PRODUCTION
page 41
f) Select Command 117 and adjust SYMM so points just close.
g) Retest 3b and 3f and adjust if needed.
3. Adjust remaining offsets:
a) Select pattern 59 and set wipe lever to 50. Select Command 119.
Adjust SYMM to center pattern (horizontal start offset)
b) Select pattern 60 and set wipe lever to 50. Select Command 120.
Adjust SYMM to center pattern (vertical start offset)
4. Adjust patterns 53, 54, 55, 56, 59, 60 (NOT 57 or 58!)
a) Select pattern 53 in N/R mode, set the wipe lever to 005 (NOT 0),
select Command 117 and adjust the SYMM knob until the wipe
just disappears.
b) Repeat with patterns 54, 55, 56, 59, and 60.
When you have finished with these calibrations, test them with all rotary
wipes. If all wipes are good, save user calibration values using Command
401. If calibration is disturbed later, you can restore this set with Command
400.
Calibration registers
200 Reload original factory calibration
The factory saves a set of calibration values in battery- backed-up RAM. It
can be restored with Comm 200 if improper calibration is suspected.
400 Restore user calibration registers
401 Save user calibration registers
If you would like to experiment with a calibration setting without risk of
making it worse, first save the current calibration registers with Command
401. Then the 100 series commands are used to recalibrate, and if the result
is unacceptable the user set can be recalled with Command 400.