background image

5

MS-40/MS-50 B

ACKPACK

 S

PRAYER

O

PERATOR

'

S

 M

ANUAL

A

SSEMBLY

 

AND

 M

AINTENANCE

1.

Remove all contents from box.

IMPORTANT
Lubricate felt washer assembly, gasket inside cap, and check valve
before initial use, and after each use.

2.

Unscrew tank cap and remove strainer. Apply a coating of 5 or 10
weight oil to the tank cap O-ring and check valve.

3.

With tank cap removed, disconnect the agitator (F) from the pump
module (D) inside the tank.

4.

Unscrew pump module cap (A) from the top of the tank.

5.

Lift pump module/cap out of tank.

6.

Slide cap off pump assembly. - Fig. 1

7.

Remove felt washer (B) from cap, and liberally oil by dipping in 5
or 10 weight oil. - Fig. 1

8.

Reassemble felt washer to inside of cap, and reinstall on tank.
When first contact of felt is made with tank lip, tighten one
additional half turn. Do not completely tighten at this time.

9.

Install pump module into tank through pump module cap assem-
bly, and tighten cap securely.

10.

Snap agitator into pump module groove, with paddle up.

11.

Locate the pump lever (C)  - Fig. 2 There are two (2) bends on one
end of the pump lever. This end is installed on the pump module.
- Fig. 3

12 .

Place one small washer on pump lever before installing on pump
module.

13.

Insert pump lever through opening on top of pump module.

14 .

Place second small washer on pump lever and secure lever
assembly with snap pin.

15 .

Insert pump handle through hole at base of the sprayer on pump
module side. Before installing handle completely, insert pump
lever (C) into bracket on pump handle (E). - Fig. 4

16.

Insert pump handle completely. Install small washer and snap pin
to secure pump handle to pump lever.

17.

Install large washer and snap pin to secure the pump handle at the
base. (The pump handle assembly is now complete.)

18.

Hook the plastic clips attached to the shoulder straps into the
openings at the base of the unit.

19 .

Attach spray wand to spray gun and firmly tighten.

B

A

C

D

E

F

C

Fig. 1

Fig. 2

Fig. 3

Fig. 4

E

C

Содержание MS-40

Страница 1: ...ayer Operator s Manual MODELS MS 40 MS 50 99922202847 10 01 WARNING DANGER Readrulesforsafeoperationandallinstructionscarefully ECHOprovidesthis Operator sManualwhichmustbereadandunderstoodforproperandsafeoperation ...

Страница 2: ...on but are subject to change without notice Illustrations may include optional equipment and accessories and may not include all standard equipment INTRODUCTION Welcome to the ECHO family This ECHO product was designed and manufactured to provide long life and on the job dependability Read and understand this manual You will find it easy to use and full of helpful operating tips and SAFETYmessages...

Страница 3: ...es when filling using and cleaning the sprayer Always wear a mask or respirator when filling using and cleaning sprayer if recommended by the spray material manufacturer Wear protective gear and clothing when filling using and cleaning the sprayer Always release pressure in the pump prior to filling cleaning or servicing the sprayer Before opening a container of pesticide or other spray material c...

Страница 4: ...E 0 4 9 G P M 0 4 9 G P M S TA N D A R D N O ZZL E F a n F a n P R E S S U R E R AT IN G 1 5 T O 1 6 8 P S I 1 5 to 1 6 8 P S I R E C O M M E N D E D A P P L IC AT IO N S C H L O R IN E B A S E X X F E R T IL IZE R S X X H E R B IC ID E S X X IN S E C T IC ID E S X X P E S T IC ID E S X X O IL B A S E D S P R AY X X S O LV E N T B A S E D S P R AY X X S TA IN S S E AL E R S X X D IS S O LVA B L E ...

Страница 5: ...to tank through pump module cap assem bly and tighten cap securely 10 Snap agitator into pump module groove with paddle up 11 Locate the pump lever C Fig 2 There are two 2 bends on one end of the pump lever This end is installed on the pump module Fig 3 12 Place one small washer on pump lever before installing on pump module 13 Insert pump lever through opening on top of pump module 14 Place secon...

Страница 6: ... 6 Always oil the gasket on the cap of the unit as well as the check valve This will extend the life of the seal and is important for obtaining a proper seal with no leaks 7 A unit that has been used with herbicides should never be used to spray insecticides unless the sprayer has been properly cleaned and all other chemicals neutralized Failure to do this could cause you to kill plants that have ...

Страница 7: ...vacuum Take the cap off clean vent hole clean the check valve oil valve and re install TROUBLESHOOTING PROBLEM When you squeeze the trigger on the spray gun it sticks and is slow in returning to the shut off position when you release the trigger The pin in the spray pistol sticks when pushed When you release the trigger the pin does not come back up to shut off the flow The sprayer will not pressu...

Страница 8: ...ntenance of this product you may call the ECHO ConsumerProductSupportDepartmentat1 800 673 1558from8 30am to 4 30 pm Central Standard Time Monday through Friday Before calling please know the model and serial number of your unit to help your Consumer Product Support Representative WARRANTY REGISTRATION You may register your Echo equipment using the warranty registration card or register on line at...

Отзывы: