ECH2O Tec. BEACH HOUSE Series Скачать руководство пользователя страница 15

HIGH PRESSURE PUMP SYSTEM  

TROUBLESHOOTING GUIDE 

 
 

MALFUNCTION 

 

CAUSE 

 

 

 

REMEDY

    

 

 
The pressure drops 

 

Broken valve spring 

 

 

Replace spring 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fouled inlet strainer  

 

 

Clean strainer 

 

 

 

 

Fouled pre-filter(s) 

 

 

Replace filter cartridge(s) 

Cavitation  (Noisy operation) 

 

Check suction lines for  

 

 

 

 

 

Restrictions 

Air in system   

 

 

Check suction lines for leaks 

 

 
Water in crankcase 

 

High humidity   

 

 

Reduce oil change interval 

 

 

 

 

Cracked ceramic plunger/s 

 

Replace ceramic plunger/s 

 
 
Noisy operating  

 

Worn bearings    

 

 

Replace bearings, refill crankcase 

 

 

 

 

 

 

 

 

 

with recommended lubricant 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cavitation 

 

 

 

Check inlet lines for restrictions 

 

 

 

 

 

 

 

 

 

Check strainer and filter(s) 

 
 
Inability to 

 

 

Discharge valve chamber 

 

Allow more time to prime  

build up pressure 

 

has air trapped within it  

 

and ensure that there are no  

 

 

 

 

 

 

 

 

 

air suction leaks. 

 

 

 

 

 

 

 

 

 

Open valve chambers and allow  

 

 

 

 

 

 

 

 

 

air to escape 

 
 
Rough/Pulsating 

 

 

 

 

 

 

Check system for stoppage or 

 

operation with   

 

 

 

 

 

 

air suction leaks  

pressure drop   

 

 

 

 

 

 

 

 

 

 

Cavitation 

 

 

 

Check inlet lines for restrictions 

 

 

 

 

 
 
Excessive  

 

 

Worn plunger(s) 

 

 

Replace plunger(s)  

leakage between 

 

Worn seals 

 

 

 

Replace seals 

the high pressure 

 

 

 

pump manifold   

 

Cracked plunger(s) 

 

 

Replace plunger(s) 

and rear crankcase 

 

 

 

section  
 
 
High crankcase  

 

Wrong grade of oil  

 

 

Use specified type of oil. 

temperature 

 

 

Improper amount of oil in crankcase 

Adjust oil level to proper  

 

 

 

 

 

 

 

 

 

amount 

Содержание BEACH HOUSE Series

Страница 1: ...LATION LAYOUT 6 7 INSTALLATION INSTRUCTIONS 8 9 OPERATION INSTRUCTIONS 10 MEMBRANE CLEANING PROCEDURE 11 MAINTENANCE TIMETABLE 12 PRESSURE VESSEL ENDPLUG CHANGING PROCEDURE 13 ELECTRICAL DIAGRAM 14 TR...

Страница 2: ...familiar with each component of your new ECHO Tec desalination system By understanding the function importance and normal operation of each part in the system the operator can readily diagnose proble...

Страница 3: ...l and expected RO MEMBRANE TYPE Standard size high rejection TFC Polyamide thin film composite spiral wound single pass reverse osmosis element SALT REJECTION min 99 5 SALINITY RANGE up to 50 000 ppm...

Страница 4: ...fittings 1 Stainless steel bracket with 8 screws 5 20 feet 6 meter 1 2 reinforced vinyl hose reject product flush 10 feet 3 meter blue product water tubing membrane to flow panel 10 feet 3 meter 3 4 r...

Страница 5: ...WATER LEVEL AT LOW TIDE Beach House Series Installation Layout Product Max 2 7m 9ft Max 9m 30ft Reject Non return valve Sea strainer...

Страница 6: ...reservative under best conditions is one year We recommend you install and use your watermaker as soon as possible When all other components and hoses pipes are completely assembled remove the caps on...

Страница 7: ...eeded Run the second high pressure hose from the flow control box to the O ring sealed fitting at the end of the membrane that is market OUT CAUTION WHEN CONNECTING THE HIGH PRESSURE HOSE TO THE MEMBR...

Страница 8: ...ake system until all entrapped air has escaped then switch the selector switch Off and bring the selector switch in the Auto position 4 Press the start button for about five seconds If the motor stops...

Страница 9: ...STORAGE PROCEDURE If you intend to store your watermaker for more than ten days growth of microorganism will degrade the RO membranes performance The RO membranes should be flushed with a biocide solu...

Страница 10: ...on label CAUTION Do not mix different cleaning chemicals together Do not use different cleaning chemicals together at the same time Mix the cleaning chemicals separately and use them separately Note...

Страница 11: ...months High pressure pump Change crankcase oil Change packings seals and O rings Initial change after 50 hrs Every 200 operating hours or 6 months Every 5000 hrs or when leaking R O membrane When pro...

Страница 12: ...s inner wall and remove it in one fast pull 6 Inspect the end plug for hairline cracks or damages on the O rings and O ring grooves 7 Pull the membrane on the product pipe out of the pressure vessel o...

Страница 13: ...TRANS FORMER START SWITCH S1 PUSH BUTTON NO SELECTOR SWITCH S2 3 POSITION MAINT 4 CONTACTS NO T1 HIGH PRESS SWITCH S4 NC LOW PRESS SWITCH S5 NO TANK FULL SWITCH S6 NC EXTERNAL MAIN IN ELECTRICAL DIAG...

Страница 14: ...Plunger 18mm 24 203401 Washer plunger rod 25 203000 Nut plunger rod 26 660053 Seal retainer 3 3 3 3 3 ETP 02 3 37 103042 Valve 38 701002 O ring valve cap 39 520057 Valve plug 40 203510 Washer ribbed...

Страница 15: ...tation Check inlet lines for restrictions Check strainer and filter s Inability to Discharge valve chamber Allow more time to prime build up pressure has air trapped within it and ensure that there ar...

Страница 16: ...ned to Echo Marine s Service Center The purchaser must pay any transportation or labor expenses incurred in removing and returning the product to the service center The limited warranty does not exten...

Страница 17: ...ranteed against iron fouling rust chemical attack extreme temperatures over 113 F under 33 F drying out or extreme pressures over 1000 psig CAUTION Use of parts not supplied directly by Echo Marine ge...

Отзывы: