40
Chapter 2 •
Configuration via Web UI
3500834-0001 Revision C
To activate the security feature, select “Password Protection” On, enter the same
password string in both fields and press “Apply”. If the two password fields match,
the password is saved and security is enabled.
The UT will be locked when it restarts, or to immediately lock it, press “Lock Unit”
Make a note of the password as it cannot be viewed and once the UT is locked it
cannot be accessed.
To deactivate the security feature, select “Password Protection” Off and press
“Apply”.
If the Web UI is accessed when the UT is locked, the browser is redirected to the
Login page and the password must be entered. If the wrong password is entered
three times in a row, password entry is locked out and the UT must be restarted
before the password will be accepted.
Figure 26: Login page