6.
Remove plug (G) and check
level of grease. Grease should
fill gear case to bottom of
grease plug hole.
7.
Add grease if necessary using
squeeze-type tube. Do not use
high pressure grease gun. DO
NOT over-fill.
8.
Install inner blade adapter (B)
onto PTO shaft (C).
9.
Install and center new blade (F)
onto inner fixing plate (B), with
longest side toward shield.
10. Install outer fixing plate (E) and
nut (D). Tighten left hand
threaded nut (D) firmly,
counterclockwise.
Note: Never reuse old split pin.
11. Install new split pin (A) to
secure nut.