8 

 

 

 

Содержание Elite T101

Страница 1: ...Mode 8 Alarm Mode 8 Date Mode 9 Lap Mode 30Sets 9 Lap Recall Mode 30Sets 9 Chronometer Mode 9 10 HEART RATE FUNCTION DESCRIPTIONS 11 Start Stop Heart Rate Measure Function 11 Start Stop Heart Rate Data Record Function 11 Reset Heart Rate Record Data 11 Heart Rate Display Description 11 Newest Design Change Display for BPM and HR 12 Target Zone Mode 12 Stop Watch Mode 13 Calories Mode 13 Exercise T...

Страница 2: ...USER MANUAL E 1 ...

Страница 3: ... Pulsports T 101 T 201 E 2 T 101 T 201 PARTS Your PULSPORTS consists of four parts 1 ELASTIC STRAP 2 Cable Ties X 3 3 BRICKET FOR BICYCLE 4 T 101 T 201 MAIN 5 TRANSMITTER d c f e g ...

Страница 4: ... Pulsports T 101 T 201 INSTALLATION How to wear the chest belt E 3 ...

Страница 5: ...nce transmission should be less than 1 meter 3 feet 5 Do not bend or fold the chest belt to preventing damage Fig 7 KEY OPERATION Basic key operations z SET Hold 2 seconds to enter data setting mode z T MODE Change watch function group z E MODE Change pulse function group z ST SP Start Stop z LAMP EL Light light 3 seconds for each press z BEEP Hold 2 seconds to on off chime and key beep z LAP Reco...

Страница 6: ...ULATION Fig C DATA SETTING PROCESSES 1 Press E MODE to change the setting valua 2 Press T MODE to increase the value hold to increase the value automatically 3 Press ST SP to decrease the value hold to decrease the value automatically 4 Press SET to complete setting and quit ...

Страница 7: ...HR 2 DIGITAL INTENSITY Calculate your Heart beat intensity current HR Max HR 100 automatically according to your personal data input 3 TARGET ZONE Target Zone setup for intensity which has 6 sets 4 STW Stop watch 00H00M00S to 99H59M59S from the heart rate data record function start 5 CAL Calculate expended calories during exercise 0 to 9999 99 Kcal according to your personal data input T 201 Only ...

Страница 8: ...p function On Off by press ST SP 2 seconds The symbol display means Chime and Key beep function on 3 Clock setting a Press T MODE to change to CLOCK mode b Press SET 2 seconds to enter clock setting mode c Press E MODE to change the setting value d Press T MODE to increase the value hold to increase the value automatically e Press ST SP to decrease the value hold to decrease the value automaticall...

Страница 9: ... mode c Press T MODE or ST SP to set timer On or Off d Refer the Data Setting Processes to adjust the Timer data Alarm mode 1 Press ST SP to change alarm sets 1 to 3 2 The symbol will display after alarm setup 3 The alarm is a 30 seconds beep the symbol will blink 4 Stop the beep by pressing any key 5 Take note of the time mode you have selected 12H or 24H 6 Alarm setting a Press T MODE to change ...

Страница 10: ...rt stop Lap function 3 The lap mode can record 30 sets data 4 It will overwrite when record data over 30 sets 5 Press LAP to record current lap data and start next lap data 6 When press LAP the record data will hold 3 seconds for user to read it Lap Recall mode 30SETS T 201 Only 1 Press T MODE to change to LP R mode 2 Press ST SP to recall the record data hold to increase automatically 3 Press T M...

Страница 11: ... Pulsports T 101 T 201 E 10 ...

Страница 12: ...s E MODE to change to STW function 3 Press ST SP the signal shown as at the middle of the display will change to it means the data record function is started Stop by pressing ST SP the signal will change to 4 AVG STW CAL EX T WT L FT L and MAX functions will only work while the record function is on CAL WT L and FT L T 201 Only 5 CAL WT L and FT L mode will be calculated when the heart rate is equ...

Страница 13: ... 1 Press ST SP to change to next target zone set 2 and will not display when the heart rate within the target zone No Beep sound 3 will display when the heart rate is below the lower limit of the target zone Beep should sound 4 will display while the heart rate is above the upper limit of target zone Beep should sound 5 Target zone setting a Press E MODE to change to T Z mode b Press SET 2 seconds...

Страница 14: ...se time mode EX T 1 Calculation and recording the exercise time starting when the heart rate over the lower limit of the target zone 2 Total efficient exercise time will be recorded including the time in and above the target zone 3 The exercise time records ranges from 00H00H00S to 99H59M59S 10 Weight loss mode WT L 1 Caluates the weight loss during exercies lncluding the consumption of carbohydra...

Страница 15: ...s to enter user date setting mode c Press E MODE to change setting mode d Press T MODE or ST SP to change Sexuality male or female e Press T MODE or ST SP to change Age f Press T MODE or ST SP to change Weight Units kg or lb g Press T MODE or ST SP to change Weight data h Press T MODE or ST SP to change heart rate maximum 100 to 220 bpm i Refer the Data Setting Processes to adjust the User data Re...

Страница 16: ... and high tension distribution line etc Because the radio signal will be affected under the environment as high voltage and strong magnetic field 5 Although the water resist of this watch has been approved as 30 meter but please do not operate any button of the watch under water This watch is not designed for diving 6 Battery can be used for 1 year according to daily use for 2 hours Please change ...

Отзывы: