PRODUCTION
page 37
Calibration commands
The MVS3 has about 40 computer-generated voltages which substitute for conventional
trimmers. The commands below can be used to recalibrate the unit from the front panel.
There are four sets of calibration registers. The current set is permanently changed when
a calibration command is adjusted, and can be saved in the user set with Command 401.
Recall the user set with Command 400. To recall the factory set, use command 200. If
the batteries have been discharged, these sets have been lost, and a fourth set will be
automatically loaded from ROM.
To perform a calibration, turn calibration ON with 100 COMM +. Then enter the
command number and press COMM again. Use SYMM/BORDER/CLIP controls and +-
to make changes. CLEAR when finished, and turn calibration OFF with 100 COMM - if
you want to prevent accidental recalibration.
Comm
Circuit
SYMM
BORDER
CLIP
101
BGR color
Null R-Y
Null B-Y
---
102
BDR color
Null R-Y
Null B-Y
---
103
DSK color
Null R-Y
Null B-Y
---
104
Wipe DC
Wipe size
---
---
105
Dac center
Offset
---
---
106
Black offset
Offset
---
---
107
Burst
Amplitude
PAL phase
NTSC phase
108
Circle
Patt 32
Pat 8 (H)
Pat 8 (V)
109
Horzizontal
Phase
---
Blank width
110
H ramp
Effects
Take
---
111
V ramp
Effects
Take
---
112
H 5x
5x horz freq
---
Pat 5 cross
113
V 5x
5x vert freq
---
---
114
Zero phase
BGR
BDR
DSK
115
Luminance
BGR
BDR
DSK
116
Saturation
BGR
BDR
DSK
117
Rotary wipes
pivot/closure
---
---
118
Take
bord size (n)
bord size (r)
---
119
H charge
Pat 57 (H)
Pat 57 (V)
Pat 59
120
V charge
Pat 58 (H)
Pat 58 (V)
Pat 60
121
Wipe
Eff bord n/r
---
Eff bord n/r
200 Reload original factory calibration.
400 Restore user calibration registers
401 Save user calibration registers
--- indicates that control has its normal function