E1 

ENGLISH

 

Index 

 

1. 

ELITE T-301 PARTS

 .................................................................... E2 

2. 

INSTALLATION

 ............................................................................ E3 

How to wear the chest belt? ...................................................... E3 

3. 

KEY OPERATIONS

 ...................................................................... E4 

Time mode circulation ............................................................... E5 

Pulse mode circulation .............................................................. E5 

Data setting processes .............................................................. E5

 

4. PULSPORTS FUNCTIONS

 .......................................................... E6

 

Watch Functions ........................................................................ E6 

Heart Rate Functions ................................................................. E6 

5. 

WATCH FUNCTION DESCRIPTIONS

 ......................................... E7 

Clock Mode ................................................................................ E7 

Countdown Timer Mode ............................................................. E8 

Alarm Mode ............................................................................... E8 

Data Mode ................................................................................. E9 

Lap mode (30SETS) ................................................................ E10 

Lap Recall mode (30SETS) ..................................................... E10 

Chronometer Mode .................................................................. E10 

6. HEART RATE FUNCTION DESCRIPTIONS

 ............................... E11 

Start/Stop Heart Rate Measure Function ................................. E11 

Start/Stop Heart Rate Data Record Function ........................... E11 

Reset Heart Rate Record Data ................................................ E11 

Heart Rate Display Descriptions .............................................. E11 

Newest Design: Change Display for BPM and %HR ............... E12 

Target Zone Mode (

T-Z

) ............................................................ E12 

Stop Watch Mode (

STW

) ......................................................... E13 

Calories Mode (

CAL

) ............................................................... E13 

Exercise Time Mode (

EXT

) ...................................................... E13 

Calories Per Hour Mode (

C/H

) ................................................. E13 

Weight Loss Mode (

WT-L

) ....................................................... E13 

%Fat Loss Mode (

%FT

) ........................................................... E14 

Ft.los Mode (

FT.L

) ................................................................... E14 

Maximum Mode (

MAX

) ............................................................ E14 

In Target Zone Time Mode (

IN.T

) ............................................. E14 

Over Target Zone Mode (

OV.T

) ............................................... E14 

User Data Mode (

USR

 ) ........................................................... E14 

Total Fat Loss Mode (

T.FT

) ...................................................... E15 

Total Calories Mode (

T.CA

) ...................................................... E15 

Average Mode (

AVG

) .............................................................. E16 

7. 

PRECAUTIONS

 ......................................................................... E16 

8. 

SPECIFICATIONS

 ...................................................................... E16 

Содержание ELITE T-301

Страница 1: ...SCRIPTIONS E11 Start Stop Heart Rate Measure Function E11 Start Stop Heart Rate Data Record Function E11 Reset Heart Rate Record Data E11 Heart Rate Display Descriptions E11 Newest Design Change Display for BPM and HR E12 Target Zone Mode T Z E12 Stop Watch Mode STW E13 Calories Mode CAL E13 Exercise Time Mode EXT E13 Calories Per Hour Mode C H E13 Weight Loss Mode WT L E13 Fat Loss Mode FT E14 Ft...

Страница 2: ...E2 T 301 PARTS Your PULSPORTS consists of four parts 1 ELASTIC STRAP 2 CABLE TIES X 3 3 BRACKET FOR BICYCLE 4 T 301 MAIN 5 TRANSMITTER ...

Страница 3: ... Pulsports T 301 P E3 INSTALLATION How to wear the chest belt ...

Страница 4: ...ion The distance transmission should be less than 1 meter 3 feet 5 Do not bend or fold the chest belt to preventing damage Fig 7 KEY OPERATIONS Basic key operations SET Hold 2 seconds to enter data setting mode T MODE Change watch function group E MODE Change pulse function group ST SP Start Stop LAMP EL Light light 3 seconds for each press BEEP Hold 2 seconds to on off chime and key beep LAP Reco...

Страница 5: ...LATION Fig C DATA SETTING PROCESSES 1 Press E MODE to change the setting valua 2 Press T MODE to increase the value hold to increase the value automatically 3 Press ST SP to decrease the value hold to decrease the value automatically 4 Press SET to complete setting and quit ...

Страница 6: ...FUNCTIONS 1 Display the current heart rate HR 2 DIGITAL INTENSITY Calculate your Heart beat intensity current HR Max HR 100 automatically according to your personal data input 3 TARGET ZONE Target Zone setup for intensity which has 6 sets 4 STW Stop watch 00H00M00S to 99H59M59S from the heart rate data record function start 5 CAL Calculate expended calories during exercise 0 to 9999 99 Kcal accord...

Страница 7: ...imum heart rate for intensity calculate 100bpm to 220bpm 15 T FT Total fat lost from exercise weekly or monthly option 0 to 9999 99g 16 T CA Total Kcal expenditure weekly or monthly calories consumption can be calculated 0 to 999999 Kcal 17 AVG Average HR during exercise 40 to 240 bpm bpm beaps per minute 40 to 240 WATCH FUNCTION DESCRIPTIONS CLOCK MODE 1 12H or 24H switchable 2 Turn Chime and Key...

Страница 8: ... Pulsports T 301 P E8 f Press T MODE or ST SP to select 12H or 24H mode g Press T MODE or ST SP to reset the seconds to 00 h Press SET to complete setting and quit ...

Страница 9: ...ng T MODE 2 seconds 5 Maximum range for countdown timer is 99H59M59S 6 Countdown timer setting a Press T MODE to change to TMR mode b Press SET 2 seconds to enter countdown timer setting mode c Press T MODE or ST SP to set timer On or Off d Refer the Data Setting Processes to adjust the Timer data Alarm mode 1 Press ST SP to change alarm sets 1 to 5 2 The symbol will display after alarm setup 3 Th...

Страница 10: ... d Refer the Data Setting Processes to adjust the Alarm data e Press T MODE or ST SP to set ALARM ON OFF f Repeat steps c to step e to set the other alarm data Date mode 1 Calendar from the year 2000 to 2099 2 Day of week will display automatically while the date is input 3 Date setting a Press T MODE to change to DAT mode b Press SET 2 seconds to enter date setting mode c Refer the Data Setting P...

Страница 11: ...urrent lap data and start next lap data 6 When press LAP the record data will hold 3 seconds for user to read it Lap Recall mode 30SETS 1 Press T MODE to change to LP R mode 2 Press ST SP to recall the record data hold to increase automatically 3 Press T MODE 2 seconds to clear all lap data Chronometer mode 1 Press ST SP to start stop chronometer 2 Press T MODE 2 seconds to reset chronometer data ...

Страница 12: ...T SP the signal shown as at the middle of the display will change to it means the data record function is started Stop by pressing ST SP the signal will change to 4 AVG STW CAL EX T C H WT L FT FT L and MAX functions will only work while the record function is on 5 C H and FT will be displayed automatically when heart rate is measured The value will become while no pulse is detected 6 CAL C H WT L...

Страница 13: ...he data you input 1 Press ST SP to change to next target zone set 2 and will not display when the heart rate within the target zone No Beep sound 3 will display when the heart rate is below the lower limit of the target zone Beep should sound 4 will display while the heart rate is above the upper limit of target zone Beep should sound 5 Trget zone setting a Press E MODE to change to T Z mode b Pre...

Страница 14: ...he range is from 0 Kcal to 9999 99 Kcal 9 Exercise time mode EX T 1 Calculation and recording the exercise time starting when the heart rate over the lower limit of the target zone 2 Total efficient exercise time will be recorded including the time in and above the target zone 3 The exercise time records ranges from 00H00H00S to 99H59M59S 10 Calories per hour mode C H 1 Calculates the expended cal...

Страница 15: ...ss 6 The range of fat percentage is from 0 to 70 13 Ft los mode FT L 1 Calculates the weight of fat lost during exercise 2 The actual weight of fat lost from exercise can be important and it is a valuable reference of weight loss 3 The range of fat loss is from 0 to 9999 99 g 14 Maximum mode MAX 1 Monitors and records the maximum heart rate during exercise 2 The range of maximum heart rate is from...

Страница 16: ...ess T MODE or ST SP to change Weight data h Press T MODE or ST SP to change heart rate maximum 100 to 220 bpm i Refer the Data Setting Processes to adjust the User data Refer Fig E FIG E USER DATA SETTING 18 Total fat loss mode T FT 1 Records the total cumulative weight of fat lost 2 Unless this value is reset the data will be saved separately so weekly or monthly cumulative weight of fat lost can...

Страница 17: ... measured signal 4 Avoiding using the heart rate monitor close to trolley car tram stop transformer electric substation and high tension distribution line etc Because the radio signal will be affected under the environment as high voltage and strong magnetic field 5 Although the water resist of this watch has been approved as 30 meter but please do not operate any button of the watch under water T...

Отзывы: