Echelon i.LON SmartServer Скачать руководство пользователя страница 12

 

Assembling the SmartServer Hardware  

Assembly Overview 

You need to assemble the SmartServer and connect it to a TCP/IP network before you can configure it 
and begin using its embedded applications.  This section lists the general steps required to assemble 
and connect the SmartServer.  These steps are then detailed in the referenced sections. 

1.

 

Mount the SmartServer inside a suitable enclosure.  For more information on this step, see the 
next section, 

Mounting the SmartServer

.  

2.

 

Connect the screw terminals on the SmartServer.   

a.

 

You must connect the power screw terminals for all SmartServer models as described in the 

Power Supply

 section in this chapter.   

b.

 

If you are assembling an FT-10 model of the SmartServer, you must connect a L

ON

W

ORKS

 

FT-10 channel to the LON A

®

/PLT + and LON B

®

/PLT - screw terminals on the hardware 

(screw terminals 18 and 17).  For more information, see 

L

ON

W

ORKS 

 Network 

in this chapter. 

If you are assembling the PL-20 model of the SmartServer with the external coupling option 
(Model 72103R-420), you can connect twisted pair wiring between screw terminals 17 and 18 
and a single-phase or three-phase external coupler.  For more information, see 

L

ON

W

ORKS 

 

Network 

in this chapter.  All other PL-20 models of the SmartServer communicate through the 

power supply and therefore do not require any additional connections.   

c.

 

Optionally, you can connect the screw terminals for the RS-232/RS-485 serial ports, digital 
outputs, pulse meter inputs, digital inputs, and +12V <20mA output on the hardware as 
described in the respective sections in this chapter for each of these connections.   

3.

 

Connect the Ethernet port on the SmartServer.  Connect one end of an Ethernet cable to the 
Ethernet port on the SmartServer, and then connect the other end to an Ethernet hub or switch that 
can communicate with your computer (TCP/IP network).  The Ethernet port on the SmartServer is 
auto-switching; therefore, you can use a straight-through or crossover Ethernet cable.  For more 
information on this step, see 

Connecting the Ethernet Port 

in this chapter. 

4.

 

Optionally, you can connect the console port on the SmartServer.  Connect one end of a RS-232 
null modem cable to the console port on the SmartServer, and then connect the other end to one of 
the COM ports on your computer.  You can then use a terminal emulation program such as 
Windows HyperTerminal on your computer to access the SmartServer’s console application and 
configure the SmartServer.  The default communication properties for the SmartServer are 

9600

-

 

8-None

-

1

-

None

.  Note that you should use the SmartServer’s built-in Web pages to configure the 

SmartServer whenever possible.  For more information on this step, see 

Connecting the Console 

Port 

in this chapter. 

5.

 

If you are assembling a SmartServer that has a built-in analog modem, connect the telephone port 
on the SmartServer.  For more information on this step, see 

Connecting the Telephone Line Port

 in 

this chapter. 

6.

 

Apply power to the SmartServer.  For more information on this step, see 

Applying Power to the 

SmartServer 

in this chapter. 

7.

 

Connect your SmartServer to a TCP/IP network. 

a.

 

If your computer is not on the subnet as your SmartServer, open a command prompt and type 
the following command (change “192.168.1.0” to the appropriate prefix for your subnet):

 

route add 192.168.1.0 mask 255.255.255.0 %computername% 

Note

: If you are running Windows Vista™ on your computer, you need to open the command 

prompt with administrator privileges.  To do this, click 

Start

, type 

cmd

 in the search box, 

right-click the 

cmd.exe

, and then select 

Run as Administrator

.  If you receive a “The 

parameter is incorrect” error after entering the route command, replace 

%computername%

 

with the IP address of your computer.  

Содержание i.LON SmartServer

Страница 1: ...i LON SmartServer Hardware Guide C o r p o r a t i o n 078 0346 01B...

Страница 2: ...lon and referenced in this document have been described for illustrative purposes only and may not have been tested by Echelon It is the responsibility of the customer to determine the suitability of...

Страница 3: ...Preface The i LON SmartServer is a low cost high performance controller network manager router remote network interface and Web server that you can use to connect LONWORKS Modbus and M Bus devices to...

Страница 4: ...by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit dif...

Страница 5: ...100 BaseT Ethernet port You can also connect models of the SmartServer that have built in 56K V 90 analog modems to TCP IP networks using their RJ 11 telephone line ports and a dial out connection Op...

Страница 6: ...this DVD contains the installation software for the following support products that are required to run the i LON SmartServer software LNS 3 Service Pack 8 Update 2 LonMaker 3 1 Service Pack 3 Update...

Страница 7: ...ow to configure the SmartServer and use its applications to manage control networks i LON SmartServer Powerline Repeating Network Management Guide Describes how to install a PL 20 repeating network an...

Страница 8: ...ion about the SmartServer at the i LON Web page at www echelon com ilon If you have technical questions that are not answered by the SmartServer documentation SmartServer online help or i LON Web page...

Страница 9: ...support echelon co jp China Chinese English Echelon Greater China Rm 1007 1008 IBM Tower Pacific Century Place 2A Gong Ti Bei Lu Chaoyang District Beijing 100027 China Phone 86 10 6539 3750 Fax 86 106...

Страница 10: ...ts x 1 Assembling the SmartServer Hardware 1 Assembly Overview 2 Mounting the SmartServer 3 Wiring the SmartServer Connections 5 Connecting the Screw Terminals 6 Power Supply 6 LONWORKS Network 9 RS 2...

Страница 11: ...Server hardware inside a suitable enclosure It describes how to connect the SmartServer hardware to a power supply LONWORKS FT 10 and PL 20 channels digital input digital output and pulse meter input...

Страница 12: ...to an Ethernet hub or switch that can communicate with your computer TCP IP network The Ethernet port on the SmartServer is auto switching therefore you can use a straight through or crossover Ethern...

Страница 13: ...ved enclosure that is mounted in a restricted access area High voltage wiring must be performed only by a qualified service person The SmartServer mounts to a 35mm x 7 5mm or 35mm x 15mm DIN rail The...

Страница 14: ...4 Assembling the SmartServer Hardware...

Страница 15: ...ports digital outputs pulse meter inputs digital inputs and the 12V 20mA output After you connect the screw terminals you should use an Ethernet cable to connect the Ethernet port on the SmartServer...

Страница 16: ...hould be stripped to a length of 7mm 0 28 Optionally you can use a soldering iron to tin the stripped lengths of any stranded wires to prevent fraying and inadvertent contact with adjacent terminals T...

Страница 17: ...is also used for LONWORKS network communication for the PL 20 models of the SmartServer The SmartServer contains an auto ranging auto setting mains power supply You do not need to adjust any jumpers...

Страница 18: ...the range 100 240VAC 10 to 30 50 60Hz 2 5Hz Alerta de Seguridad y Alto Voltaje Aseg rese que la la red electrica de corriente alterna AC este DESENERGIZADA antes de quitar la cubierta manipular los ca...

Страница 19: ...LONWORKS channel The TP FT 10 interface is polarity insensitive and requires connecting the twisted pair to terminals 17 18 You can also use screw terminals 17 18 on the PL 20 model of the SmartServe...

Страница 20: ...e that the RS 232 serial port supports only one of the aforementioned items at a time The RS 485 bus connection is implemented on screw terminals 25 28 These connections are polarity sensitive termina...

Страница 21: ...ield 27 RT RS 485 28 RT RS 485 Connecting an External GSM Modem to the RS 232 Serial Port You can connect an external GSM modem to your SmartServer using the RS 232 serial port To do this you need to...

Страница 22: ...to the SmartServer using the RS 232 and RS 485 serial ports For more information on the Modbus protocol go to www modbus org Connecting Devices to the RS 232 and RS 485 Serial Ports with FPM Drivers Y...

Страница 23: ...e location of the relay output screw terminals on the SmartServer The following table lists the enclosure markings for the relay output screw terminals on the SmartServer and their connection type Scr...

Страница 24: ...tween its positive and negative connections is closed the voltage is 0 for 30ms or longer The circuit must be open for a minimum of 30ms between pulses See Chapter 9 of the i LON SmartServer User s Gu...

Страница 25: ...nnot reverse the polarity of the digital inputs because it will cause improper operation of the monitoring circuits Each of the digital inputs is controlled by a Digital Input application on the Smart...

Страница 26: ...on between screw terminals 16 and 20 does not include screw terminal 19 as it is connected to the active device 12V 20mA Output The SmartServer contains one 12VDC outlet that can provide up to 20mA Th...

Страница 27: ...minate the LAN 100 LED indicator if a 100BaseT network connection has been established The SmartServer automatically detects whether it is connected to an Ethernet hub or switch or directly to a compu...

Страница 28: ...s minimizes the risk of shock or damage should lightning strike on or near a telephone circuit to which the SmartServer is connected For SmartServer models 72102 which contain a 56K V 90 analog modem...

Страница 29: ...have mounted the SmartServer connected all the wiring and closed the enclosure you can apply power to the SmartServer The LEDs on the SmartServer will flash for several minutes as the unit boots Once...

Страница 30: ...20 Assembling the SmartServer Hardware...

Страница 31: ...i LON SmartServer Hardware Guide 21 2 Using the SmartServer LEDs and Service Buttons This chapter describes how to use the LEDs and service buttons on the SmartServer hardware...

Страница 32: ...nput LEDs which are labeled 1 and 2 The Input 1 and Input 2 LEDs light when an ON value is received on the Digital Input 1 and Digital Input 2 inputs respectively The LEDs respond appropriately when t...

Страница 33: ...to reboot the SmartServer The following figure and table display and describes these buttons Service Pin Sends a LONWORKS service pin message to the LONWORKS channel on which the SmartServer is attach...

Страница 34: ...OK and then click OK in the dialog that appears to confirm the reboot To reboot your SmartServer using the console application enter the reboot command For more information on using the SmartServer We...

Отзывы: